NUCLEAR REGULATORY COMMISSION
[Docket Nos. 50-369 and 50-370; NRC-2016-0128]
Duke Energy Carolinas, LLC and North Carolina Electric Membership
Corporation; Acceptance Criteria for Emergency Core Cooling Systems,
McGuire Nuclear Station, Units 1 and 2, Catawba Nuclear Station, Units
1 and 2
AGENCY: Nuclear Regulatory Commission.
ACTION: Exemption; issuance.
-----------------------------------------------------------------------
SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) is issuing an
exemption in response to a license amendment request and exemption
request dated August 20, 2015, from Duke Energy Carolinas, LLC (Duke
Energy or the licensee) from portions of the regulations to support the
use of fuel that is clad in Optimized ZIRLO\TM\.
ADDRESSES: Please refer to Docket ID NRC-2016-0128 when contacting the
NRC about the availability of information regarding this document. You
may obtain publicly-available information related to this document
using any of the following methods:
Federal Rulemaking Web site: Go to http://www.regulations.gov and search for Docket ID NRC-2016-0128. Address
questions about NRC dockets to Carol Gallagher; telephone: 301-415-
3463; email: [email protected].
NRC's Agencywide Documents Access and Management System
(ADAMS): You may obtain publicly-available documents online in the
ADAMS Public Documents collection at http://www.nrc.gov/reading-rm/adams.html. To begin the search, select ``ADAMS Public Documents'' and
then select ``Begin Web-based ADAMS Search.'' For problems with ADAMS,
please contact the NRC's Public Document Room (PDR) reference staff at
1-800-397-4209, 301-415-4737, or by email to [email protected]. The
ADAMS accession number for each document referenced (if it is available
in ADAMS) is provided the first time that it is mentioned in this
document.
NRC's PDR: You may examine and purchase copies of public
documents at the NRC's PDR, Room O1-F21, One White Flint North, 11555
Rockville Pike, Rockville, Maryland 20852.
FOR FURTHER INFORMATION CONTACT: G. Edward Miller, Office of Nuclear
Reactor Regulation, U.S. Nuclear Regulatory Commission, Washington DC
20555-0001; telephone: 301-415-2481, email [email protected].
SUPPLEMENTARY INFORMATION:
I. Background
Duke Energy is the holder of Facility Operating License Nos. NPF-9,
NPF-17, NPF-35, and NPF-52, which authorize operation of the McGuire
Nuclear Station (MNS), Units 1 and 2, and Catawba Nuclear Station
(CNS), Units 1 and 2. The licenses provide, among other things, that
each facility is subject to all rules, regulations, and orders of the
NRC now or hereafter in effect.
The MNS and CNS units are pressurized-water reactor located in
Mecklenburg County, North Carolina, and York County, South Carolina,
respectively.
II. Request/Action
Pursuant to section 50.12 of title 10 of the Code of Federal
Regulations (10
[[Page 42757]]
CFR), ``Specific Exemptions,'' the licensee has, by letter dated August
20, 2015 (ADAMS Accession No. ML15295A016), requested an exemption from
10 CFR 50.46, ``Acceptance criteria for emergency core cooling systems
[ECCS] for light-water nuclear power reactors,'' and appendix K to 10
CFR part 50, ``ECCS Evaluation Models'' to allow the use of fuel rods
clad with Optimized ZIRLO\TM\. Section 50.46 requires that the
calculated cooling performance following postulated loss-of-coolant
accidents at reactors fueled with zircaloy or ZIRLO[supreg] cladding
conforms to the criteria set forth in paragraph (b) of that section. In
addition, appendix K to 10 CFR part 50, in part, requires that the
Baker-Just equation be used to predict the rates of energy release,
hydrogen concentration, and cladding oxidation from the metal/water
reaction. The Baker-Just equation assumes the use of zircaloy or
ZIRLO[supreg], materials that have different chemical compositions from
Optimized ZIRLO\TM\. As written, these regulations presume only the use
of zircaloy or ZIRLO[supreg] fuel rod cladding and do not contain
provisions for use of fuel rods with other cladding materials.
Therefore, an exemption from the requirements of 10 CFR 50.46 and part
50, appendix K, is needed to support the use of a different fuel rod
cladding material. Accordingly, the licensee requested an exemption
that would allow the use of Optimized ZIRLO\TM\ fuel rod cladding at
MNS and CNS.
III. Discussion
Pursuant to 10 CFR 50.12, the Commission may, upon application by
any interested person or upon its own initiative, grant exemptions from
the requirements of 10 CFR part 50, when the exemptions are authorized
by law, will not present an undue risk to public health or safety, and
are consistent with the common defense and security. However, Sec.
50.12(a)(2) states that the Commission will not consider granting an
exemption unless special circumstances are present as set forth in
Sec. 50.12(a)(2). Under 10 CFR 50.12(a)(2)(ii), special circumstances
are present when application of the regulation in the particular
circumstances would not serve, or is not necessary to achieve, the
underlying purpose of the rule.
