INTRODUCTION
This manual has been compiled by the Hardware Section, Building Materials Branch of the War Production Board, in collaboration with the National Bureau of Standards and a seven-man industry committee composed of outstanding builders’ hardware manufacturers. Its purpose is to eliminate, through the control of installation, as provided from time to time in directives of the War Production Board, every possible ounce of scarce materials and every item which is not strictly necessary, consistent with a reasonable degree of service.
The provisions contained in the manual are designed specifically for certain types of buildings. It is intended, however, that the use of builders’ hardware in buildings, not specifically named herein, shall conform to the provisions provided for buildings of a similar type. The specific types of buildings for which provision has been included are as follows:
Part I.—Public type buildings including administrative? office, and monumental buildings; auditorium and recreation buildings; communications buildings; dormitories and nurses’ homes; education buildings and laboratories ; hospital, dispensary, and infirmary buildings; and waterworks and sewage disposal plant buildings.
Part II.—Residential housing.
Part III.—Cantonments and similar type buildings.
Part IV.—Industrial type buildings and buildings for Army and Navy bases other than previously covered in part III, including assembly explosive loading, packing, screening, detonator loading, pelleting, magazine, powder buildings ; blending, mixing buildings; tracer and nigh-explosive press-loading buildings; tracer, igniter and incendiary buildings; melting and pouring buildings; drilling and thread-cleaning buildings; percussion element line buildings; preliminary dry houses, change buildings ; ordnance and factory buildings ; powerhouse, warehouses, fire house, pump house, and shipping-room puildings; office, administration, instruction, first-aid buildings; guard louses, etc., officers’ quarters, and cafeteria buildings.
GENERAL PROVISIONS
This manual is based upon the critical positions, at the time of issuance, of materials used in the production of hardware. It has been designed to correlate all orders and restrictions which affect the
(1)
2
production or use of builders’ hardware. The manual is subject to revision by the Director of Industry Operations whenever warranted by a change in the critical position of the materials involved, or by the issuance of further orders or restrictions affecting builders’ hardware.
SUBSTITUTES
Whenever the use of this manual is made a requirement of construction by direction of any Federal agency, the items, and quantities of items, provided for are to be considered as maximum. Anyone desiring to use smaller sizes or lesser quantities may do so notwithstanding provisions of this manual.
Materials or products of the sizes, weights, or composition specified in the manual, may not be immediately procurable due to necessary changes in manufacturing processes or procedure. In such cases, similar products or materials, previously produced for the same use, may be substituted, provided such products or materials are obtainable from a supplier’s existing stocks or inventory.
HOUSING PROVISIONS
The provisions contained in this manual with respect to builder’s hardware in housing have been adopted from the War Housing Critical List effective February 24, 1942. Any amendments to this List shall take precedence over the housing provisions of this manual, until such time as the manual can be amended to conform.
APPLICABILITY OF ORDERS
Any orders or regulations of the War Production Board, the terms of which are more stringent, shall take precedence over the provisions of this manual.
PART I.—PUBLIC TYPE BUILDINGS
SECTION A. GENERAL
A-l. Type numbers.—Hardware items, unless otherwise described herein, are designated by type number selected from the applicable Federal specifications listed below, except as modified herein:
FF-H-106, Hardware, builders’; locks and lock-trim.
FF-H-111, Hardware, builders’; shelf, and miscellaneous.
FF-H-116b, Hardware, builders’; hinges (nontemplate).
FFH-121a, Hardware, builders’; door closers.
FF-H-136, Hardware and fittings; lavatory partitions and enclosures.
FF-P-lOla, Padlocks.
A-2. Finishes'permitted for iron and steel.—The finishes for iron and steel hardware covered by this schedule shall be limited to the following:
(1)	For all items other than door closers and butts—US18A, except where finish USP or japan finishes (US IB or US ID) or unfinished work is specified.
(2)	For butts—USP, except where finish US 18A or japan finishes (US IB or US ID) or unfinished work is specified. Butts finished US18A may be unsanded.
(3)	For door closers—black paint or lacquer finish, except where finish USP is specified.
A-3. Materials.—Where Federal specifications or other type numbers indicate or specify brass or bronze material, such items must be furnished in wrought steel, cast iron, or malleable iron. Brass may be used for essential interior parts, cylinder assemblies, and keys of cylinder locks only. Cylinder padlocks may have brass or zinc die-cast mechanism. Case and shackle may be of steel, cast iron, or malleable iron. Ferrous parts of padlocks may be zinc coated.
A-4. Feys.—Bit key locks shall have one only key for each lock. Locks and latches having cylinders, and padlocks, shall have two only keys for each lock. Only three master keys may be furnished with each group of locks when such locks are required to be furnished master-keyed.
A-5. Strikes shall be flat type without boxes.
A-6. Alternate lock trim.—The lock trim (knobs, roses, and escutcheons) required under this limitation is of cast metal. Where wrought-metal trim is desired, type numbers for knobs, roses, and escutcheons under requirements for the various doors may be changed as follows:
Knobs 210, change to 210B.
Roses 330A, change to 330.
Escutcheons, 350A, change to 350.
(3)
4
A-7. For Doors—1% inches thick—escutcheons of elongated or pendant design may be used for mortise locks and latches in lieu of roses.
A-8. Alternate locks and latches for interior doors.—Cylindrical case locks and latches of “heavy duty” Schlage type “C” with case “D” may be substituted for locks and latches, specified herein for interior doors, provided that the cylindrical case locks and latches are designed and constructed so as to give same performance in operation and control as corresponding locks specified. Cylindrical case locks and latches must comply with Federal Specification FF-H-106.
A-9. Door stops shall be wood.
A-10. Surface door closers may be types 3001, 3003, 3004, or 3006. Where butts are less than 6 inches from intersecting wall or partition, the closer may have a Soffit bracket. Size of closer shall be not larger than as indicated in table on page 4 of Specification FF-H-21a. Where surface door closers with hold-open arms are shown in the limitations, a door-holder type B-1149 may be used in lieu of hold-open feature. Where surface door closers with hold-open feature are required on underwriters’ label fire doors, a closer, bearing underwriters’ label, with automatic fusible link release mechanism may be furnished—subject to Steel Conservation Order M-126 and amendments thereto.
A-ll. Surface overhead door holders may be ferrous metal with encased automatic engagement, release action, and shock absorber, and may have adjustable sliding tension hold-open feature, sliding in a channel and engaging when the door is open at 90° to .95°, and with control knob in the end of the channel for disengaged position. Where a small door holder is desired type B-1149, as covered by Federal Specification E-FF-H-111, may be used.
Note.—Where floor-type door holders are required, Type C-1149A may be used in lieu of the surface overhead type.
A-12. Coat and hat hooks shall be omitted.
A-13. Butts and hinges.—Doors 7 feet or less in height may have not more than two butts or hinges, size as required, and for greater height one additional butt or hinge for each additional 2% feet or fraction thereof. Except that doors 6 feet or more in height, and all doors exceeding 3 feet 4 inches in width may have three butts. Size of butt shall be not larger than as indicated for various doors in table I below:
Table I.—Rule for size of butt hinges
Thickness in inches	Width of doors in inches	Height of butt hinges in inches	
% to 1% cabinet doors	‘	 % to l}i screen or combination doors	 1% doors	 1% doors	 2, 2#, and 2% doors	 1%, and 1% transoms and casements	 2, 2%, and 2# transoms and casements		(To 36	 < Over 36 to 40	 [Over 40			2H. ■ 3. 3& 4. 4& 5. 5, extra heavy. 3. 3%.	
5
Cast-iron butts may be substituted for the butts listed, as follows:
Wrought butt listed :	Comparable cast butt
2014%P_______________________________■___160 BT primed for paint, or 040.
2015_____________________________________160.
2015%_____________________________-______160BT, unpolished.
2029B____________________________________162 unpolished.
2G31A____________________________________G160 BT.
2010__________—__________________________ 161%.
2010%P____________________________:______161% BT, primed for paint
2061_____________________________________152.
2080%P___________________________________169.
Note.—In the above comparative list, Nos. 160, G160, 152, 169, 161%, and 040 are from the catalog of P. & F. Corbin. Butts of other manufacture having the same general design and of approximately the same weight may be used.
A-13a. 'Where spring hinges are required, proper sizes must be taken from table under type 2330, FF-H-116b, except where sizes are limited herein.
A-13b. Checking -floor hinges where required for single-acting doors must be type 3520A. On double-acting doors, they must be type 3500 or 3510. Size shall be not larger than as indicated for size oi door in Federal Specifications FF-H-121a. On single-acting and doubleacting doors, overhead concealed closers may be substituted for checking floor hinges.
A-14. Counter gates, single-acting, each to have:
1 pair hinges, type 2331A, size as required.
A-15. Counter gates, double-acting, each to have:
1 pair hinges, type 2330A. size as required.
1 secret gate latch, type A1187, except double-acting.
A-16. Cabinets, single and pairs doors.—
1 pair butts, type 2018^.
1 only elbow catch, type 1079 (for pairs doors only).
1 only knob pull, type A1283 (1 to each door).
1 only friction catch.
Note.—Where cabinets are required to be locked, 1 only lock, type 701A, one to each single and pairs doors may be used in addition to above.
1 drawer pull, type 1296, or bar-type pull of glass or plastic. Where drawers are required to be locked, 1 only lock 655A, one to each drawer may be used in addition to above.
A-17. Transoms, and bottom-hinged sash, each to have:
1 pair butts, type 2029B.
1 only transom catch, type 1097.
2 only transom chains, type 1120A.
Note.—Transom lifts, type 1198G or type 1198K, as required may be substituted for transom catch 1097 and chains 1120A. If transom lift is substituted, catch and chains must be omitted.
A-18. Pivoted sash, each to have:
1 set pivots, type 1115A.
1 only transom catch, type 1097.
A-19. Double-hung windows, each to have:
1 only sash lock, type 1139 (except tumbled finish).
1	only sash lift, type 1201A (except tumbled finish). (On sash over 18 inches two lifts may be furnished.)
6
Sash balances must be of single coiled-spring (clock spring) type with suspension taps, or twin coiled-spring “flat” type with suspension cables, or single helical-spring “vertical” type with tubular housing. Springs may be high-carbon steel uniformly tempered. Suspension tapes and cables may be coated with zinc. The single coiled-spring type must have pressed-steel or cast-iron case and front for mounting in mortise in window frame. The twin coiled-spring type must have a pressed-steel case for mounting flatwise in cut-out in window frame. For each pair of sash, two pairs of balances with single spring or one pair of balances, with twin spring may be furnished, except for 1% inches sash not over 2 feet 10y2 inches wide, or with glass not over 30 inches wide, one pair of balances with single spring or one twin-spring balance shall be furnished, for each pair of sash, provided a suitable equalizer for each sash is furnished.
A-20. Casement windows, each to have.
Butts, type 2015^ (for casement opening out, type 2031A).
2	only surface bolts, type 1060, 6-inch (for pairs Casements only).
1	only casement fastener, Yale & Towne 1067 or equal, with wrought or cast base.
1	only casement adjuster, type 1002 A (1 to each sash). Two steel casement pivots as described below may be used in lieu of butts and casement adjuster. Pivot may consist of sill plate, sash plate, arm and sliding shoe, as manufactured by Vincent Whitney Go., or equal.
A-21. Small-size access doors, each to have:
1	pair butts, type 2018^.
1	cabinet lock, type 701A.
A-22. Scuttleseach to have:
1	pair hinges No. 2240.
1	only scuttle fastener, type A1148, except japanned.
A-23. Outside window wire grilles.—
1	only padlock Id or 11) with chain as for Id, size 1% inches. A-24. Window screens, each to have:
1	pair screen hangers, type 1825 or 1825B, except japanned.
1	hook-and-eye type 1601C, 1% inch, except japanned.
A-25. Screen doors, each to have:
1	pair butts, 2031A.
2	only surface bolts, 1060, 6-irich (pairs of doors only).
1	catch, type 1086A.
A-26. Sliding, f olding, partition doors.—Hardware may be similar to Richards-Wilcox folding partition door hardware 237, complete with track, hangers, brackets, floor guide, track stops, butts, bolts, etc. Locksets may be only type 97 x knob 210 x rose 330A x cast flush cup. approximately 3 inches in diameter with drop ring.
