[Federal Register Volume 84, Number 183 (Friday, September 20, 2019)]
[Rules and Regulations]
[Pages 49435-49439]
From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
[FR Doc No: 2019-19965]



========================================================================
Rules and Regulations
                                                Federal Register
________________________________________________________________________

This section of the FEDERAL REGISTER contains regulatory documents 
having general applicability and legal effect, most of which are keyed 
to and codified in the Code of Federal Regulations, which is published 
under 50 titles pursuant to 44 U.S.C. 1510.

The Code of Federal Regulations is sold by the Superintendent of Documents. 

========================================================================


Federal Register / Vol. 84, No. 183 / Friday, September 20, 2019 / 
Rules and Regulations

[[Page 49435]]



CONSUMER PRODUCT SAFETY COMMISSION

16 CFR Part 1215

[Docket No. CPSC-2009-0064]


Revisions to Safety Standard for Infant Bath Seats

AGENCY: Consumer Product Safety Commission.

ACTION: Direct final rule.

-----------------------------------------------------------------------

SUMMARY: In December 2013, the U.S. Consumer Product Safety Commission 
(CPSC) published an update to the consumer product safety standard for 
infant bath seats. The standard incorporated by reference the 
applicable ASTM voluntary standard. ASTM has since published two 
revised versions of the voluntary standard for infant bath seats. We 
are publishing this direct final rule revising the CPSC's mandatory 
standard for infant bath seats to incorporate by reference, the most 
recent version of the applicable ASTM standard.

DATES: The rule is effective on December 22, 2019, unless we receive 
significant adverse comment by October 21, 2019. If we receive timely 
significant adverse comments, we will publish notification in the 
Federal Register, withdrawing this direct final rule before its 
effective date. The incorporation by reference of the publication 
listed in this rule is approved by the Director of the Federal Register 
as of December 22, 2019.

ADDRESSES: You may submit comments, identified by Docket No. CPSC-2009-
0064, by any of the following methods:
    Electronic Submissions: Submit electronic comments to the Federal 
eRulemaking Portal at: https://www.regulations.gov. Follow the 
instructions for submitting comments. The CPSC does not accept comments 
submitted by electronic mail (email), except through 
www.regulations.gov. The CPSC encourages you to submit electronic 
comments by using the Federal eRulemaking Portal, as described above.
    Written Submissions: Submit written submissions in the following 
way: Mail/Hand delivery/Courier (for paper, disk, or CD-ROM 
submissions), preferably in five copies, to: Division of the 
Secretariat, Consumer Product Safety Commission, Room 820, 4330 East 
West Highway, Bethesda, MD 20814; telephone (301) 504-7923.
    Instructions: All submissions received must include the agency name 
and docket number for this proposed rulemaking. All comments received 
may be posted without change, including any personal identifiers, 
contact information, or other personal information provided, to: 
https://www.regulations.gov. Do not submit confidential business 
information, trade secret information, or other sensitive or protected 
information that you do not want to be available to the public. If 
furnished at all, such information should be submitted in writing.
    Docket: For access to the docket to read background documents or 
comments received, go to: www.regulations.gov, and insert the docket 
number, CPSC-2009-0064, into the ``Search'' box, and follow the 
prompts.

FOR FURTHER INFORMATION CONTACT: Keysha Walker, Compliance Officer, 
Office of Compliance and Field Operations, Consumer Product Safety 
Commission, 4330 East West Highway, Bethesda, MD 20814-4408; telephone: 
301-504-6820; email: [email protected].

SUPPLEMENTARY INFORMATION: 