Special Circumstances
Special circumstances, in accordance with 10 CFR 50.12(a)(2)(ii),
are present whenever application of the regulation in the particular
circumstances is not necessary to achieve the underlying purpose of the
rule. The underlying purpose of 10 CFR 50.46 and appendix K to 10 CFR
part 50 is to establish acceptance criteria for ECCS performance to
provide reassurance of safety in the event of a loss-of-coolant (LOCA)
accident. Although the wording of the regulations in 10 CFR 50.46 and
appendix K is not expressly applicable to Optimized ZIRLOTM,
the evaluations described in the following sections of this exemption
show that the purpose of the regulations are met by this exemption in
that, subject to certain conditions, the acceptance criteria are valid
for Optimized ZIRLO\TM\ fuel cladding material, Optimized ZIRLO\TM\
would maintain better post-quench ductility, and the Baker-Just
equation conservatively bounds LOCA scenario metal-water reaction rates
and is applicable to Optimized ZIRLO\TM\. Because the underlying
purposes of 10 CFR 50.46 and appendix K can be achieved through the
application of these requirements to the use of Optimized
ZIRLOTM fuel rod cladding material, the special
circumstances required by 10 CFR 50.12(a)(2)(ii) for the granting of an
exemption exist.
The Exemption Is Authorized by Law
This exemption would allow the use of fuel rods clad with Optimized
ZIRLO\TM\ in future core reload applications for MNS and CNS. Section
50.12 allows the NRC to grant exemptions from the requirements of 10
CFR part 50 provided that the exemptions are authorized by law. The NRC
staff determined that special circumstances exist to grant the proposed
exemption and that granting the exemption would not result in a
violation of the Atomic Energy Act of 1954, as amended. Therefore, the
exemption is authorized by law.
No Undue Risk to Public Health and Safety
The provisions of 10 CFR 50.46 establish acceptance criteria for
ECCS performance. Westinghouse topical reports WCAP-12610-P-A and
CENPD-404-P-A, Addendum 1-A, ``Optimized ZIRLO\TM\,'' dated July 2006,
contain the justification to use Optimized ZIRLOTM fuel rod
cladding material in addition to Zircaloy-4 and ZIRLO[supreg]. The
complete topical reports are not publicly available because they
contain proprietary information, however, a redacted version and the
NRC safety evaluation are available under ADAMS Accession No.
ML062080569. The NRC staff found that the Westinghouse topical reports
demonstrated the applicability of these ECCS acceptance criteria to
Optimized ZIRLO\TM\, subject to the compliance with the specific
conditions of approval established therein. The NRC staff reviewed the
August 20, 2015, application against these specific conditions and
found that the licensee was in compliance with all of the applicable
conditions. The NRC staff's review of these specific conditions for MNS
and CNS can be found under ADAMS Accession No. ML16105A326.
Ring compression tests performed by Westinghouse on Optimized
ZIRLOTM were reviewed and approved by the NRC staff in
topical report WCAP-14342-A & CENPD-404-NP-A, Addendum 1-A, and
demonstrate an acceptable retention of post-quench ductility up to the
10 CFR 50.46 limits of 2,200 degrees Fahrenheit and 17 percent
equivalent clad reacted. Furthermore, the NRC staff has concluded that
oxidation measurements provided by Westinghouse illustrate that oxide
thickness (and associated hydrogen pickup) for Optimized ZIRLO\TM\ at
any given burnup would be less than that for both zircaloy and
ZIRLOTM (ADAMS Package Accession No. ML073130555). Hence,
the NRC staff concludes that Optimized ZIRLOTM would be
expected to maintain acceptable post-quench ductility.
The provisions of 10 CFR part 50, appendix K, paragraph I.A.5,
``Metal-Water Reaction Rate,'' serve to ensure that cladding oxidation
and hydrogen generation are limited appropriately during a loss-of-
coolant accident (LOCA) and conservatively accounted for in the ECCS
evaluation model. That regulation requires that the Baker-Just equation
be used in the ECCS evaluation model to determine the rate of energy
release, cladding oxidation, and hydrogen generation. Since the use of
the Baker-Just equation presumes the use of zircaloy-clad fuel, strict
application of the rule would not permit use of the equation for
Optimized ZIRLOTM cladding for determining acceptable fuel
performance. As concluded in the NRC staff safety evaluation for the
associated topical report, Westinghouse demonstrated that the Baker-
Just model is conservative in all post-LOCA scenarios with respect to
the use of the Optimized ZIRLOTM as a fuel cladding
material.
The NRC-approved topical reports have demonstrated that predicted
chemical, thermal, and mechanical characteristics of the Optimized
ZIRLOTM alloy cladding are bounded by those approved for
ZIRLO[supreg] under anticipated operational occurrences and postulated
accidents. Reload cores are required to be operated in accordance with
the operating limits specified in the technical specifications and the
core operating limits report.
[[Page 42758]]
Based on the above, no new accident precursors are created by using
Optimized ZIRLOTM; thus, the probability of postulated
accidents is not increased. Also, based on the above, the consequences
of postulated accidents are not increased. Therefore, there is no undue
risk to public health and safety due to using Optimized ZIRLO\TM\.