7
A-27. W ater-closet stall doors, each to have: where metal partitions are used, this paragraph is not needed.
(a) Partitions without hanging stile:
1	set of hinges (1 only hinge, type 4102; 1 only hinge, type 4102A).
1 strike, type 4315.
1	bolt, type C1051.
(5)	Partitions with hanging stile:
1	set of hinges (1 only hinge, type 4101; and 1 only hinge, type 4101A).
1	latch and strike with keeper, type 4301A.
(c) Wood partitions:
1	pair spring hinges* type 2302.
1	latch, type 4301, without keeper.
1	strike with keeper similar to Chicago Spring Hinge Co.’s type 1345C.
A-28. Push plates must be either beveled glass or plastic.
SECTION B. ADMINISTRATIVE, OFFICE, AND MONUMENTAL BUILDINGS
B-l. The following requirements apply to administrative, office, monumental, and similar-type buildings. See also section A.
B—2. Pairs exterior entrance doors, each to have:
Butts, type 201014». If single-acting floor hinges are required in lieu of butts and door closers, two floor hinges, type 3520A, size as indicated may be used. Butts, door closers, and brackets must be omitted.
1	dead lock, type 115.
2	flush bolts, type 1044B.
2	surface door closers.
2	door pulls, type 452.
2	push plates, type 461, approximate size 14 x 3^ inches, glass or plastic.
B-3. Single exterior entrance doors, each to have:
Butts, type 2010^. If single-acting floor hinges are required in lieu of butts and door closers, one floor hinge, type 3520A size as indicated in proper table may be used.
Butts, door closers, and brackets must be omitted.
1	dead lock, type 115.
1	surface door closer.
1	door pull, type 452.
1	push plate, type 461, approximate size 14 x 3*4 inches, glass or plastic.
B-4. Single or pairs vestibule and stair hall doors, each to have: Butts, type 20101/2. If single-acting floor hinges are required in lieu of butts, floor hinges, type 3520A size as indicated in proper table may be used. Butts and door closers must be omitted.
1	surface door closer.
492930°—42----------2
8
1	push plate, type 461, approximate size 14 x 3% inches, glass or plastic.
1	door pull, type 452.
B	-5. Single doors to, or from toilets, toilet vestibules, locker and shower rooms, each to have:
Butts, type 2010%.
1	push plate, type 461, approximate size 14 x 3% inches, glass or. plastic.
1	door pull, type 452.
1	surface door closer.
1	door stop as limited.
B-6. Single doors to, or from private toilets and lavatories, each door to have:
Butts, type 2015%.
1 set locks, type 17A x knobs 210 x rose 330A x escutcheon 350A x turn knob.
1 door stop as limited.
B-7. Single doors corridor and ante rooms to, or from offices, conference rooms, etc., each to have:
Butts, type 2010%.
1 set locks, type 97 x knobs 210 x rose 330A
1 door stop as limited.
B-8. Single communicating doors between offices, each to have: Butts, type 2015%.
1	set locks, type 20 x knobs 210 x rose 330A x two turn knobs.
1 door stop as limited.
B-9. Single doors to, or from storage, machine rooms, shops and equipment room, each to have:
Butts, type 2010%, type 2015%.for storage rooms.
1 set locks 97 x knobs 210 x rose 330A.
1 door stop as limited.
B-10. Single doors from closets, slop sinks, pipe shaft, equipment panel doors, access doors, etc., each door to have:
Butts, type 2015%.
1 set latches, type 28 x knobs 210 x rose 330A.
If it is required to equip these doors with cylinder locks, in addition to above, 1 only dead lock, type 114 x no turn knob may be used.
1 door stop as limited.
B-ll. Single double-acting doors, each to have:
1 set floor hinges, type 3500 or 3510, size as required.
If jamb double acting hinges are required in lieu of floor hinges, 1 pair hinges 2330A may be used.
1 dead lock, type 115.
2 push plates, type 461, approximate size 14 x 3% inches glass or plastic.
B-12. All other single interior doors not otherwise covered, each door to have:
1	pair butts, type 2015%.
1	set locks, type 97 x knobs 210 x rose 330A.
1	door stop as limited.
9
SECTION C. AUDITORIUM AND RECREATION BUILDINGS
C-l. The following requirements apply to auditorium, recreation, and similar type buildings. See also section A.
C-2. Pairs, main entrance doors, each pair to have:
Butts, type 2010%.
1	set fire exit bolts, J5391L—active door, J5344L—inactive door Sargent & Co. catalog, or equal.
2	only surface door closers.
C-3. Single, main entrance doors, each door to have:
Butts, type 2010%.
1	set fire exisit bolts, J5391L Sargent & Co., catalog or equal.
1	surface door closer.
C-4. Pairs, exit doors from corridors, assembly halls or auditorium,, each pair to have:
Butts, type 2010%.
1	fire exit bolt, J5344L (each leaf) Sargent & Co. catalog, or equal.
C	-5. Other single exterior doors, each door to have:
Butts, type 2010%.
1	set locks, type 97 x knobs 210 x rose 330A.
1	surface door closer.
C-6. Single, or pairs doors, vestibule, stair hall, public toilets, toilet vestibule, locker and shower-room doors, doors in corridor or passageway from assembly halls, auditorium, recreation room, dining rooms and kitchens, each door to have:
Butts, 2010%.
1 push plate, size approximately 14 x 3% inches, glass or plastic.
1 surface door closer.
1 door stop as limited.
1 door pull 452.
C-7. Single doors to or from machine, furnace, equipment rooms, kitchens, each door to have:
Butts, 2010%.
1 set locks, 97 x knobs 210 x rose 330A.
1 door stop as limited.
C-8. Single doors to or from offices, storage rooms, each door to have:
Butts, 2015%.
1 set locks, type 97 x knobs 210 x rose 330A.
1 door stop as limited.
C-9. Single doors to or from private toilets, each door to have: Butts 2015%.
1	set locks, type 17A x knobs 210 x rose 330A x escutcheon 350A x turn knob.
I door stop as limited.
C-10. Single doors, to or from closets, slop sinks, pipe shaft doors, each to have:
Butts 2015%.
1	set latches, type 28 x knobs 210 x rose 330A. If it is required for these openings to be locked, in addition to above, 1 only dead lock 114 no turn knobs may be used.
1	door stop as limited.
10
C-ll. Single doors double acting, each door to have:
1 set D. A. floor hinges, type 3500 or 3510, size as limited in proper table.
Note.—Double acting jamb spring hinges may be substituted in lieu of above hinges.
1	pair spring hinges, type 2330A may be used.
2	push plates approximately 14 x 3% inches glass or plastic.
1	dead lock type 115.
C-12. Other single interior doors not otherwise covered, each door to have:
Butts 20151/2-
1	set locks type 97 x knobs 210 x rose 330A.
1	door stop as limited.
SECTION D. COMMUNICATIONS BUILDINGS
D-l. The following requirements apply to communications and similar type buildings. See also section A.
D-2. Pairs exterior entrance doors, each pair to have:
Butts, type 2010%.
Note.—If single-acting floor hinges are required in lieu of butts and door closers, 2 floor hinges type 3520A, size as indicated in proper table may be used. Butts, door closers, and brackets must be omitted.
1	dead lock type 115.
2	flush bolts, type 1044B.
2	door pulls, type 452.
2	push plates, type 461, approximately 14 x 13% inches glass or plastic.
2	surface door closers.
D-3. Single exterior entrance doors, each door to have:
Butts, 2010%.
Note.—If single-acting floor hinges are required in lieu of butts and door closers, 1 floor hinge, type 3520A, size as indicated in proper table may be used. Butts, door closer, and brackets must be omitted.
1	dead lock type 115.
1	surface door closer.
1	door pull, type 452.
1	push plate, type 461, approximate size 14 x 3% inches, glass or plastic.
D-4. Exterior doors electrically controlled, each door to have: Butts, 2010%.
Lock, type 800 x 2 cylinders x 2 handles 420 x electric strike of suitable voltage.
2	bolts, type 1044B for pairs of doors.
1	surface door closer.
D-5. Single or pairs of vestibule and stair hall doors, each door to have:
Butts, 2010%.
Note.—If single-acting floor hinges are required tn lieu of butts and door closets, floor hinges type 3520A, size as Indicated in proper table may be used. Butts and door closers must be omitted.	a
11
1 surface door closer.
1 push plate, type 461, approximate size 14 x 3% inches, glass or plastic.
1 door pull, type 452.
1 door stop as limited.
D-6. Single doors to or from toilets, toilet vestibules, locker and shower rooms, each door to have:
Butts, type 2010%.
1 door pull, type 452.
1	push plate, type 461, approximate size 14 x 3% inches, glass or plastic.
1 surface door closer.
1 door stop as limited.
D-7. Single doors to or from private toilets and lavatories, each door to have:
Butts, type 2015%.
1 set locks, type 17A x knobs 210 x rose 330A x escutcheon 350A x turn knob.
1 door stop as limited.
D-8. Single doors {interior) corridors, stair halls and vestibule to offices, stair hall to passages, corridor to plumbing spaces, record room, janitor’s rooms, traffic room, switch rooms, operating rooms, equipment rooms, service and storage rooms, and machine rooms, each door to have:
Butts, type 2010%.
1 set locks, type 97 x knobs 210 x rose 330A.
1 door stop as limited.
D-9. Single communicating doors between rooms, each to have: Butts, type 2015%.
1	set locks, type 20 x knobs 210 x rose 330A x 2 turn knobs.
1	door stop as limited.
D-10. Single doors to or from closets, slop sinks, pipe shaft, equipment panel doors and access doors, each door to have:
Butts, type 2015%.
1 set latches, type 28 x knobs 210 x rose 330A.
Note.—If it is required to equip these doors with cylinder locks, 1 only dead lock type 114 x no turn knob may be used in addition to above.
1 door stop as limited.
D-ll. AU other single interior doors not otherwise specified, each door to have:
Butts, type 2015%.
1 set locks, type 97 x knobs 210 x rose 330A.
1 door stop as limited.
D-12. Pairs and single fire exit doors to fire escapes and fire towers, each door to have:
Butts, type 2010%.
1	fire exit bolt J5344L—each leaf. Sargent & Co. catalog, or equal. 1 surface door closer.
Note.—If fire tower doors are required to be kept open, holder arm with fusible link may be used.
12
SECTION E. DORMITORIES AND NURSES’ HOMES
E-l. The following requirements apply to dormitories and nurses’ homes and similar type buildings. See also section A.
E-2. Single exterior main entrance doors, each door to have: Butts, type 2010%.
1	set locks, type 800 except furnished with 2 cylinders and operated by handles type 420 from both sides of door.
1 surface door closer.
E-3. Other single exterior doors, each door to have :
Butts, tvpe 2010%.
1	set locks, type 800 except furnished with 2 cylinders and operated by handles, type 420 from both sides of door.
1 surface door closer.
E-4. Single or pairs doors vestibule, stair hall, toilet, toilet vestibule, shower and locker room, reception and recreation rooms, day rooms, and ' squad rooms, dining rooms and kitchens, each door to have :
Butts, type 2010%.
1 push plate, approximately 14 x 3% inches, glass or plastic.
1 door pull, type 452.
1 surface door closer.
1 door holder, type B1149—vestibule and stair hall doors only.
1 door stop as limited.
E-5. Single doors to or from storage, furnace, machine, equipment, kitchen, shops, and laundry rooms, each door to have :
Butts, type 2010% (type 2015%—storage rooms).
1 set locks, type 97 x knobs 210 x rose 330A.
1	surface door closer x holder arm—all doors except storage room doors.
1	door stop as limited.
E-6. Single doors to private or semiprivate rooms, each door to have :
Butts, type 2015%.
1	set locks, type 17A x knobs 210 x rose 330A x escutcheons 350A x turn knob.
(Note.—Where doors are communicating, lock type 20 may be used.)
1	door stop as limited.
E-7. Single doors to or from private and semiprivate toilets and baths, each door to have :
Butts, type 2015%.
1 set locks, type 17A x knobs 210 x rose 330A x escutcheons 350A x turn knob.