A. Background

1. Statutory Authority

    Section 104(b)(1)(B) of the Consumer Product Safety Improvement Act 
(CPSIA), also known as the Danny Keysar Child Product Safety 
Notification Act, requires the Commission to promulgate consumer 
product safety standards for durable infant or toddler products. The 
law requires these standards to be ``substantially the same as'' 
applicable voluntary standards or more stringent than the voluntary 
standards if the Commission concludes that more stringent requirements 
would further reduce the risk of injury associated with the product.
    The CPSIA also sets forth a process for updating CPSC's durable 
infant or toddler standards when the voluntary standard, upon which the 
CPSC standard was based, is changed. Section 104(b)(4)(B) of the CPSIA 
provides that if an organization revises a standard that has been 
adopted, in whole or in part, as a consumer product safety standard 
under this subsection, it shall notify the Commission. In addition, the 
revised voluntary standard shall be considered to be a consumer product 
safety standard issued by the Commission under section 9 of the 
Consumer Product Safety Act (15 U.S.C. 2058), effective 180 days after 
the date on which the organization notifies the Commission (or such 
later date specified by the Commission in the Federal Register) unless, 
within 90 days after receiving that notice, the Commission notifies the 
organization that it has determined that the proposed revision does not 
improve the safety of the consumer product covered by the standard and 
that the Commission is retaining the existing consumer product safety 
standard.

2. The Infant Bath Seats Standard

    On June 4, 2010, the Commission published a final rule issuing a 
standard for infant bath seats that incorporated by reference the 
standard in effect at that time, ASTM F1967-08a, Standard Consumer 
Specification for Infant Bath Seats, with certain modifications to make 
the standard more stringent. 75 FR 31691. The standard was codified in 
the Commission's regulations at 16 CFR part 1215. The ASTM standard has 
been revised twice since the rule issued, with the Commission 
incorporating by reference, ASTM F1967-11a (77 FR 45242, Jul. 31, 
2012), and ASTM F1967-13 (78 FR 73692, Dec. 9, 2013), respectively.
    Since December 2013, when the CPSC incorporated by reference ASTM 
F1967-13 as the mandatory standard for infant bath seats, ASTM 
published two additional revisions to the standard. On June 25, 2019, 
ASTM notified the Commission that it has revised ASTM's standard for 
infant bath seats. The current ASTM standard is ASTM F1967-19, Standard 
Consumer Safety Specification for Infant Bath Seats, approved May 1, 
2019. The CPSC reviewed the changes between the current CPSC standard, 
16 CFR part

[[Page 49436]]

1215 and the two revisions to the standard (ASTM F1967-18 and ASTM 
F1967-19) since ASTM F1967-13 became mandatory. ASTM did not notify 
CPSC of the publication of the 2018 version of the standard because 
ASTM was considering making additional changes in 2019. Consequently, 
ASTM notified CPSC of the 2019 revision to the standard, which included 
the changes in the 2018 version of the standard.

