[Federal Register Volume 85, Number 82 (Tuesday, April 28, 2020)]
[Notices]
[Pages 23540-23542]
From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
[FR Doc No: 2020-08925]
-----------------------------------------------------------------------
NUCLEAR REGULATORY COMMISSION
[Docket No(s). 72-1031; 72-1037; 72-64; 72-38; and 72-45; NRC-2020-
0092]
ZionSolutions LLC; Dominion Energy Kewaunee, Inc.; Duke Energy
Carolinas, LLC
AGENCY: Nuclear Regulatory Commission.
ACTION: Exemptions; issuance.
-----------------------------------------------------------------------
SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) issued four
exemptions in response to requests from ZionSolutions LLC; Dominion
Energy Kewaunee, Inc.; and Duke Energy Carolinas, LLC. The exemptions
allow the licensees to deviate from the requirements for the
MAGNASTOR[supreg] storage cask system in Certificate of Compliance No.
1031, Amendment No. 7 (for Catawba and McGuire) and Amendment No. 6
(for Zion and Kewaunee), by utilizing two exceptions to the American
Society of Mechanical Engineers Boiler and Pressure Vessel Code. The
NRC is issuing a single notice to announce the issuance of these
exemptions because these are nearly identical.
DATES: The four exemptions were issued on April 21, 2020.
ADDRESSES: Please refer to Docket ID NRC-2020-0092 when contacting the
NRC about the availability of information regarding this document. You
may obtain publicly-available information related to this document
using any of the following methods:
Federal Rulemaking website: Go to https://www.regulations.gov and search
[[Page 23541]]
for Docket ID NRC-2020-0092. Address questions about NRC dockets IDs in
Regulations.gov to Jennifer Borges; telephone: 301-287-9127; email:
[email protected]. For technical questions, contact the
individual(s) listed in the FOR FURTHER INFORMATION CONTACT section of
this document.
NRC's Agencywide Documents Access and Management System
(ADAMS): You may obtain publicly-available documents online in the
ADAMS Public Documents collection at https://www.nrc.gov/reading-rm/adams.html. To begin the search, select ``Begin Web-based ADAMS
Search.'' For problems with ADAMS, please contact the NRC's Public
Document Room (PDR) reference staff at 1-800-397-4209, 301-415-4737, or
by email to [email protected].
For the convenience of the reader, instructions about obtaining
materials referenced in this document are provided in the
``Availability of Documents'' section.
FOR FURTHER INFORMATION CONTACT: Bernard White, U.S. Nuclear Regulatory
Commission, Washington, DC 20555-0001; telephone: 301-415-6577, email:
[email protected].
SUPPLEMENTARY INFORMATION:
I. Introduction
The NRC issued four exemptions in response to requests dated
December 30, 2019, January 16, 2020, and January 9, 2020, from
ZionSolutions LLC; Dominion Energy Kewaunee, Inc.; Duke Energy
Carolinas, LLC, respectively. The exemptions allow exemption from the
requirements of title 10 of the Code of Federal Regulations (10 CFR)
sections 72.212(a)(2), 72.212(b)(3), 72.212(b)(5)(i), 72.214, and the
portion of 10 CFR 72.212(b)(11), which requires compliance with the
terms and conditions set forth in the certificate of compliance for
each spent fuel cask used by an independent spent fuel storage
installation general licensee.
The exemptions requested use of two exceptions to the American
Society of Mechanical Engineers Boiler and Pressure Vessel Code, one
for the Section III, Division 1, Subsection NG-2300, Charpy V-notch
testing direction requirement for carbon steel plate material greater
than 0.625 inches thick and the other to the post-heat treatment
ultrasonic testing requirements in Section III, Division 1, Subsection
NG-2500, for rolled carbon steel plate material greater than 0.75
inches thick. The requested exemptions do not change the fundamental
design, components, contents, or safety features of the storage system.
II. Availability of Documents
The table below provides the plant name, docket number, and ADAMS
Accession Numbers related to this action. For further details with
respect to these exemptions, see the requests for exemption for each
facility in ADAMS. For additional direction on accessing information
related to this document, see the ADDRESSES section of this document.