(Note.—Where doors are communicating, lock type 20 may be used.)
E-8. Single closet doors, slop sink, pipe shafts, each door to have : Butts, type 2015%.
1 set latches, type 28 x knobs 210 x rose 330A.
Note.—If it is required to equip these doors with cylinder locks, 1 only dead lock, type 114 x no turn knob may be used in addition to above.
1	door stop as limited.
13
E-9. Single double-acting doors, each door to have:
1	set floor hinges, type 3500 or 3510 as noted.
Note.—1 pair jamb D. A. spring hinges 2330A may be used in lieu of floor hinges where required.
1	dead lock, type 115.
2	push plates, approximately 14 x 3^ inches, glass or plastic.
E	-10. All other single doors not otherwise covered, each door to have:
Butts, type 2015^.
1	set locks, type 4A x knobs 210 x rose 330A x escutcheons 350A.
1 door stop as limited.
SECTION F. EDUCATION BUILDINGS AND
LABORATORIES
F-L The following requirements apply to educational buildings, laboratories, and similar type buildings. See also section A.
F-2. Pairs, main entrance doors, each pair to have:
Butts, type 2010^,
1	set fire exit bolts, J5391L (active leaf), J5344L (inactive leaf) Sargent & Co. catalog, or equal.
2	surface door closers.
F-3. Single main entrance doors, each door to have:
Butts, type 2010^.
1 set fire exit bolts, J5391L, Sargent & Co. catalog, or equal.
1 surface door closer.
F-4. Other single exterior doors, each door to have:
Butts, type 2010^.
1 set locks, type 97 x knobs 210 x rose 330A.
1 surface door closer.
F-5. Pairs exterior exit doors from corridors, auditoriums, assembly halls, etc., each pair to have:
Butts, type 2010^.
1 fire exit bolt, J5344L (each leaf) Sergent & Co. catalog, or equal.
F-6. Single or pairs vestibule and stair hall doors, each door to have: Butts, type 2010^.
1	pusn plate, approximately 14 x 8^ inches, glass or plastic.
1	door pull, type 452.
1	surface door closer.
1	door stop as limited.
F-7. Single or pair doors to or from toilet, toilet vestibules, locker or shower room, each door to have:
Butts, type 2010^.
1	pusn plate, approximately 14 x 3% inches glass or plastic.
1	door pull type 452.
1	surface door closer.
1	door stop as limited.
F-8. Single doors to or from private toilets, lavatories, etc., each door to have:
Butts, type 2015^.
1	set locks 17A x knobs 210 x rose 330A x escutcheon 350A x turn knob.
1	door stop as limited.
F-9. Single doors to or from corridor to class rooms, laboratories, offices, assembly and lecture halls, each door to have:
Butts, type 2015%.
1	door stop as limited.
1	set bit key school house locks x knobs 210 x rose 330A escutcheon 350A, case approximately 5% x 3% x % inches. Front approximately 7%. x 1% inches. Operation: Latch bolt by knobs from either side. Outside knob locked or released by key from either side. Inside knob operative at all times.
F-10. Single doors to or from storage, machine rooms, furnace rooms, equipment rooms, each door to have:
Butts, type 2010%, type 2015% for storage rooms.
1	set locks, type 4A x knobs 210 x rose 330A. x escutcheon 350A.
1	door stop as limited.
F-ll. Single doors from closets, slop sink, pipe shaft equipment panel and access doors, each door to have:
Butts, type 2015%.
1	set latches, type 28 x knobs 210 x rose 330A.
1	door stop as limited.
Note.—If it is required to equip these doors with locks, 1 dead lock 38A x escutcheons 350A may be added to the above.
F-12. Single double-acting doors, each door to have:
1	set floor hinges, type 3500 or 3510 size as required.
Note.—1 pair jamb double-acting hinges 2330A may be substituted in lieu of floor hinges.
1	dead lock, type 38A x escutcheons 350A.
2	push plates, approximately 14 x 3% inches, glass or plastic.
F-13. All other single doors not otherwise specified, each door to have:
Butts, type 2015%.
1 set locks type 4A x knobs 210 x rose 330A x escutcheons 350A.
1	door stop as limited.
SECTION G. HOSPITAL, DISPENSARY, AND INFIRMARY BUILDINGS
G-l. The following requirements apply to hospital, dispensary, infirmary, and similar type buildings. See also section A.
G-2. Door silencers.—Shall be omitted.
G-3. Hospital type surface door closer (for private rooms and wards) may be type as indicated elsewhere in this limitation, except that they may be arranged with a hold-open device.
G-4. Hospital arm door pull must be cast iron, base approximately 3 x 1% inches, projection 3% inches.
G-5. Pairs, main entrance doors, each pair to have:
15
Butts, type 2010%.
Note.—If single-acting floor hinges are required in Heu of butts and door closers, 2 floor hinges, type 3520A size as indicated may be used. Butts and door closers must be omitted.
1 dead lock, type 115.
2 flush bolts, type 1044B.
2 door pulls, type 452.
2 push plates, type 461, approximate size 14 x 3% inches, glass or plastic.
2 surface door closers.
2 overhead surface door holders as limited.
G-6. Single entrance doors, each door to have:
Butts, type 2010%.
Note.—If single-acting floor hinge is required in lieu of butts and door closer, floor hinge, type 3520A, size as indicated in proper table may be used. Butts and door closers must be omitted.
1 dead lock, type 115.
1 door pull, type 452.
1 push plate, type 461, approximate size 14 x 3% inches, glass or plastic.
1 surface door closer.
1 overhead surface door holder as limited.
G-7. Other exterior doors, each to have:
Butts, type 2010%.
1	set locks type 97 x knobs 210 .x roses 330A.
1	surface door closer with holder arm.
G-8. Single or pairs of doors to or from vestibule, reception, recreation rooms, stair hall, each door to have:
Butts, type 2010%.
1	pusn. plate, size approximately 14 x 3% inches, glass or plastic.
1	door pull, type 452.
1	surface door closer with holder arm (door closer on vestibule and stair hall doors only).
1	door stop as limited.
G-9. Single or pairs of doors to or from public toilets, toilet vestibules, locker and showers,kitchens, pantries, serving rooms and serving kitchens, each door to have:
Butts, type 2010%.
1	push plate, size approximately 14 x 3% inches, glass or plastic.
1	door pull, type 452.
1	dead lock, type 114 (no turn knob).
1	surface door closer.
1	door stop as limited.
G-10. Single doors to or from storage, machine, furnace, and equipment rooms, laundries, offices, drying rooms and incinerator rooms, each door to have:
Butts, type 2010%.
1	set locks, type 97 x knobs 210 x roses 330A.
1	surface door closer with holder arm (closer on storage room doors must be omitted).
1	door stop as limited.
492930°—42------------3
16
G-ll. Single doors to or from examination, therapy, X-ray, diagnostic, operating rooms and laboratories, each door to have:
Butts, type 2010% (for lead-lined doors type A2080 may be used).
1	dead lock, type 115.
1	push plate, size approximately 14 x 3% inches, glass or plastic.
1	hospital arm door pull as noted.
1	surface door closer with holder arm.
1	door stop as limited.
G—12. Single doors to or from nurseries, private rooms, wards, and solarium, each door to have:
Butts, type 2010%.
1	dead lock, type 114.
1	hospital arm door pull as limited.
1	push plate, size approximately 14 x 3% inches, glass or plastic.
1	surface door closer.
1 door stop as limited.
G-13. Single communicating doors between rooms, each door to have:
Butts, type 2015%.
1 set locks, type 20 x knobs 210 x roses 330A x 2 turn knobs.
1 door stop as limited.
G-14. Single doors to or from private toilets, each door to have: Butts, type 2015%.
1 set latches, type 28 x knobs 210 x roses 330A.
1	door stop as limited.
G-15. Single doors from closets, slop sinks, pipe shafts, equipment panels, each door to have:
Butts, type 2015%.
1 set latches, type 28 x knobs 210 x roses 330A.
Note.—If it is required to have these openings equipped with cylinder locks—1 dead lock, type 114, no turn knob may be added to the above. 1 door stop as limited.
G-16. Single double-acting doors, each to have: -
1	set of floor hinges, type 3500 or 3510 size as required.
Note.—1 pair jamb double-acting hinges 2330A may be substituted in lieu of floor hinges.
1	dead lock, type 115.
2	push plates, size approximately 14 x 3% inches, glass or plastic. G-17. Single doors, not otherwise specified (interior doors), each door to have:
Butts, type 2015%.	♦
1	set locks, type 97 x knobs 210 x roses 3330A.
1 door stop as limited.
G-18. Permanent psychiatric hospitals or psychiatric units in regular hospitals:
Note.—Refer to the foregoing limitations prepared for regular hospital and infirmary buildings, and the following limitations may be used. Butts.—AU butts in psychiatric area may be type 2061.
Single doors to or from private rooms or wards, each door to have—Butts, type 2061.
17
1 set locks, type A-40 x knobs 210 x roses 330A x escutcheon 350A outside, and cast flush cup approximately 3 inches in diameter with drop handle inside.
All door stops must be omitted in psychiatric unit and surface overhead door holder as noted may be substituted.
Where required, lock, type 7 or type 38A may be used in lieu of cylinder locks, types 97, 114, and 115.
SECTION H. WATERWORKS AND SEWAGE DISPOSAL PLANT BUILDINGS
H-l. The following requirements apply to waterworks, sewage disposal plants, and similar type buildings. See also section A, except for materials, and finish which may be as below.
H-2. Material and -finish: The following items, and all items covered under section A except door closers, when furnished for section H buildings, may be of wrought or cast brass so as to conform fully with the applicable Federal specifications.
Finish shall be US4 throughout. Subject to appeal under Copper Order M-9-c. Door closers shall be as required under section A.
H—3. Single exterior doors, each door to have:
Butts, type 2001%.
1 set locks 97 x knobs 210 x rose 330A.
H-4. Single doors to or from vestibule, corridor, and stair, each door to have:
Butts, type 2001%.
1	set latches, type 28 x knobs 210 x roses 320A.
1	door stop as limited.
H-5. Single doors to or from toilets, toilet vestibule, or locker rooms, each door to have:
Butts type 2001%.
1	door pull 452.
1 push plate, type 461, size 14 x 3% inches, glass or plastic.
1 surface door closer.
1 door stop as limited.
H-6. Single doors to or from private toilets, each door to have: Butts, type 2005%.
1 set locks 17A x knobs 210 x rose 330A x escutcheon 350A x turn knob.
1 door stop as limited.
H-7. Single door to or from closets, slop sinks, pipe shafts, each door to have:
Butts, type 2005%.
1	set latches, type 28 x knobs 210 x rose 330A.
H-8. All other interior doors not otherwise mentioned, each to have:
Butts, type 2005%.
1	set latches, type 28 x knobs 210 x rose 330A.
1	door stop as limited.
PART II.—RESIDENTIAL HOUSING
(Any amendment to the War Housing Critical List shall take precedent over this part of the manual)
SECTION A.	GENERAL
A-l. Type numbers.—Hardware items, unless otherwise described herein, are designated by type number selected from the applicable Federal specifications listed below, except as modified herein.
FF-H-106, hardware, builders’; locks and lock-trim.
FF—H-lll, hardware, builders’; shelf, and miscellaneous. FF-H-116b, hardware, builders’; hinges (nontemplate). FF-H-121a,_ hardware, builders’; door closers.
FF-P-lOla, padlocks.
A-2. Finishes permitted for iron and steel.—The finishes for iron and steel hardware covered by this schedule shall be limited to the following:
(1)	For all items other than door closers and butts—US18A, except where finish USP or japan finishes (US1B or US1D), or unfinished work is specified.
(2)	For butts—USP, except where finish US18A or japan finishes (US1B or US1D), or unfinished work is specified. Butts finished US18A may be unsanded.
(3)	For door closers, black paint or lacquer finish, except where finish USP is specified.
A-3. Materials.—Where Federal specification or other type numbers indicate brass or bronze material, such items shall be furnished in wrought steel, cast iron, or malleable iron. Brass may be used for essential interior parts, cylinder assemblies, and keys of cylinder locks only. Cylinder padlocks may have brass mechanism. Case and shackle shall be steel, cast iron, malleable iron, or die cast. Ferrous parts of padlocks may be zinc coated.