B. Revisions to the ASTM Standard

    The ASTM standard for infant bath seats establishes performance 
requirements, test methods, and labeling requirements to address 
hazards to children associated with infant bath seats, including 
stability, restraints, suction cups, latching and locking mechanisms, 
and resistance to collapse. Products commonly referred to as bath rings 
also are included in the scope of this specification. Traditional 
infant bath tubs that are used to bathe an infant are not within the 
scope of this standard.
    Under section 104(b)(4)(B) of the CPSIA, unless the Commission 
determines that ASTM's revision to a voluntary standard that is a CPSC 
mandatory standard ``does not improve the safety of the consumer 
product covered by the standard,'' the revised voluntary standard 
becomes the new mandatory standard. As discussed below, the Commission 
determines that the changes made in ASTM F1967-19 will either improve 
the safety of infant bath seats or are neutral with respect to safety. 
Therefore, the Commission will allow the revised voluntary standard to 
become effective as a mandatory consumer product safety standard under 
the statute, effective December 22, 2019.
    There are several differences between the current CPSC standard 16 
CFR part 1215 (ASTM F1967-13) and the two subsequent revisions to the 
standard (ASTM F1967-18 and ASTM F1967-19). We summarize the 
differences and the CPSC's assessment of the revisions below.
1. Differences Between 16 CFR Part 1215 and ASTM F1967-18
    The major revisions made in ASTM F1967--18 are summarized below. 
ASTM F1967-18 includes several changes that improve safety by 
clarifying testing. ASTM also made several editorial changes, such as 
spacing, formatting, re-ordering, and renumbering, which do not change 
the safety of the infant bath seats.
a. Scope
    The 2018 version of the ASTM standard adds language (Section 1.5), 
which ASTM intends to add to all of its standards, stating that ASTM 
developed the standard in accordance with principles recognized by the 
World Trade Organization. We conclude that adding this text does not 
change the safety of infant bath seats.
b. Terminology
    The 2018 revision to the standard adds four new definitions to 
address changes the ASTM subcommittee made to achieve consistency 
across juvenile product safety standards, including defining the terms 
``conspicuous,'' ``double action release system,'' ``installation 
components,'' and ``protective component.'' Of these new terms, the 
definition of ``double action release system'' is significant because 
it clarifies the actions and the sequence necessary for a release 
mechanism to be considered a double action release mechanism. 
Accordingly, we determine that this new definition improves the safety 
of infant bath seats. The other new definitions are neutral to the 
safety of infant bath seats.
c. General Requirements
    Section 5 General Requirements contains a number of minor editorial 
adjustments. The Commission considers these changes to be neutral to 
the safety of infant bath seats. ASTM also added section 5.10, to 
state: ``Infant bath seats must comply with applicable requirements of 
the Consumer Product Safety Improvement Act.'' The purpose of this 
statement is to alert potential manufacturers to CPSIA requirements. We 
consider this statement to be neutral to the safety of infant bath 
seats because the product must comply with CPSIA, regardless of this 
requirement in the standard.
d. Performance Requirements
    Section 6.1 Stability moves wording from an explanatory note into 
the enforceable performance requirement. Specifically, Section 6.1.2.3 
states: ``If the product would continue to tip over under the 
application of force, but it is prevented from doing so by the test 
platform interior side walls, it shall be considered a tip over.'' With 
this change to the stability performance requirement, certain types of 
contact to the tub fixture test platform are clearly identified as 
failures. This change will reduce ambiguity in testing to the standard 
and will lead to more consistent testing. We consider the reduced 
ambiguity for testing to be an improvement to safety because the 
revised language will clarify what constitutes a failure when 
conducting the testing.
    The other changes to the performance requirements in section 6 are 
editorial in nature: The changes separate the stability requirements 
and present a succinct modified decimal numbering system, as opposed to 
paragraph form. We consider these editorial changes to be neutral to 
the safety of infant bath seats.
e. Test Methods
i. Section 7.1 Latching and Locking Mechanism Tests
    Two different latching and locking test procedures (Section 7.1.1.1 
and 7.1.2.1), in the 2018 version of the standard reference a new test 
surface. The new ``Test Surface #3'' is defined as: ``(a)ny area on the 
side(s) of the test platform (for example, inside surface, outside 
surface, and top ledge), where safety tread strips are not applied.'' 
Therefore, new products that are restrained by the sides of the tub can 
now be installed and tested according to the manufacturer's 
instructions by using Test Surface #3. The changes regarding the 
definition of a new test surface reduce ambiguity in the standard and 
will lead to more consistent testing. We expect that an increase in 
testing consistency will improve the safety of bath seats.
ii. Section 7.4 Stability Test
    The 2018 ASTM standard made four changes to Section 7.4 Stability 
Test:
     The new tub fixture test platform figures correct 
dimensioning errors, add a cross-section drawing, define more clearly 
the location of the cross-sections, and add new dimensions to specify 
accurately the physical tub detailed in ASTM F1967-18 Footnote #5. 
Adding the two new cross-section drawings in this section required the 
rest of the figures in the standard to be renumbered accordingly. These 
revised fixtures correct errors and increase accuracy and clarity, 
which we expect will improve the safety of infant bath seats.
     The 2018 version of the ASTM standard adds a requirement 
for a new test surface and modifies the two existing test surfaces. The 
2013 version required testing on only two surfaces, and those two 
surfaces had to be ``. . . within the 24 in. (60.0 cm) length of 
uniform tub side ledge thickness . . . .'' The restrictive test surface 
definitions and the lack of a test surface on the side and end walls of 
the tub fixture test platform created a conflict between the test 
procedures and the manufacturer's installation instructions. New 
products