------------------------------------------------------------------------
ADAMS Accession
Document title No.
------------------------------------------------------------------------
ZionSolutions Independent Spent Fuel Storage Installation
Docket No. 72-1037
------------------------------------------------------------------------
Request for an Exemption to the Requirements of ML20003D845
Certificate of Compliance No. 1031, Amendment No. 6
for the NAC MAGNASTOR Storage System Zion Nuclear
Power Station, Units 1 and 2 Facility Operating
License Nos. DPR-39 and DPR-48 NRC Docket Nos. 50-295
and 50-304 Independent Spent Fuel Storage
Installation Docket No. 72-1037......................
Revised Request for an Exemption to the Requirements ML20035E402
of Certificate of Compliance No. 1031 Amendment No. 6
for the NAC MAGNASTOR Storage System Zion Nuclear
Power Station, Units 1 and 2 Facility Operating
License Nos. DPR-39 and DPR-48 NRC Docket Nos. 50-295
and 50-304 Independent Spent Fuel Storage
Installation Docket No. 72-1037......................
Response to NRC Request for Additional Information for ML20076C526
MAGNASTOR Basket Material Investigation for NAC CARs
19-01 and 19-02......................................
Issuance of Exemption for Zion Independent Spent Fuel ML20098E710
Storage Installation.................................
------------------------------------------------------------------------
Catawba Independent Spent Fuel Storage Installation
Docket No. 72-45
------------------------------------------------------------------------
Request for an Exemption to the Requirements of ML20009E527
Certificate of Compliance No. 1031, Amendment No. 7
for the NAC MAGNASTOR Storage System.................
Response to Requests for Additional Information for ML20072M224
Exemption Request to the Requirements of Certificate
of Compliance No. 1031, Amendment No. 7 for the NAC
MAGNASTOR Storage System.............................
Issuance of Exemption for Catawba Independent Spent ML20098D956
Fuel Storage Installation............................
------------------------------------------------------------------------
McGuire Independent Spent Fuel Storage Installation
Docket No. 72-38
------------------------------------------------------------------------
Request for an Exemption to the Requirements of ML20009E527
Certificate of Compliance No. 1031, Amendment No. 7
for the NAC MAGNASTOR Storage System.................
Response to Requests for Additional Information for ML20072M224
Exemption Request to the Requirements of Certificate
of Compliance No. 1031, Amendment No. 7 for the NAC
MAGNASTOR Storage System.............................
Issuance of Exemption for McGuire Independent Spent ML20098C982
Fuel Storage Installation............................
------------------------------------------------------------------------
Kewaunee Independent Spent Fuel Storage Installation
Docket No. 72-38
------------------------------------------------------------------------
Dominion Energy Kewaunee, Inc. Kewaunee Power Station ML20035C759
Request for Exemption from Certain Code of Federal
Regulation Requirements of Certificate of Compliance
No. 1031, Amendment No. 6 for the NAC MAGNASTOR
Storage System.......................................
Dominion Energy Kewaunee, Inc. Kewaunee Power Station ML20086K860
Application for Exemption-MAGNASTOR Storage System
Response to Request for Additional Information.......
Issuance of Exemption for McGuire Independent Spent ML20098D404
Fuel Storage Installation............................
------------------------------------------------------------------------
[[Page 23542]]
The NRC may post additional materials to the Federal rulemaking
website at https://www.regulations.gov, under Docket ID NRC-2020-0092.
The Federal rulemaking website allows you to receive alerts when
changes or additions occur in a docket folder. To subscribe: (1)
Navigate to the docket folder (NRC-2020-0092); (2) click the ``Sign up
for Email Alerts'' link; and (3) enter your email address and select
how frequently you would like to receive emails (daily, weekly, or
monthly).
Dated: April 22, 2020.
For the Nuclear Regulatory Commission.
John B. McKirgan,
Chief, Storage and Transportation Licensing Branch, Division of Fuel
Management, Office of Nuclear Material Safety and Safeguards.
[FR Doc. 2020-08925 Filed 4-27-20; 8:45 am]