A-4. Where the use of brass is permitted, such brass mav be finished US3 or US4.
A-5. Keys.—Bit key locks shall have only one key for each lock. Locks and latches having cylinders, and padlocks, shall have only two keys for each lock. Only three master keys may be furnished with each group of locks when such locks are required to be furnished master keyed.
A-6. Strikes shall be flat type without boxes.
A-7. Door knobs shall be of wrought steel, glass, pottery, or plastic nor more than 2 inches in diameter. Knobs for mortise or tubular locks shall have bracket-type bearings and either threaded or triplex steel spindle.
(18)
19
A-8. Die castings shall meet all requirements on die castings in the effective issue of emergency alternate Federal Specification EFFH106.
A-9. Exterior doors 6 ft. or more in height may have three butts, size as permitted.
SECTION B.	DOORS
B-l. Entrance doors.—(a) Common entrance to multifamily dwellings.
1^ pair butts, type 2014^P. Primed: Size 3% x 3^ inches for 1%-inch door; size 4 inches for 1%-inch door.
Mortise-lock set, type 88: Type 88, 5 to 6 x 3% x % inches japanned iron case. Backset 2% inches. Solid front 8 x 1^4 inches.
Latch bolt minimum 1 x % inch; minimum throw inch. Dead bolt, minimum 1% x % inches, minimum throw % inch. Lock shall have 1 bronze cylinder, with or without removable and interchangeable core feature, with five or more pin tumblers giving practically unlimited changes. Ferrous front and bolts and wrought steel strike. Two brass keys.
Knobs: Type 210-B, except steel on exterior; glass, porcelain, or plastic on interior; wrought steel shank on glass knobs. Escutcheons. Type 300 outside x 302 inside; wrought steel or cast iron.
Option: Type 150, tubular or type 161, cylindrical, except steel or cast iron. Solid or two-piece front, ferrous metal for bolt, steel front, and strike. Type 154, tubular except steel or cast iron. Solid or two-piece front, brass 5-pin tumbler cylinder, 2 brass cylinder keys.
Knobs: 210-B except steel on exterior; glass, porcelain, or plastic on interior; wrought steel shank on glass knobs.
Escutcheons: Rose 1% x 2 inches or 2-mch diameter steel or cast iron on exterior; steel, cast-iron, or plastic on interior.
B-2. Interior entrance doors public hall to units in multifamily dwellings:
Pair butts type 2014J4P. Primed: Size 3% x 3^ inches for 1%-inch door; size 4 inches for 1%-inch door.
Mortise-latch set, type 28, except japanned iron case 1% x 3% x %6 inches; front wrought steel 314 x 1", compression spring, iron hub, ferrous bolt, steel strike. Latch bolt % x %6 x %-inch throw.
Knobs: Type 210-B, glass, porcelain, or plastic; wrought shank on glass knobs.
Escutcheons: Pendant type, wrought steel—cast iron or plastic, approximately 7 x 1% inches.
Option: Type 150, tubular or type 161, cylindrical, except steel or cast iron. Solid or 2-piece front, ferrous metal for bolt, steel front, and strike.
Knobs: Type 210-B, except steel on exterior; glass, porcelain, or plastic on interior; wrought steel shank on glass knobs.
Escutcheons: Rose 1^4 x 2 inches, or 2-inch diameter steel or cast iron on exterior; steel, cast-iron, or plastic on interior.
20
Rim night latch: 2% x 3% inches cast-iron case, ferrous bolt, brass 5-pin tumbler cylinder, 2 brass cylinder keys.
Option: Type 154 tubular, except steel or cast iron.
Solid or 2-piece front; brass 5-pin tumbler cylinder, 2 brass cylinder keys.
Wood door stop: 2%-inch projection, rubber tip, unfinished.
Letter box (only for multifamily dwellings) : Group letter boxes in accordance with United States Postal Regulations, ferrous metal only.
B-3. Entrance door to single family units.—
1% Pair butts type 2014%?. Primed: Size 3% x 3% inches for 1%-inch door; size 4 inches for 1%-inch door.
Mortise-latch set, type 28, except japanned iron case 1% x 3% x %6 inches front wrought steel 3% x 1 inch, compression spring, iron hub, iron bolt, steel front and strike. Latch bolt % x 7/16 x % inch throw.
Knobs: Type 210-B except steel on exterior, glass, porcelain, or plastic, on interior; glass knob with wrought steel shank.
Escutcheon: Pendant type approximately 7 x 1% inches, wrought steel, cast iron, or plastic.
Option: Type 150, tubular or type 161, cylindrical, except steel or cast iron. Solid or 2-piece front, ferrous metal for bolt, steel front, and strike.
Knobs: 210-B glass, porcelain or plastic; glass knob with wrought steel shank.
Escutcheon: Rose 1%. x 2 inches or 2-inch diameter, steel, cast iron, or plastic.
Rim night latch: 2% x 3% inches cast-iron case, ferrous bolt, brass 5-pin tumbler cylinder, 2 brass cylinder keys.
Option: Type 154 tubular, except steel or cast iron.
Solid or 2-piece front; brass 5-pin tumbler cylinder, 2 brass cylinder keys.
Wood door stop: 2%-inch projection, rubber tip, unfinished, B-4. Rear door.—
1% Pair butts, type 2014%P. Primed: Size 3% inches for 1%-inch door; size 4 inches for 1%-inch door.
Mortise-latch set, type 28, except japanned iron case 1% x 3% x %6 inches; front wrought steel 3% x 1 inch compression spring, iron hub, ferrous bolt, steel strike. Latch bolt % x %6 x % inch throw.
Knobs: Type 210-B, except steel on exterior; glass, porcelain, or plastic on interior; wrought steel shank on glass knobs.
Escutcheon: Pendant type, wrought steel or cast iron, approximately 7 x 1% inches.
Option: Type 150, tubular or type 161, cylindrical, except steel or cast iron. Solid or 2-piece front, ferrous metal for bolt, steel front and strike.
Knobs: Type 210-B, except steel on exterior; glass, porcelain, or plastic on interior; wrought steel shank on glass knobs.
Escutcheon: Rose 1% x 2 inches or 2 inch diameter, steel or cast iron on exterior; steel, cast iron, or plastic on interior.
21
Mortise bolt, type 153A steel or cast-iron bolt and strike; wrought steel or cast-iron turnpiece and plate.
Rin) night latch: 2% x 3% inch cast-iron case, ferrous bolt, brass 5-pin tumbler cylinder, 2 brass cy finder keys.
Option: Type 154 tubular, except steel or cast iron. Solid or 2-piece front; brass 5-pin tumbler cylinder, 2 brass cylinder keys.
Wood door stop; 2%-inch projection, rubber tip, unfinished.
B-5. Bathroom door.—	t
Pair butts type 2014%P. Primed: Size 3% inches for 1%-inch door; size 4 inches for 1%-inch door.
Mortise latch set type 28, except japanned iron case 1% x 3% x iVinch, front wrought steel 3% x 1 inch, compression spring, iron hub iron bolt, steel front and strike. Latch bolt % x x %-inch throw.
Knobs: Type 210-B, glass, porcelain, or plastic; glass knob with wrought steel shank.
Escutcheon: Pendant type approximately 7 x 1%-inch wrought steel, cast iron or plastic; stop on inside to lock against outside; emergency entrance from outside.
Option: Type 150, tubular or type 161, cylindrical, except steel or cast iron. Solid or 2-piece front, steel bolt, front and strike.
Knobs: Type 210-B glass with wrought steel shank, porcelain, or plastic.
Escutcheon: Rose 1% x 2 inches or 2-inch diameter, steel, cast iron, or plastic; stop on inside to lock against outside; emergency entrance from outside. Stops may be in knob or tubular types.
B-6. Interior doors, closet doors.—
Pair butts, type 2014%P. Prime: Size 3% inches for 1%-inch door; size 4 inches for 1%-inch door.
Mortise latch set type 28, except japanned iron case 1% x 3% x ^-inch; front wrought steel 3% x 1-inch compression spring, iron hub, iron bolt, steel strike.
Knobs: Type 210-B glass with wrought steel shank, porcelain, or plastic. Standard closet spindle.
Escutcheon. Pendant type, wrought steel, cast iron, or plastic; approximately 7 x 1%-inch.
Option: Type 150, tubular or type 161, cylindrical, except steel or cast iron. Solid or 2-piece front, iron or steel bolt, steel front and strike.
Knobs: Type 210-B glass, with wrought steel shank, porcelain, or plastic; turn knob head on spindle for closet interiors.
Escutcheon: Rose 1% x 2 inches or 2-inch diameter, steel, cast iron, or plastic.
B--7. Double acting doors.—
Set of steel floor hinges, double-acting commercial spring type with wrought steel side plates having prime coat.
Push plates, beveled glass or plastic, size approximately 3 x 12 inches.
22
B-8. Screen doors.—
Spring hinges, shall be cast iron or wrought steel japanned, surface type, size 3-inch fixed tension coiled spring.
Catches shall be either rim type or tubular mortise type wrought steel or cast iron.
Opinion: Pair Butts 3x3 inches—Coiled Spring % inch—Hook and Eye 3 inches—Ferrous Metal.
SECTION C.	MISCELLANEOUS
C-L Clothes closets.—No hardware on interior.
C-2. Cabinets.—
Hinges for lipped doors, steel, prime coat, surface type, or semisurface type exposed or semiconcealed; for flush doors, concealed pivots may be used. Knobs or pulls shall be glass, plastic, or hardwood, unfinished.
Catch, friction catch, or push-button catch.	>
Note.—Flush doors requiring no pulls or knobs preferred.
SECTION D.	WINDOWS
D-l. Double-hung sash.—
Spiral and spring balances, ferrous metal (only one balance per sash).
Sash lock, cast iron or wrought steel, approximate size 2^ x % inches.
D-2. Casements.—Opening in.
Butts 3x3 inches, type 2014^ P.
Surface bolts, type 1060-A, size 6 inches (for pairs of casements only).
1 only casement fastener, lever handle projecting 1^ inches, approximately 1% x 1TV inches.
D-3. Casements.—Opening out.
Butts 3x3 inches, type 2OI414P.
One pair half surface steel extension hinges prime coat, for single sash only where sash cannot be reached from ground, roof, or similar point of access.
Surface bolts type 1060A, size 6 inches (for pairs of casements only).
One only casement fastener lever handle projecting inches, approximately 1% x 1 inches.
One only casement adjuster, type 1000, except of ferrous metal (one to each sash) or one 8-inch ferrous metal hook and eye.
Option, steel pivot top and bottom fixtures—pivot consists of sill plate, sash plate, arm and sliding shoe.
D-4. Cellar windows.—Shall have complete set, wrought steel, japanned, including 1 pair hinges, 1% x 2% inches japanned steel, fast pin 0.06-inch thick, catch B 1137A hook and eye 1601C except japanned, and eye for holding open.
23
D-5. Window screens.—Transoms.
Full length, hangers, type 1825 to No. 1825-B, to suit detail; hook-and-eye type 1601-C, size inches (unfinished).
Sliding screens—2 steel springs, one lift, japanned, 1223A.
D-6. Storm sash.—1 pair hangers—2 10-inch adjusters ferrous metal.
SECTION E.	GARAGE HARDWARE
Hinge type, type No. 2209,12-inch with steel pin, 3 to the door.
Thumb latch, type 1189A.
Bolt, type 1022B, 6-inch.
Cane, 12-inch wrought steel.
Padlock eyes, No. 1430.
SECTION F.	MAINTENANCE AND MANAGEMENT BUILDING
F-l. Exterior entrance doors to public space to have hardware as specified for entrance doors to single units:
Stationary leaf of double doors to have chain bolt, type 1025A, 6 inches at top; and foot bolt, type 1047A, 6 inches at bottom.
Other exterior door to have hardware as specified for entrance doors, to single units.
F-2. Doors to manager’s office, doors to superintendent’s office, doors to other rooms indicated as requiring locks with keys, such as storerooms, shops, etc., to have hardware as specified for interior entrance doors to units in multifamily dwellings.