[[Page 49437]]

on the market engage with the side and end walls as part of the new 
products' retention system. To reduce potential sources of test-to-test 
and laboratory-to-laboratory variation, the ASTM subcommittee decided 
to add Test Surface #3, which addresses tub fixture test platform's 
sides and end walls as a new test surface in Section 7.4.1.2.3. The new 
language broadens the test procedures and allows for new designs of 
bath seats to be installed according to the manufacturer's 
instructions. These changes reduce ambiguity in the standard and lead 
to more consistent testing. We expect the reduced ambiguity and 
increased consistency will improve the safety of infant bath seats.
     Section 7.4.3.8 states that the 17.0 lbf applied force 
shall be perpendicular to the test bar. The 2013 revision stated that 
the force shall be horizontal. During the stability test, many products 
deflect elastically, while remaining in the initial manufacturer's 
recommended-use position. As a product deflects elastically, the test 
bar rotates in the direction of the applied force. If the test bar 
rotates, but the applied force remains horizontal, then the angle 
between the test bar and the applied force changes, reducing the torque 
applied to the sample. In contrast, the 2018 version states that the 
applied force must be perpendicular to the test bar, causing the 
applied torque to remain nominally consistent as the product deflects 
elastically. We conclude that a test that applies a consistent torque 
is a more stringent test, and therefore, this change improves the 
safety of infant bath seats.
     ASTM F1967-13 provides a formula for the baby wash 
solution that is used in testing, and states the contact information 
for a specific manufacturer of the solution. However, the company 
listed is no longer in business. ASTM F1967-18 lists two name-brand 
baby wash products readily available for purchase. We consider this 
change neutral to the safety of infant bath seats.
iii. Section 7.5 Static Load Test
    The 2018 ASTM standard also changed the static load test in section 
7.5, to reflect the new Test Surface #3. This change allows new types 
of products that are intended to be restrained by the sides of the tub, 
to be installed according to the manufacturer's instructions. Adding a 
new test surface reduces ambiguity in the standard and leads to more 
consistent testing. We consider the reduced ambiguity and increased 
consistency to improve the safety of infant bath seats.
    The second change to Section 7.5.5 requires that a product be 
tested ``. . . in all other manufacturer's recommended use positions.'' 
The revised language improves safety by requiring products be tested in 
all manufacturer's use positions, not just in one position. Typically, 
laboratories conduct testing in one position, usually what the 
laboratory considers to be the most onerous position. This can lead to 
different results from different laboratories. Adding the statement 
that testing should be ``. . . in all other manufacturer's recommended 
use positions'' will improve test-to-test and laboratory-to-laboratory 
repeatability. We consider the reduced ambiguity and increased 
consistency to improve safety.
iv. Section 7.6 Suction Cup Tests
    The suction cup test methods in section 7.6 also include the new 
Test Surface #3 and require testing of the product ``. . . in all other 
manufacturer's recommended use positions.'' As noted, testing ``in all 
other manufacturer's recommended use positons'' removes the possibility 
of different laboratories getting different testing results because of 
ambiguity. Reduced ambiguity leads to improving test-to-test and 
laboratory-to-laboratory repeatability, resulting in more consistent, 
testing which improves testing accuracy. We consider the reduced 
ambiguity and increased consistency to improve safety.
f. Marking and Labeling
    Revisions to section 8 in the 2018 standard, regarding Marking and 
Labeling, include changes to the formatting and presentation of the 
warnings. These revisions result from major changes ASTM initiated for 
juvenile products. After publishing the 2013 version of the standard, 
ASTM convened a task group, ASTM Ad Hoc Wording Task Group (Ad Hoc TG), 
consisting of members of the various durable nursery products voluntary 
standards committees, including CPSC staff. The purpose of the Ad Hoc 
TG is to harmonize the wording, as well as the warning format, across 
durable infant and toddler product voluntary standards. Ad Hoc TG 
recommendations were published as a reference document, titled, ``Ad 
Hoc Wording--May 4, 2016,'' as part of the F15 Committee Documents.
    In addition to the formatting changes, the warning statement 
required by the 2018 ASTM standard includes a personalized warning 
using the words: ``Stay in arms' reach of your baby,'' as opposed to: 
``ALWAYS keep baby within adult's reach.'' Research suggests that 
personalizing warnings and instructions increase compliance.
    The revisions in ASTM F1967--18 incorporate the Ad Hoc Wording 
recommendations. Accordingly, we consider adopting the Ad Hoc Wording 
reference document recommendations and the more personal messaging as 
improvements to safety because they provide noticeable, personalized, 
and consistent warning labels on infant bath seats.
g. Instructional Literature
    The requirements for Instructional Literature in section 9 of ASTM 
F1967-18 are expanded to include infant bath seat labeling requirements 
similar to the marking and labeling section of the standard. Staff 
considers these changes to improve the safety of bath seats because 
they provide noticeable, personalized, and consistent instructional 
literature.
2. Differences Between 16 CFR Part 1215 and ASTM F1967-19
    ASTM F1967-19 revises two sections of the standard. The first, a 
change to section 7.5.1, allows the static load tests to be conducted 
on any of the three test surfaces, rather than specify a particular 
test surface. The second update removes Footnote #6 from the ASTM 
standard. The standard already covers the same topic in Section 
7.4.1.2, and the footnote was incomplete and confusing. Both changes 
are neutral to the safety of bath seats.