F-3. Doors to private toilets to have hardware as specified for bathroom doors in dwelling units substituting lock, type 17A, E, K, with wrought-steel front and strike.
F-4. Doors to public toilets, other interior doors, to have hardware as specified for interior doors in dwelling units.
F-5. Cabinets under counter in public space to have hardware as specified for cabinets. Doors requiring locks to have type 701B cupboard lock with wrought-steel case, bolt, strike, and cylinder.
F-6. Windows to have hardware as specified under windows and casements in dwelling units.
SECTION G.	GENERAL
G-l. Padlochs.—Padlocks for bulkheads, garages', and doors to cellar spaces shall be 1% inches in size, disk tumbler, or pin-tumbler construction with ferrous case.
G-2. Self-releasing fire-exit devices, where required by applicable code or regulation, ferrous metal, no metallic coating.
G-3. Automatic fire-door fixtures, where required by applicable code or regulation, ferrous metal, no metallic coating.
G-4. Door closer.—
Type 3001, ferrous metal with hold-open feature size is required according to manufacturers schedule of requirements for various size doors.
492930°—42-----------4
24
Door closer bracket (ferrous metal) for doors opening out, or other conditions where bracket is essential.
Closers allowed only for doors permitted under item 250 and on entrance doors to public toilet rooms having more than two urinals and/or water closets.
G—5. Wood venetidl-blind hardware. Not more than 15-oz. of metal per blind.
G-6. Shade fixtures, ferrous metal, no metallic coating.
G-7. Brackets for wood hand rails, ferrous metal, no metallic coating.
SECTION H.	DORMITORIES—TEMPORARY BUILDINGS
H-l. Exterior entrance doors.—
1% pairs butts, 2014% P, primed, size 4x4 inches.
Mortise lock, type 105, with 1 cylinder only. Stop work controlled through cylinder by custodian or management key. Type 105, 5 to 6 x 3% x % inches japanned iron case. Solid or 2 piece front. Cylinder may be with or without removable core feature with 5 or more pin tumblers and 2 brass keys. Ferrous front bolts and strike.
Knobs, type 210-B, except steel on exterior; glass, porcelain, or plastic on interior. Wrought steel shank on glass knobs.
Eschutcheons, type 300, size 10 x 2^4 inches wrought steel or cast iron outside; type 300, size 7 x 2% inches wrought steel, cast iron, or plastic inside.
Option, lock, type 165, cylindrical, except that stop work is to be controlled only through cylinder by custodian or management key.
Knobs, type 210-B, except steel on exterior, glass, porcelain, plastic; on interior. Wrought steel shank on glass knobs.
Escutcheons, rose of standard diameter required for proper application, wrought steel or cast iron on exterior, wrought steel, cast iron, or plastic on interior.
Pairs of doors, stationary leaf, 1 surface bolt, 1060A, % inch half roud, 12 inches long for top ; 1 surface bolt, 1060A, % inch half round, 9 inches long for bottom.
H—2. Exterior exit doors.—
1% pairs butts, 2014%P, primed, size 4x4 inches. Self-releasing fire-exit devices, ferrous metal, no metallic coating.
H-3. Vestibule doors.—Doors, corridors to stair halls. Doors in firewall connecting corridors. Doors, corridors to public toilets and shower rooms.
Pair butts, 2014%P, primed (doors over 7 feet to have 3 butts) ; size 3%.x 3% for 1%-inch door; size 4 inches for 1^4-inch door.
Push plate, 14 x 3%, glass or plastic.
Door pull, 6% inches, ferrous or plastic, without backplate.
H-4. Doors, corridors to dwelling room. Doors, corridor to house supervisor apartment. Doors to offices. Doors to other rooms indicated as requiring locks with keys, such as domestic rooms, storage rooms, storerooms, mail rooms, coatrooms, diet kitchens, shops,'to
25
have hardware as specified for interior entrance. Dutch doors to have surface bolt, 1060A, %-inch half round 4 inches long.
H-5. Closets in individual dwelling rooms.—
Pair butts, 2014i^P, primed, size 3^ x 3y2 inches for 1%-inch doors.
1^ pairs, half surface hinges, primed, size 3 inches with fast-pin for %-inch plywood doors; rim, night latch 2% x 3% inches, cast-iron case, ferrous bolt and strike. Cylinder may be with or without removable core feature with 5 or more pin tumblers and 2 brass keys. Omit latch hold-back feature.
Option, type 154, tubular, except steel, or cast iron. Solid or 2-piece front. Cylinder may be with or without removable core feature with 5 or more pin tumblers and 2 brass keys. Ferrous front, bolt, and strike. Omit latch hold-back feature. Knob, nonmetallic with bolt through door.
Note.—Where thin doors require other than manufacturer’s standard cylinder ring difference is to be adjusted with wood.
H-6. Doors to private bathrooms off shower rooms or corridors. Doors to private toilet rooms off vestibule, corridors, or offices to have hardware as specified for bathroom doors in dwelling units substituting lock, type 17A-EK, with wrought-steel front and strike.
H-7. Stall doors in toilet.
Pair spring hinges, cast-iron or wrought-steel japanned, surface type, size 3 inches, with fixed tension spring.
Mortise bolt, type 1053A, steel or cast-iron case, bolt, and strike; wrought-steel or cast-iron turn piece and plate.
Pulls, size 4 inches, wrought steel or cast iron.
H-8. Janitors, cldsets or other closets in corridors, offices, etc. (except closets in dwelling rooms) to have hardware as specified for closet doors in dwelling units.
Where doors are required to be locked; rim, night latch, 2% x 3% inches, cast-iron case, ferrous bolt and strike. Cylinder may be with or without removable core feature with 5 or more pin tumblers and 2 brass keys.
Option, type 154, tubular, except steel or cast iron, solid or 2-piece front. Cylinder may be with or without removable, core feature with 5 or more pin tumblers and 2 brass keys. Ferrous front bolt and strike.
H-9. Double-acting doors to have hardware as specified for doubleacting doors in dwellings. Doors requiring lock to have type 153 tubular dead lock steel or cast iron. Solid or 2-piece front. Cylinder may be with or without removable core feature with 5 or more pin tumblers and 2 brass keys. Front, bolt and strike to be ferrous metal, type 1060A, wrought steel bolts, %-inch half round, 12 inches long at top and 9 inches long at bottom for pairs of doors.
H-10. Panel boards.—Key cabinets, pair wrought-steel butts with fast pin, size 2% inches, type 701B, cupboard lock with wrought steel case bolt and strike, length of cylinder governed by thickness of door.
26
. H-ll. Batten doors.—Pair wrought steel T hinges 6 inches; rim, night latch, 2% x 3% inches, cast-iron case, ferrous bolt and strike. Cylinder may be with or without removable core feature with 5 or more pin tumblers and 2 brass keys.
H-12. AU other doors not otherwise covered to have hardware as specified for interior doors in dwellings. Doors requiring lock to have type 4A lock, size 3% to 3% x 3^4 to 3^ x % inches, japanned iron case, front 5^4 x 1 inch. Lock shall have 1 tumbler and 1 steel key. Front, bolts, and strike to be ferrous metals.
H-13. Double-hung windows to have hardware as specified under “Dwellings.”
H-14. Casements to have hardware as specified under “Dwellings.”
H-15. Horizontal sliding sash, ferrous metal fastener with 2 strikes to permit ventilation.
H-16. Gates in office counters. Pair spring hinges, wrought steel or cast iron, japanned, surface type, size 3 inches, with fixed tension spring.
H-17. Cabinets. Hardware as specified under cabinets in dwelling units. Doors requiring locks to have type 701B cupboard lock with wrought steel case, bolt, strike and cylinder.
PART III.—CANTONMENTS AND SIMILAR TYPE BUILDINGS
SECTION A. GENERAL
A-l. Type numbers.—Hardware items, unless otherwise described herein, are designated by type number selected from the applicable Federal specifications listed below; except as modified herein:
FF-H-106, hardware, builders’; locks and lock trim.
FF-H-111, hardware, builders’; shelf, and miscellaneous. FF-H-116b, hardware, builders’; hinges (nontemplate).
FF-H-121a, hardware, builders’; door closers.
FF-P-lOla, padlocks.
A-2. Materials.—Where Federal specification or other type numbers indicate or specify brass or bronze material, such items must be furnished in wrought steel, ¿ast iron, or malleable iron. Brass may be used for essential interior parts, cylinder assemblies and keys of cylinder locks only. Cylinder padlocks may have brass or zinc die cast mechanism. Case and shackle may be steel, cast iron, or malleable iron. Ferrous parts of padlocks may be zinc coated.
,	A-3. Finish.—All ferrous hardware shall be finished USIB, except
exterior butts, which shall have finish USP, and except iron and steel faces for mortise locks, which shall have finish US18A. When the use of brass is permitted such brass shall be finished US3 or US4.
A-4. Keys.—Bit key locks may have one only key for each lock. Locks and latches having cylinders and padlocks may have two only keys for each lock. Only three master keys may be furnished with each group of locks when such locks are required to be furnished master-keyed.
A-5. Lock trim for mortise locks may have pressed steel knobs (not larger than 2*4 inches in diameter) and elongated escutcheons (not larger than 7 x 2^ inches). Rim locks shall have pressed steel knobs (not larger than 214 inches in diameter) with pressed steel rose and key plate one side. Pottery, glass, or plastic knobs may be substituted.
A-6. Surface door closers, may be types 3001, 3003, 3004, or 3006. Where butts are less than 6 inches from intersecting wall, or partition, the closers shall have soffit brackets. Size of closers shall be as indicated in table on page 4 of Specification FF-H-121a. Where surface door closers withhold-open arms are permitted in these limitations, a door holder type B-1149 may be used in lieu of hold-open feature where practicable. Where surface door closers with hold-open feature are required on underwriters’ label fire doors, a closer, bearing underwriters’ label with automatic fusible link release mechanism may be furnished. Subject to steel conservation order M-126 and amendments thereto.
(27)
28
A-7. Coat and hat hooks shall be omitted.
A-8. Butts and hinges.—Doors 7 feet or less in height may have not more than 2 butts or hinges as required, and for greater height one additional butt or hinge for each additional 2% feet or fraction thereof. Except that doors 6 feet or more in height, and all doors exceeding 3 feet 4 inches in width may have 3 butts. Size of butt must be as indicated for various size doors in table I below:
Table I.—Rule for size of butt hinges
Thickness in inches	Width of doors in inches	Height of butt hinges in inches '
% to 1% cabinet doors					2%.
% to 1% screen or combination doors __		3.
1% doors		 	 				3%.
	CTo 36		4.
134 doors 		 		I Over 36 to 40	4%.
	[Over 40	 		5.
2, 2J4, and 2% doors	,			5, extra heavy.
1%, and 1% transoms and casements. _		3.
2, 2%, and 2% transoms and casements _ _	—	3%.
Note.—Cast-iron butts may be substituted for the butts listed, as follows:
Wrought butt listed :	Comparable cast butt
2014%P—2-----------------------------------160BT primed for paint, or 04.
2015________T___________________________160.
2015%----------------1----------,----.-----160BT unpolished.
2029B______________________________________162.
2031A______________________________________G160BT.
2010_______________________________________161%.
2010%P_________________.—_L._____________ 161%BT primed for paint.
2061_______________________________________152.
2080%P_____________________________________169.
Note.—In the above comparative list, numbers 160, G160, 152, 169, 161%, and 040 are from the catalog of P. & F. Corbin. Butts of other manufacture having the same general design of approximately the same weight may be used.
A-9. Light strap and T hinges shall be of wrought steel with steel pin, and shall be of the following dimensions in inches:
	Strape	Tee
Length closed size		6	6
Width of strap at joint 				1^0	1%6
Length of joint		 _		3%
Width of pad __ ____		%
Minimum thickness of metal					0. 080	0. 080
A-10. Counter gates, single acting, each to have— 1 pair hinges, type 2331A, size as required.
A-ll. Counter gate, double acting, each to have— 1 pair hinges, type 2330A, size as required.
1 secret gate latch A1187, except double-acting.
29
SECTION B
B-l. Double bung windows.—
Barrel bolts—1019B—3 inches, no strikes (no more than 4 bolts to a window), or steel window control springs.
B-2. Doors —
■Exterior doors.—Butts 3^ x 3^ inches, type SOll^P-
Locks, type 4, modified as follows: Single compression spring, steel front, iron bolts, approximate size case 3% x 3% x inches, front 5^ x % inches. Doors required to have cylinder locks may have night latch type 136 in addition to modified type 4.
Top and bottom bolts: 6 inches, type 1060A, inactive leaf of double doors only.
Interior doors.—3% x 3% inches, type 2015.
Locks, type 59, malleable iron or steel key. Doors required to have cylinder locks, except projection booths, may have in addition to type 59 lock, 1 type 136 night latch.
Top and bottom bolts: 6 inches, type 1060A—inactive leaf of double doors only.
Locks, type 97 : Projection booths, lock (detention room doors of wards), doors opening in, type 114 without turn knob; doors opening out, type 116 without turn knob.
Pull (detention room doors of wards, on room side only), No. 8007, Lockwood Hardware Mfg. Co., catalog No. 20, or equal, with recessed head screws.
Pull (detention room doors of wards on exterior side only), type 1274C.
B-3. Interior double doors in enclosed covered walks.—
Butts, 3^ x 3^ inches, type 2015.
Door pull, type 1274C.
Push plate, type 462, except wrought steel.
Door closer, size II.
Hook and eye, type 1601C, except Japanned, size 4.
B-4. Screen doors.—
Butts, 3x3 inches, type 2031. (Surface hinge 3 x 2% inches similar to Stanley Works No. 1751 may be furnished in lieu of butts.)
Door pulls, type 1269B.
Coil springs, steel—not less than 1%2'inch diameter, with attachments.
Closer (hospitals including covered walls and administration buildings), type 3015 with steel tube (in lieu of coil spring).
B-5. Hinged shed doors.—
T hinges, type 2209, 12-inch with steel pin, with stove bolts and washers for strap leaf and lag screws for jamb leaf.
Bar holders (1 each leafL Richards-Wilcox No. 73-4, catalog 60, or equal.
Cane bolt, 18-inch (1 each leaf), type 1051A, except plain steel rod.
30
B-6. Hinged shop doors.—
T hinges, type 2209, 12-inch with steel pin, with stove bolts and washers tor strap leaf and lag screws for jamb leaf.
Chain bolt, 8-inch (for inactive leaf), type 1022B.
Cane bolt, 18-inch (for inactive leaf), type 1051A, except plain steel rod.
Square bolt, 10-inch (1 only), type 1059 (surface strike).
Thumb latch, type 1189A.
B-7. Exterior batten doors.—(Fire station).
T hinges, type 2209, 12-inch with steel pin, with stove bolts and washers for strap leaf and lag screws for jamb leaf.
Bar holders (1 each leaf), Richards-Wilcox No. 73-4, catalog 60, or equal.
Cane bolts, 18-inch (1 each leaf), type 1051A, except plain steel rod.
B-8. Boiler house—Exterior batten doors.—
Hinges, type 2140, 36-inch with carriage bolts for strap leaf.
Thumb latch, type 1189A.
Cane bolts, 18-mch (1 each leaf) type 1051 A, except plain steel rod.
Chain bolt, 8-inch-type 1022B.
Padlock eyes, type 1430.
Padlock, 1%-inch, type Id or lb with chain as normally used for Id.
B-9. Boiler, house—Exterior batten door.—
T hinges, type 2209, 12-inch with steel pin, with stove bolts and washers for strap leaf and lag screws for jamb leaf.
Thumb latch, type 1189A.
Cane bolts, 18-inch (1 each leaf) type 1051A, except plain steel rod.
Chain bolt, 8-inch, type 1022B.
Padlock eyes, type 1430.
Padlock, 1%-inch, type Id or lb with chain as normally used for Id.
B-10. Batten doors to toilet enclosures.—
T hinges, 6-inch, light T hinge as noted (par. A-9), except for half surface application.
Barrel bolt, type 1019B, 3-inch.
B-ll. Kitchen counter and batten doors.—
Strap hinges, 6-inch, light strap hinge as noted (par. A-9).
Barrel bolts, type 1019B, 5-inch (2 each door).
B-12. Batten doors over pharmacy cou/nter.—
T hinges, 6-inch, light T hinge as noted (par. A-9).
Barrel bolts, 5-inch, type 1019B.
B-13. Batten doors in gables.—
T hinges, 6-inch, light T hinge as noted (par. A-9).
Catches, type 1097A.	♦
Sash cord, by general contractor.
Pulleys (1-inch), type 71, Sargent’s catalog, or equal.
Cleats, type 112, except japanned, Sargent’s catalog, or equal.
31
B-14. Trap door.—
T hinges (6-inch), light T hinge as noted (par. A-9).
Drop handles, type 2233, Sargent’s catalog, or equal.
B-15. Roof scuttle in boilerhouse.—
Hinges, type 2240B.
Hooks and eyes, type 1601C, 4-inch, except japanned.
B-16. Ceiling scuttle doors (radio school building).—
T Hinges, 6-inch, light T hinge as noted (par. A-9).
Hook and eye, type 1601C, 4-inch, except japanned.
Door pull (1 each side), type 1274C.
B-17. Access doors in fire stop partitions (radio school building).—-T hinges, 6-inch, light T hinge as noted (par. A-9).
Door pull, type 1274C.
Hook and eye, 2-inch, type 1601C, except japanned.
B-18. Sliding doors.—Track, standard box or tubular design, with brackets, stops, etc., for complete installation. Two hangers per leaf. Brackets for track spaced approximately 24 inches o. c. Hangers wrought steel, malleable iron, or drop-forged steel. Hanger truck may be of cast iron. Rollers may be on ball or roller bearings.
Doors	Track (minimum)	Wheel diameter (minimum) (inches)
Up to 350 pounds	 350-600 pounds.	 600-900 pounds	 900-1, 200 pounds	 2,000 pounds and over		Box	Round 1% x 2 x 16 gage	1% 2^6 x 3% x 14 gage	2% 2% x 3^ x 13 gage 1	2H 2% x 3% x 10 gage 1	2}^ 2% X 4^6 X 9 gage		Box	Rd. 1%	1%6 3	2% 3	2% 3	2% 4
i 12-gage track 2Ms x 3J4 inches with brackets 18 inches on centers may be used for doors of 600 to 800 pounds, and with brackets 12 inches on centers for doors of 800 to 1,000 pounds.
Hasp, 6-inch, type 1420.
Padlock, 1% inch, type Id or type IB with chain as specified for Id.
Stay rollers,, type No. 55, Richards-Wilcox catalog, or equal.
B-19. Hinged sash.—
Butts, 3 x 3 inch, type 2029B.
Transom chains, 15-inch, type 1120B, except japanned (2 required). (Side hinged sash omit transom chains.)
Transom catch, type 1097A.
B-20. Hinged sash (boilerhouse).—
Butts, 3x3 inch, type 2029B.
Transom catch, type 1097A.
Hook and eye, 2-inch, type 1601C, except japanned (2 each sash).
B-21. Clerestory sash (mess halls) may have worm and gear operator for control of sash from floor. Operation may be by continuous hand chain or spiral rod and handle.
B-22. Clerestory and transom sash (boilerhouse).—
Butts, 3x3 inches, type 2029B.
Transom catch, type 1097A.
Pulleys, 1 inch, type 71, Sargent’s catalog, or equal.
Cleats, type 112, Sargent’s catalog, or equal.
32
B-23. Transom oner batten doors (boilerhouse).—-
1% pair butts, 3x3 inches, type 2029B.
2 hooks and eyes, 2 inches, type 1601C, except japanned.
B-24. Window screens.—
Screen hangers, type 1825, except japanned.
Hook and eye, inches, type 1601C, except japanned.
B-25. Hinged window guards (wood).—
pairs butts, 3x3 inches, type 2029P.
2 safety hasps, 4^ inches, type 1420.
2 padlocks, 1% inches, type Id or type lb with chain as normally used for Id.
B-26. Cabinets and cupboards, each door to have—
Butts, 2% x 2inches, type 2018 (1 pair).
Elbow catches, type 1079 (pairs of doors only).
Cupboard turns, type 1082C.
Drawer pulls, type 1296 (1 each drawer).
B-27. Poison cabinets in pharmacy, each door to have—
Butts, 2% x 2 inches, type 2018 last pin (1 pair).
Elbow catch, type 1079 (pairs of doors only).
Cupboard turns, type 1002C.
Lock, type 701A.
B-28. Display cases, each door to have—
Butts, 3x3 inches, type 2014^P.
Friction catch.
B-29. Pot hooks for cook's table.—%6 inch zinc-coated wrought steel bar hooks, type No. 205, Sargent’s catalog or equal.
B-30. Miscellaneous items where required must be furnished according to the following list:
Door buttons, type 1069,1% inches, except japanned.
Sash pivots, type 1114A.
Hitching rings at mangers, % inch diameter stock, ring diameter not larger than 1% inches, bolts not larger than 2^ inches.
Double acting hinges, type 2330A.
Drawer locks, type 655A.
B-31. Panic hardware.—
A.	Exit bolt (inactive leaf), type No. J5344L, Sargent catalog, or equal.
B.	Exit bolt (active leaf), type No. J5391L, Sargent catalog, or equal.
B-32. Hinged guard rail at fire ladder balcony.—
Butts, 3x3 inches, type 2029P.
Barrel bolt, type 1019B, 5 inch.
PART IV.—INDUSTRIAL TYPE BUILDINGS AND BUILDINGS FOR ARMY AND NAVY BASES
SECTION A. GENERAL
A-l. Type numbers.—Hardware items, unless otherwise described herein, are designated by type numbers selected from the applicable Federal specifications listed below, except as modified herein.
FF-H-106, hardware, builders’; locks and lock trim.
FF-H-111, hardware, builders’; shelf and miscellaneous.
FF-H-116b, hardware, builders’; hinges (nontemplate).
FF-H-121a, hardware, builders’; door closers.
FF-H-136, hardware and fittings, for lavatory partitions and enclosures.
FF-P-lOla, padlocks.
A-2. Finishes permitted for iron and steel.—The finishes for iron and steel hardware covered by this schedule shall be limited to the following:
(1)	For all items other than door closers and butts, US18A, except where finish USP or japan finishes (US1B or US1D), or unfinished work is specified.
(2)	For butts, USP, except where finish US18A or japan finishes (US1B or US1D), or unfinished work is specified. Butts finished US18A may be unsanded.
(3)	For door closers, black paint or lacquer finish, except where finish USP is specified.
A-3. Materials.—Where Federal specifications or other type numbers indicate or specify brass or bronze material, such items must be furnished in wrought steel, cast iron, or malleable iron. Brass may be used for essential interior parts, cylinder assemblies, and keys of ■ cylinder locks only. Cylinder padlocks may have brass or zinc decast mechanism. Case and shackle may be steel, cast iron, or malleable iron. Ferrous parts of padlocks may be zinc-coated.
A-4. Keys.—Bit key locks may have only one key for each lock. Locks and latches having cylinders and padlocks may have only two keys for each lock. Only three master keys may be furnished with each group of locks when such locks are required to be furnished master keyed.
A-5. Strikes shall be flat type without boxes.
A-6. Alternate lock trim.—Knobs, roses, and escutcheons required under this specification are of cast metal. Where wrought metal trim is desired, type numbers for knobs, roses, and escutcheons under requirements for the various doors should be changed as follows:
Knobs 210 change to 211B.
Roses 330A change to 330.
Escutcheons 350A change to 350.
(88)
34
For quarters of all classes, the type numbers for knobs, roses, and escutcheons may be changed as follows:
Knobs 210, for exterior doors, change to 210B.
Knobs 210, for interior doors, change to 211B, except of wrought steel, glass, pottery, or plastic not larger than 2^4 inches in diameter.
Roses 330A change to 330.
Escutcheons 350A change to 350.
A-7. For doors 1% inches thick, escutcheons of elongated or pendant design may be used for mortise- locks and latches in lieu of roses.