C. Incorporation by Reference

    The Office of the Federal Register (OFR) has regulations concerning 
incorporation by reference. 1 CFR part 51. Under these regulations, 
agencies must discuss, in the preamble to the final rule, ways that the 
materials the agency incorporates by reference are reasonably available 
to interested persons and how interested parties can obtain the 
materials. In addition, the preamble to the final rule must summarize 
the material. 1 CFR 51.5(b).
    In accordance with the OFR's requirements, section B of this 
preamble summarizes the major provisions of the ASTM F1967-19 standard 
that the Commission incorporates by reference into 16 CFR part 1215. 
The standard is reasonably available to interested parties, and 
interested parties may purchase a copy of the standard from ASTM 
International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, 
PA 19428-2959 USA; phone: 610-832-9585; www.astm.org. A copy of the 
standard can also be inspected at CPSC's Division of the Secretariat, 
U.S. Consumer Product

[[Page 49438]]

Safety Commission, Room 820, 4330 East West Highway, Bethesda, MD 
20814, telephone 301-504-7923.

D. The Congressional Review Act

    The Congressional Review Act (CRA; 5 U.S.C. 801-808) states that, 
before a rule may take effect, the agency issuing the rule must submit 
the rule, and certain related information, to each House of Congress 
and the Comptroller General. 5 U.S.C. 801(a)(1). The submission must 
indicate whether the rule is a ``major rule.'' The CRA states that the 
Office of Information and Regulatory Affairs (OIRA) determines whether 
a rule qualifies as a ``major rule.'' Pursuant to the CRA, OIRA 
designated this rule as not a ``major rule,'' as defined in 5 U.S.C. 
804(2). In addition, to comply with the CRA, the Office of the General 
Counsel will submit the required information to each House of Congress 
and the Comptroller General.

E. Certification

    Section 14(a) of the CPSA requires that products subject to a 
consumer product safety rule under the CPSA, or to a similar rule, ban, 
standard, or regulation under any other act enforced by the Commission, 
be certified as complying with all applicable CPSC requirements. 15 
U.S.C. 2063(a). Such certification must be based on a test of each 
product, or on a reasonable testing program, or, for children's 
products, on tests on a sufficient number of samples by a third party 
conformity assessment body accredited by the Commission to test 
according to the applicable requirements. As noted, standards issued 
under section 104(b)(1)(B) of the CPSIA are ``consumer product safety 
standards.'' Thus, they are subject to the testing and certification 
requirements of section 14 of the CPSA.
    Because infant bath seats are children's products, samples of these 
products must be tested by a third party conformity assessment body 
whose accreditation has been accepted by the Commission. These products 
also must comply with all other applicable CPSC requirements, such as 
the lead content requirements in section 101 of the CPSIA, the tracking 
label requirement in section 14(a)(5) of the CPSA, and the consumer 
registration form requirements in section 104(d) of the CPSIA.