A-8. Alternate locks and latches for interior doors.—Cylindrical case locks and latches of “heavy duty’ Schlage type C with case D may be substituted for locks and latches specified herein for interior doors, provided that the cylindrical case locks and latches are designed and constructed so as to give same performance in operation and control as corresponding locks specified. Cylindrical case locks and latches must comply with Federal Specification FF-H-106.
A-9. Door stops shall be wood.
A-10. Surface door closers may be types 3001: 3003, 3004, or 3006. Where butts are less than 6 inches from intersecting wall or partition the closer may have a Soffit bracket. Size of closer shall be not larger than as indicated in table on page 4, of Specification FF-H-121a. Where surface door closers with hold-open arms are shown in the limitations, a door holder type B-1149 may be used in lieu of holdopen feature. Where surface door closers with hold-open features are required oh underwriters’ label fire doors a closer bearing underwriters’ label with automatic fusible link release mechanism may be furnished. Subject to Steel Conservation Order M126 and amendments thereto.
A-ll. Surface overhead door holders may be ferrous metal with encased automatic engagement, release action, and shock absorber, and may have adjustable sliding tension hold-open feature, sliding in a channel and engaging when the door is open at 90° to 95°, and with control knob in the end of the channel for disengaged position. Where a small door holder is desired type E1149 as covered by Federal Specification E-FF-H 111 may be used.
Note.—Where floor type door holders are required, type C-1149A may be used in lieu of the surface overhead type.
A-12. Coat and hat hooks shall be omitted.
A-13. Butts and hinges.—Doors 7 feet or less in height may have not more than 2 butts or hinges as required, and for greater height one additional butt or hinge for each additional 2^ feet or fraction thereof. Except that exterior doors 6 feet or more in height, and all doors exceeding 3 feet 4 inches in width may have 3 butts. Size of butt shall be as indicated for various size doors in table I below:
A-LS^- Industrial wood sash shall have ferrous hardware not exceeding 2^ pounds per vent.
35
Table I.—Rule for size of butt hinges
Thickness in inches	Width of doors in inches	Height of butt hinges in inches
% to 1% cabinet doors	 % to 1% screen or combination doors	 1% doors		 1% doors	 2, 2%, and 2J^ doors	r	 1% and 1% transoms and casements	 2, 2%, and 2H transoms and casements. _	iTo 36	 < Over 36 to 40	 [Over 40		2^. 3. 3^2. 4. 4y2. 5. 5, extra heavy. 3.
Cast iron butts may be substituted for the butts listed as follows:
Wrought butt listed :	Comparable cast butt
2014%P_____________________________________________160 BT primed for paint, or 040.
• 2015_______________________________________________160.
2015^_______________________________________-______160 BT, unpolished.
2029B______________________________________________162, unpolished.
2031A____________________________L_________________G160 BT.
2010____________________________________________—161 %.
2010%P_______________________________________________161^	BT, primed for	paint.
2061_______________________________________________152
2080y2P____________________________________________169.
Note.—In the above comparative list, numbers 160, G160, 152, 169, 162, 161%, and 040 are from the catalog of P & F Corbin. Butts of other manufacture having the same general design and of approximately the same weight may be used.
A-13a. Where spring hinges are required, proper sizes shall be taken from table under type 2330, FF-H-116b, except where sizes are limited.
A-13b. Checking floor hinges where required for single-acting type may be type 3520A. On double-acting doors, they may be type 3500 or 3510. Size shall be as indicated for size of door in Federal Specification FF-H-121a. On single-acting and double-acting doors overhead concealed closers may be substituted for checking floor hinges.
A-14. Counter gates, single-acting, each to have:
1	pair hinges, type 2331A size as required.
A-15. Counter gates, double-acting, each to have:
1	pair hinges, type 2330A size as required.
1	secret gate latch, type A1187, except double-acting.
A-16. Cabinets, single and pair doors.—
1 pair butts, type 20181/2.
1	only elbow catch, type 1079 (for pair doors only).
1	only knob pull, type A1283 (1 to each door).
1	only friction catch.
Note.—Where cabinets are required to be locked, 1 only lock, type 701A (1 to each single or pair door may be used).
1	drawer pull, type 1296, or bar type pull of glass or plastic. Where drawers are required to be locked, 1 only lock 655A (1 to each drawer) may be used.
36
A-17. Transoms, and 'bottom-hinged sash, each to have:
1	pair butts, type 2029B.
1	only transom catch, type 1097.
2	only transom chains, type 1120A.
Note.—Transom lifts type 1198G or type 1198K as required may be substituted for transom catch 1097 and chains 1120A. If transom lift is substituted, catch and chains must be omitted.
A-18. Pivoted sash, each to have:
1	set pivots, type 1115A.
1	only transom catch, type 1097.
A-19. D. H. Windows, each to have:
1	only sash lock type 1139 (except tumbled finish).
1	only sash lift type 1201A (except tumbled finish) on sash over 18 inches, 2 lifts may be furnished.
Sash balances may be of single coiled-spring (clock Spring) type with suspension tape, or twin coiled flat type with suspension cables, or single helical spring “vertical” type with tubular housing. Springs may be high-carbon steel uniformly tempered. Suspension tapes and cables may be coated with zinc. The single coiled-spring type may have pressed steel or cast iron case and front for mounting in mortise in window frame. The twin coiled-spring type shall have a pressed steel case for mounting flatwise in cut-out in window frame. For each pair of sash, two pairs of balances with single spring or one pair of balances with twin spring may be furnished, except that for 1%-inch sash not oyer 2 feet 10% inches wide, or with glass not over 30 inches wide, one pair of balances with single spring or one twin spring balance shall be furnished, for each pair of sash, provided a suitable equalizer for each sash is furnished.
A-20. Casement windows, each to have:
Butts, type 2015% (for casement opening out—type 2031A).
2	only surface bolts, type 1060—6-inch (for pairs, casements only). 1 only casement fastener, Yale & Towne No. 1067 or equal with wrought or cast base.
1	only casement adjuster, type 1002A (1 to each sash); 2 steel casement pivots as described below may be used in lieu of butts and casement adjuster. Pivot may consist of sill plate, sash plate, arm and sliding shoe, as manufactured by Vincent Whitney Co. or equal.
A-21. Small size access doors, each to have:
1	pair butts, type 2018%.
7	cabinet lock, type 701A.
A-22. Scuttles, each to have:
1	pair hinges 2240.
1	only scuttle fastener, type A1148, except japanned.
A-23. Outside window wire grilles.—1 only padlock Id or lb with chain as for Id, size 1% inches.
A-24. Window screens, each to have:
1	pair screen hangers, type 1825 or 1825B, except japanned.
1	hook and eye, type 1601C, 1% inches, except japanned.
37
A-25. Screen doors, each to have:
1	pair of 2031A.
2	only surface bolts, 1060—6-inch (pairs of doors only).
1	catch, type 1086A.
A-26. Sliding, folding, partition doors.—Hardware may be similar to Richards-Wilcox folding partition door hardware 237, complete with track, hangers, brackets, floor guide, track stops, butts, bolts, etc. Lock sets shall be type 97 x knob 210 x rose 330A x cast flush cop, approximately 3 inches in diameter with ring.
A-27. Water closet stall doors, each to have (where metal partitions are used, this paragraph need not be used):
(a) Partitions without hanging stile:
1	set of hinges (1 only hinge, type 4102; 1 only hinge, type 4102A).
1 strike, type 4315.
1	bolt, type C1051.
(&)	Wood partitions:
1	pair spring hinges, type 2302.
1	latch, type 4301 without keeper.
1	strike, with keeper similar to Chicago Spring Hinge Co.’s type 1345C.
(c) Partitions witn hanging stile:
1	set of hinges (1 only hinge, type 4102; 1 only hinge, type 4101A).
1	latch and strike with keeper, type 4301A.
A-28. Push plates shall be either glass or plastic—beveled.
SECTION B. OFFICE, ADMINISTRATION, INSTRUCTION, FIRST-AID BUILDINGS, GUARD HOUSES, ETC.
B-l. Pairs, exterior entrance doors, each pair to have:
Butts, type 2010%.
1	set fire exit bolts J5391L, active leaf; J5344L, inactive leaf, Sargent & Co. or equal.
2	surface door closers.
B-2. Single, exterior doors, not otherwise specified, each door to have:
Butts, type 2010%.
1	set fire exit bolts J5391L, Sargent & Co. or equal.
1	surface door closer.
B-3. Pairs or single doors to or from vestibules, lobby, stair hall, reception rooms, toilet and toilet vestibules, locker rooms, cafeterias, each door to have:
Butts, type 2010%.
1	door pull, type 452.
1 push plate, type 461 (approximate size 14 x 3% inches, glass or plastic).
1	surface door closer.
1	door stop as limited.
38
B-4. Single doors to or from offices and dll other interior doors not otherwise limited, each door to have:
Butts, type 2010% for corridor doors to offices only; type 2015% for all other doors.
1 set locks, type 97 x knobs 210 x rose 330A.
1 door stop as limited.
B-5. Single communicating doors between offices, each door to have:
Butts, type 2015%.
1 set locks, type 20 x knobs 210 x rose 330A x 2 turn knobs.
1 door stop as limited.
B-6. Single doors to or from closets, pipe shafts, slop sinks, each door to have:
Butts, type 2015%.
1	set latches, type 28 x knobs 210 x rose 330A.
Note.—If these doors are required to'be locked, 1 dead lock, type 114 no turn knob may be used in addition to the above.
1	door stop as limited.
B-7. Single doors to or from private toilet, each door to have: Butts, type 2015%.
1	set locks, type 17A x knobs 210 x rose 330A x escutcheon 350A x 1 turn knob.
1	door stop as limited.
B-8. Single double-acting doors, each door to have:
1	set floor hinges, type 3500 or 3510, size as indicated.
Note.—If jamb D. A. hinges are required in lieu of floor hinges, 1 pair jamb hinges, type 2330A, size as indicated in proper table may be used.
2	push plates, type 461, approximate size 14x3% inches, glass or plastic.
Note.—If these doors are required to be locked, 1 only dead lock, type 115 may be used in addition to the above.
CAFETERIA BUILDINGS
B-9. Pairs exterior entrance doors, each door to have: Butts, type 2010%.
1	set fire exit bolts J5391L, active leaf; J5344L, inactive leaf, Sargent & Co. or equal.
1	surface door closer.
B-10. Pairs and single interior doors to or from vestibule, serving rooms, toilets and toilet vestibule, cafeteria, dishwashing room, each door to have:
Butts, type 2010%.
1	door pull, type 452.
1	push plate, type 461, approximate size 14 x 3% inches, glass or plastic.
1	surface door closer.
1	door stop as limited.
39
B-ll. In and out doors, each door to have:
Butts, type 2010%.
1	push plate, type 461, approximate size 14 x 3% inches, glass or plastic.
1	surface door closer.
1	dead lock, type 115.
B-12. All other interior doors not otherwise specified, each to have: Butts, type 2015%.
1	set locks, type 97 x knobs 210 x rose 330A.
1	door stop as limited.
B-13. Single double-acting doors, each door to have:
1	pair D. A. jamb hinges 2330A, size as indicated.
Note.—If floor hinges are required in lieu of jamb hinges, 1 set floor hinges type 3500 or 3510, size as indicated in proper table may be used.
Jamb hinges must be omitted.
2	push plates, type 461, approximate size 14 x 3% inches, glass or or plastic.
Note.—If any of these doors are required to be locked, 1 only dead lock, type 115 may be used in addition to the above.
SECTION C. ASSEMBLY EXPLOSIVE LOADING, PACKING, SCREENING, DETONATOR LOADING, PELLITING, MAGAZINE, POWDER BUILDINGS, BLENDING MIXING BUILDINGS, TRACER AND HIGH EXPLOSIVE PRESS LOADING BUILDINGS, TRACER IGNITER AND INCENDIARY BUILDINGS, MELTING AND POURING BUILDINGS, DRILLING AND THREAD CLEANING BUILDINGS, PERCUSSION ELEMENT LINE BUILDINGS, PRELIMINARY DRY HOUSES, CHANGE BUILDINGS
In any part of these buildings, where the presence of static electricity would constitute a hazard, the following items of hardware may be furnished in solid brass—Subject to appeal under Copper Order M-9-c.