F. Notice of Requirements

    In accordance with section 14(a)(3)(B)(iv) of the CPSIA, the 
Commission has previously published a notice of requirements (NOR) for 
accreditation of third party conformity assessment bodies for testing 
infant bath seats (75 FR 31688, September 4, 2010). The NOR provided 
the criteria and process for our acceptance of accreditation of third 
party conformity assessment bodies for testing infant bath seats to 16 
CFR part 1215. The NORs for all mandatory standards for durable infant 
or toddler products are listed in the Commission's rule, ``Requirements 
Pertaining to Third Party Conformity Assessment Bodies,'' codified at 
16 CFR part 1112.
    CPSC staff from the Directorate for Laboratory Sciences, Division 
of Mechanical Engineering, analyzed testing revisions to the infant 
bath seat standard and found that the revised tests use existing 
equipment and similar testing protocols. Testing laboratories that have 
demonstrated competence for testing in accordance with ASTM F1967-13 
will have the competence to test in accordance with the revised 
standard ASTM F1967-19. Therefore, the Commission considers the 
existing CPSC-accepted laboratories for testing to ASTM F1967-13 to be 
capable of testing to ASTM F1967-19 as well. Therefore, the Commission 
considers the existing accreditations that the Commission has accepted 
for testing to this standard also to cover testing to the revised 
standard. Accordingly, the existing NOR for this standard will remain 
in place, and CPSC-accepted third party conformity assessment bodies 
are expected to update the scope of the testing laboratories' 
accreditation to reflect the revised standard in the normal course of 
renewing their accreditation.

G. Direct Final Rule Process

    The Commission is issuing this rule as a direct final rule. 
Although the Administrative Procedure Act (APA) generally requires 
notice and comment rulemaking, section 553 of the APA provides an 
exception when the agency, for good cause, finds that notice and public 
procedure are ``impracticable, unnecessary, or contrary to the public 
interest.'' 5 U.S.C. 553(b)(B). The Commission concludes that when the 
Commission updates a reference to an ASTM standard that the Commission 
has incorporated by reference under section 104(b) of the CPSIA, notice 
and comment is not necessary.
    Under the process set out in section 104(b)(4)(B) of the CPSIA, 
when ASTM revises a standard that the Commission has previously 
incorporated by reference as a Commission standard for a durable infant 
or toddler product under section 104(b)(1)(b) of the CPSIA, that 
revision will become the new CPSC standard, unless the Commission 
determines that ASTM's revision does not improve the safety of the 
product. Thus, unless the Commission makes such a determination, the 
ASTM revision becomes CPSC's standard by operation of law. The 
Commission is allowing ASTM F1967-19 to become CPSC's new standard. The 
purpose of this direct final rule is merely to update the reference in 
the Code of Federal Regulations so that it reflects accurately the 
version of the standard that takes effect by statute. Public comment 
will not impact the substantive changes to the standard or the effect 
of the revised standard as a consumer product safety standard under 
section 104(b) of the CPSIA. Under these circumstances, notice and 
comment are not necessary. In Recommendation 95-4, the Administrative 
Conference of the United States (ACUS) endorsed direct final rulemaking 
as an appropriate procedure to expedite promulgating rules that are 
noncontroversial and that are not expected to generate significant 
adverse comment. See 60 FR 43108 (August 18, 1995). ACUS recommended 
that agencies use the direct final rule process when they act under the 
``unnecessary'' prong of the good cause exemption in 5 U.S.C. 
553(b)(B). Consistent with the ACUS recommendation, the Commission is 
publishing this rule as a direct final rule because we do not expect 
any significant adverse comments.
    Unless we receive a significant adverse comment within 30 days, the 
rule will become effective on December 22, 2019. In accordance with 
ACUS's recommendation, the Commission considers a significant adverse 
comment to be one where the commenter explains why the rule would be 
inappropriate, including an assertion challenging the rule's underlying 
premise or approach, or a claim that the rule would be ineffective or 
unacceptable without change.
    Should the Commission receive a significant adverse comment, the 
Commission would withdraw this direct final rule. Depending on the 
comments and other circumstances, the Commission may then incorporate 
the adverse comment into a subsequent direct final rule or publish a 
notice of proposed rulemaking, providing an opportunity for public 
comment.

H. Regulatory Flexibility Act

    The Regulatory Flexibility Act (RFA) generally requires that 
agencies review proposed and final rules for their potential economic 
impact on small entities, including small businesses, and prepare 
regulatory flexibility analyses. 5 U.S.C. 603 and 604. The RFA applies 
to any rule that is subject to notice and

[[Page 49439]]

comment procedures under section 553 of the APA. Id. As explained, the 
Commission has determined that notice and comment are not necessary for 
this direct final rule. Thus, the RFA does not apply. We also note the 
limited nature of this document, which updates the incorporation by 
reference to reflect the mandatory CPSC standard that takes effect 
under section 104 of the CPSIA.

I. Paperwork Reduction Act

    The standard for infant bath seats contains information collection 
requirements under the Paperwork Reduction Act of 1995 (44 U.S.C. 3501-
3520). The revisions made no changes to that section of the standard. 
Thus, the revisions will not have any effect on the information 
collection requirements related to the standard.

J. Environmental Considerations

    The Commission's regulations provide a categorical exclusion for 
the Commission's rules from any requirement to prepare an environmental 
assessment or an environmental impact statement because they ``have 
little or no potential for affecting the human environment.'' 16 CFR 
1021.5(c)(2). This rule falls within the categorical exclusion, so no 
environmental assessment or environmental impact statement is required.

K. Preemption

    Section 26(a) of the CPSA, 15 U.S.C. 2075(a), provides that where a 
consumer product safety standard is in effect and applies to a product, 
no state or political subdivision of a state may either establish or 
continue in effect a requirement dealing with the same risk of injury 
unless the state requirement is identical to the federal standard. 
Section 26(c) of the CPSA also provides that states or political 
subdivisions of states may apply to the CPSC for an exemption from this 
preemption under certain circumstances. Section 104(b) of the CPSIA 
refers to the rules to be issued under that section as ``consumer 
product safety rules,'' thus, implying that the preemptive effect of 
section 26(a) of the CPSA would apply. Therefore, a rule issued under 
section 104 of the CPSIA will invoke the preemptive effect of section 
26(a) of the CPSA when it becomes effective.

L. Effective Date

    Under the procedure set forth in section 104(b)(4)(B) of the CPSIA, 
when a voluntary standard organization revises a standard upon which a 
consumer product safety standard was based, the revision becomes the 
CPSC standard within 180 days of notification to the Commission, unless 
the Commission determines that the revision does not improve the safety 
of the product, or the Commission sets a later date in the Federal 
Register. The Commission has not set a different effective date. Thus, 
in accordance with this provision, this rule takes effect 180 days 
after we received notification from ASTM of revision to this standard. 
As discussed in the preceding section, this is a direct final rule. 
Unless we receive a significant adverse comment within 30 days, the 
rule will become effective on December 22, 2019.

List of Subjects in 16 CFR Part 1215

    Consumer protection, Imports, Incorporation by reference, Infants 
and children, Law enforcement, Safety, Toys.

    For the reasons stated above, the Commission amends Title 16 CFR 
chapter II as follows:

PART 1215--SAFETY STANDARD FOR INFANT BATH SEATS

0
 1. The authority citation for part 1215 continues to read as follows:

    Authority:  Sec. 104, Pub. L. 110-314, 122 Stat. 3016 (August 
14, 2008); Sec. 3, Pub. L. 112-28, 125 Stat. 273 (August 12, 2011).


0
 2. Revise Sec.  1215.2 to read as follows:


Sec.  1215.2   Requirements for infant bath seats.

    Each infant bath seat shall comply with all applicable provisions 
of ASTM F1967-19, Standard Consumer Safety Specification for Infant 
Bath Seats, approved May 1, 2019. The Director of the Federal Register 
approves the incorporation by reference listed in this section in 
accordance with 5 U.S.C. 552(a) and 1 CFR part 51. You may obtain a 
copy of this ASTM standard from ASTM International, 100 Barr Harbor 
Drive, PO Box C700, West Conshohocken, PA 19428-2959 USA; phone: 610-
832-9585; www.astm.org. You may inspect a copy at the Division of the 
Secretariat, U.S. Consumer Product Safety Commission, Room 820, 4330 
East West Highway, Bethesda, MD 20814, telephone 301-504-7923, or at 
the National Archives and Records Administration (NARA). For 
information on the availability of this material at NARA, email 
[email protected], or go to: www.archives.gov/federal-register/cfr/ibr-locations.html.

 Alberta E. Mills,
Secretary, U.S. Consumer Product Safety Commission.
[FR Doc. 2019-19965 Filed 9-19-19; 8:45 am]