C-l. Pairs exterior entrance doors, each pair to have:
Butts, type 2010%.
1	dead lock, type 115.
2	flush bolts, type 1044B.
2	door pulls, type 452.
2	push plates, type 461, approximately size 14 x 3% inches, glass or plastic.
2	surface door closers.
Note.—On fuse and shell loading plants change paragraph B-14 to read as follows: Pairs exterior entrance doors, each pair to have:
Butts, type 2010%.
1	set fire exit bolts J5391L, active leaf; J5344L, inactive leaf, Sargent & Co. or equal.
2	surface door closers.
C-2. Pairs and single vestibule and toilet room doors, each to have: Butts, type 2010%.
1	door pull, type 452.
40
1	push plate, type 461, approximate size 14 x 3% inches, glass or plastic.
1	surface type door closer.
C-3. Pairs safety doors, each pair to have:
Butts, type 2015%.
4	door pulls, type 1274.
3	special safety catches.
C-4. Single and pairs D. A. jamb doors, each pair to have:
1	pair L). A. jamb hinge, type 2330A, size as indicated in proper table.
2	push plates, type 461, approximate size 14 x 3% inches.
C-5. Other single interior doors, not otherwise specified., each door to have:
Butts, type 2010%.
1	set locks, type 97 x knobs 210 x rose 330A.
1	door stop type as limited.
C-6. Single and pairs all sliding doors.—1 only padlock, type 1A 2-inch, unpolished.
C-7. Hinged fence gates, each gate to have:
1	only padlock, type 1A, 2-inch unpolished.
SECTION D. ORDNANCE AND FACTORY BUILDINGS, POWERHOUSE, WAREHOUSES, FIRE HOUSE, PUMP HOUSE, AND SHIPPING ROOM BUILDINGS
D-l. Pairs exterior entrance doors, each pair to have:
Butts, type 2010%.
2	flush bolts, type 1044B.
1	set locks, type 97 x knobs 210 x rose 330A.
1	surface door closer.
D-2. Single exterior entrance door, each door to have:
Butts, type 2010%.
1	set locks, type 97 x knobs 210 x rose 330A.
1	surface door closer.
D-3. Pairs of single doors to or from vestibule, lobby, toilet and vestibule, stair hall, each door to have:
Butts, type 2010%.
1	door pull, type 452.
1	push plate, type 461, approximate size 14 x 3% inches, glass or plastic.
1	surface door closer.
D-4. Single interior doors to or from offices and other doors not otherwise specified, each door to have:
Butts, type 2010%.
1	set locks, type 97 x knobs 210 x rose 330A.
1	door stop as limited,
D-5. Single interior doors to or from closets, storage rooms, each door to have:
Butts, type 2015%.
41
1 set latches, type 28 x knobs 210 x rose 330A.
Note.—If these openings are required to be locked, 1 only dead lock type 114 may be used in addition to the above.
1 door stop as limited.
D-6. Pairs large factory type interior and exterior hinged doors, each pair to have:
3 pairs strap hinges, type 2138, except japanned, size 24 inches for doors 3 feet wide and under, size 36 inches for doors over 3 feet.
1 chain bolt, type 1022B, 8-inch.
1 cane-bolt, type 1051A, 19-inch plain steel rod.
1 thumb latch, type 1189A.
1 pair padlock eyes, type 1430, except japanned.
1	padlock, type 1A, 2-inch unpolished.
2	only overhead door holders, type B, 1154A, japanned only.
D-7. Single large factory-type interior and exterior hinged doors, each door to have:
1^2 Pair strap hinges, type 2138, except japanned, size 24 inches for doors 3 feet wide and under, size 36 inches for doors over 3 feet.
1 only thumb latch, type 1189A.
1	pair padlock eyes, type 1430, except japanned.
1	only padlock, type 1A, 2-inch unpolished.
1	only overhead door holder, type B-1154A, japanned only.
D-8. Sliding doors, each door to have track, standard box or tubular design with brackets, stops, etc., for complete installation. Two hangers per leaf. Brackets for track spaced approximately 24 inches o. c. Hangers of wrought steel, malleable iron, or drop-forged steel." Hanger track may be of cast iron. Rollers may be mounted on ball or roller bearings.
Table
Doors	Track, min.		Wheel diameter, min.	
	Box	Round	Box	Rd.
Up to 350 pounds		1% x 2 inches x 16 gage			 1%	1%	Inches 1%6
350 to 600 pounds		2Mb x 3% inches x 14 gage. _			2^	3	274
600 to 900 pounds		2% x 3% inches x 13 gage				2/2	3	274
900 to 1,200 pounds		2% x 3% inches x 10 gage			 2H	3	274
2,000 pounds and over		2% x 4% x 9 gage			4	—
Note.—12-gage track 2^6 x 3% inches with brackets 18 inches on centers may be used for doors of 600 to 800 pounds, and with brackets 12 inches on centers for doors 800 to 1,000 pounds.
Hasp, 6-inch, type 1420.
Padlock, 1%-incn, type Id or type lb with chain as normally used for Id.
Stay rollers, type 55 Richards-Wilcox catalog, or equal.
42
D-8a. Upward-acting sectional doors.—Hardware to be of ferrous type except cylinder and keys for locking mechanism.
D-8b. Motor control for operation of doors may be used only where conditions are such as to make manual operation impractical.
D-8c. Upward-acting solid-type doors.—Hardware to be of ferrous type, except cylinder and keys for locking mechanism.
SECTION E. OFFICERS’ QUARTERS
E-l. The following limitations apply to senior officers’ quarters, commanding officers’ quarters, field officers’ quarters, miscellaneous officers’ quarters other than bachelor officers, noncommissioned officers’ quarters. See also section A.
E-2. All single exterior entrance doors, each door to have:
Butts, type 2015%.
1	set locks, type 97 x knobs 210 x rose 330A.
1	door stop, type A1336.
E-3. All single exterior doors to or from porches and terraces, not including main entrance doors, each door to have:
Butts, type 2015%.
1	set locks, type 17A x knobs 210 x rose 330A x turn knob.
1	door stop, type A1336.
E-4. Single D. A. doors, each door to have:
1 set floor hinges, type 2334.
2 push plates, approximate size 14 x 3% inches, glass or plastic.
E-5. Single exterior sliding doors, each door to have:
Track 465 Knape & Vogt or equal, length as required.
2 sheaves 413 Knape & Vogt or equal.
2 pulls 1108 Russell & Erwin Mfg. Co. or equal.
2 flush bolts 191 Russell & Erwin Mfg. Co. or equal.
E-6. Single interior sliding doors, each door to have:
Track 465 Knape & Vogt or equal, length as required.
2 sheaves 413 Knape & Vogt or equal.
1 sliding door pull 075 Russell & Erwin Mfg. Co. or equal.
2 flush pulls 1108 Russell & Erwin Mfg. Co. or equal.
E-7. Sliding wardrobe doors, each to have:
Track 990% P. & F. Corbin or equal, length as required.
2 sheaves BB753% P. & F. Corbin or equal.
1	sliding door pull 075 Russell & Erwin Mfg. Co. or equal.
1	flush pull 1108 Russell & Erwin Mfg. Co. or equal.
E-8. Single doors to or from storage rooms, bedrooms, study, library, each door to have:
Butts, type 2015%.
1	set locks, type 4A x knobs 210 rose 330A x escutcheon 350A.
1	door stop, type A1336.
E-9. All other interior doors not otherwise mentioned, each door to have
Butts type 2015%.
1	set latches, type 28 x knobs 210 x rose 330A (a latch similar to type 28 except with single compression spring, front approxi
43
mately size 3% x 1^ inches, case 1% x 3% x inches may be used).
1 door stop, type 1336.
E-10. Single doors to or from bathroom and toilets, each door to have
Butts, type 2015%.
1	set locks, type 17A x knobs 210 x rose 330A x escutcheon 350A x turn knob.
1	door stop, type A1336.
E-ll. Sliding sash, each to have:
Track 990% P. & F. Corbin or equal, length as required.
2	sheaves BB-753% P. & F. Corbin or equal.
2	flush pulls 1108 Russell & Erwin Mfg. Co. or equal.
E-12. Alternate locks for interior doors. Locks and latches of rim, tubular, or cylindrical case types may be used for interior doors as shown below.
Item specified, mortise	Alternates		
	Rim	Tubular	Cylindrical case
4A—except for						150, 153	164
17A, 4A for bedrooms		59	' 151	162
28		59	150	160
Screen-door catch: Latch with tubular case approximately % inch in diameter, 1% inches backset.
F-l. The following requirements apply to bachelors officers’ quarters, administration buildings, recreation buildings, operation and message center, mess hall, galley and commissary, barrack buildings, and boathouse. (See also section A.)
F-2. Pairs exterior entrance doors, each pair to have:
Butts, type 2010%.
If single-acting floor hinges are required in lieu of butts and door closer, 2 floor hinges, type 3520A, size as indicated in proper table may be used. Butts, door closers, and brackets must be omitted.
1	dead lock, type 115.
2	flush bolts, type 1044B.
2	surface door closers.
2	door pulls, type 452.
2	push plates, type 461, approximately 14 x 3% inches, glass or plastic.
F-3. Single exterior entrance doors, each door to have:
Butts, 2010%.
If single-acting floor hinges are required in lieu of butts and door closers, 1 floor hinge, type 3520A, size as indicated in proper table may be used. Butts, door closers, and brackets must be omitted.	*	,
1	dead lock, type 115.	/_ .	< ;
14
1	surface door closer.
1	door pull 452.
1	push plate 461, approximately 14 x 3% inches, glass or plastic.
F-4. Pairs of exterior doors opening out of the assembly halls, auditoriums, etc., each door to have :
Butts, type 2010%.
1	fire-exit bolt, J5344L, Sargent catalog, or equal, each leaf.
2	surface door closers.
F-5. All other single exterior doors not otherwise mentioned, each door to have :
Butts, type 2010%.
1	set locks, type 97 x knobs 210 x rose 330A.
1	surface door closer.
F-6. Single doors to or from vestibule, lobby, stair hall, dormitories, toilets and toilet vestibules, locker shower rooms, and doors between corridors, each door to have :
Butts, type 2010%.
1	door pull, type 452.
1 push plate, approximate size 14 x 3% inches, glass or plastic.
1 surface door closer.
1 door stop as limited.
F-7. Single doors to or from gamerooms, recreation, cardrooms, gymnasium, mess halls, and kitchens, each door to have :
Butts, type 2010%.
1 dead lock, type 115.
1	door pull, type 452.
1	push plate, approximate size, 14 x 3% inches, glass or plastic.
1	surface door closer.
1	door stop as limited.
F-8. Single doors to or from private toilets and lavatories, each door to have :
Butts, type 2015%.
1	set locks, type 17A x knobs 210 x rose 330A x escutcheon 350A x turn knob.
1	door stop as limited.
F-9. Single doors, corridor to or from heater, radio, equipment, electric, cleaning gear, conference, clerks', aerological, telephone and telegraph exchange, switch, transformer, shops, repair, and projection rooms, each door to have :
Butts, type 2010%.
1	set locks, type 97 x knobs 210 x rose 330A.
1	door stop as limited.
F-10. Single-convmunicating doors between offices, each door to have:
Butts, type 2015%.
1	set locks, type 20 x knobs 210 x rose 330A x 2-turn knobs.
1	door stop as limited.
F-ll. Single doors to or from storage rooms and all other interior doors not otherwise mentioned, each door to have :
Butts, type 2015%.
45
1	set locks, type 97 x knobs 210 x rose 330A.
1	door stop as limited.
F-12. Single doors from closets, slop sinks, pipe shafts, equipment access doors, each door to have :
Butts, type 2015^.
1	set latches, type 28 x knobs 210 x rose 330A.
Note.—If it is required to equip these doors with a cylinder lock, 1 only dead lock, type 114, no turn knob, may be used in addition to above.
1	door stop as limited.
F-13. Single double-acting doors, each to have :
1 set floor hinges, type 3500 or 3510, size as required.
Note.—If jamb D. A. hinges are required in lieu of floor hinges, 1 pair hinges 2330A may be used.