Consistent With Common Defense and Security
The proposed exemption would allow the use of Optimized ZIRLO\TM\
fuel rod cladding material at MNS and CNS. This change to the plant
configuration is adequately controlled by TS requirements and is not
related to security issues. Because the common defense and security is
not impacted by this exemption, the exemption is consistent with the
common defense and security.
Environmental Considerations
The NRC staff determined that the exemption discussed herein meets
the eligibility criteria for the categorical exclusion set forth in 10
CFR 51.22(c)(9) because it is related to a requirement concerning the
installation or use of a facility component located within the
restricted area, as defined in 10 CFR part 20, and issuance of this
exemption involves: (i) No significant hazards consideration, (ii) no
significant change in the types or a significant increase in the
amounts of any effluents that may be released offsite, and (iii) no
significant increase in individual or cumulative occupational radiation
exposure. Therefore, in accordance with 10 CFR 51.22(b), no
environmental impact statement or environmental assessment need be
prepared in connection with the NRC's consideration of this exemption
request. The basis for the NRC staff's determination is discussed as
follows with an evaluation against each of the requirements in 10 CFR
51.22(c)(9)(i)-(iii).
Requirements in 10 CFR 51.22(c)(9)(i)
The NRC staff evaluated whether the exemption involves no
significant hazards consideration using the standards described in 10
CFR 50.92(c), as presented below:
1. Does the proposed exemption involve a significant increase in
the probability or consequences of an accident previously evaluated?
Response: No.
The proposed TS changes add flexibility in the selection of fuel
rod cladding materials for use at CNS and MNS. The proposed change of
adding a cladding material does not result in an increase to the
probability or consequences of an accident previously evaluated. TS
4.2.1 addresses the fuel assembly design, and currently specifies that,
``Each assembly shall consist of a matrix of either ZIRLO[supreg] or
Zircaloy fuel rods . . .'' The proposed change will add Optimized
ZIRLO\TM\ to the approved fuel rod cladding materials listed in this
TS. In addition, a reference to the Westinghouse VANTAGE+ fuel assembly
core reference report, WCAP-12610-P-A, and the topical report for
Optimized ZIRLO\TM\, WCAP-12610-P-A and CENPD-404-P-A, Addendum 1-A,
will be included in the listing of approved methods used to determine
the core operating limits for CNS and MNS given in TS 5.6.5.b.
Westinghouse topical report WCAP-12610-P-A and CENPD-404-P-A, Addendum
1-A, Optimized ZIRLO\TM\, provides the details and results of material
testing of Optimized ZIRLO\TM\ compared to standard ZIRLO[supreg], as
well as the material properties to be used in various models and
methodologies when analyzing Optimized ZIRLO\TM\. As the nuclear
industry pursues longer operating cycles with increased fuel discharge
burnup and fuel duty, the corrosion performance requirements for the
nuclear fuel cladding become more demanding. Optimized ZIRLO\TM\ was
developed to meet these industry needs by providing a reduced corrosion
rate while maintaining the composition and physical properties, such as
mechanical strength, similar to standard ZIRLO[supreg]. Fuel rod
internal pressure has also become more limiting due to changes such as
increased fuel duty and use of integral fuel burnable absorbers.
Reducing the associated corrosion buildup by using Optimized ZIRLO\TM\
in turn reduces temperature feedback effects, providing additional
margin to the fuel rod internal pressure design criterion. Fuel with
Optimized ZIRLO\TM\ cladding will continue to satisfy the pertinent
design basis operating limits, so cladding integrity is maintained.
There are no changes that will adversely affect the ability of existing
components and systems to mitigate the consequences of any accident.
Therefore, addition of Optimized ZIRLO\TM\ to the allowable cladding
materials for CNS and MNS does not result in an increase in the
probability or consequences of an accident previously evaluated.
The NRC has previously approved use of Optimized ZIRLO\TM\ fuel
cladding material in Westinghouse fueled reactors provided that
licensees ensure compliance with the Conditions and Limitations set
forth in the NRC Safety Evaluation for the topical report. Confirmation
that these Conditions are satisfied is performed as part of the normal
core reload process.
Therefore, the proposed change does not involve a significant
increase in the probability or consequences of an accident previously
evaluated.
2. Does the proposed exemption create the possibility of a new or
different kind of accident from any accident previously evaluated?
Response: No.
The proposed TS changes add flexibility in the selection of fuel
rod cladding materials for use at CNS and MNS. Optimized ZIRLO\TM\ was
developed to provide a reduced cladding corrosion rate while
maintaining the benefits of mechanical strength and resistance to
accelerated corrosion from potential abnormal chemistry conditions. The
fuel rod design bases are established to satisfy the general and
specific safety criteria addressed in the CNS and MNS UFSAR [Updated
Final Safety Analysis Report], Chapter 15 (Accident Analyses). The fuel
rods are designed to prevent excessive fuel temperatures, excessive
fuel rod internal gas pressures due to fission gas releases, and
excessive cladding stresses and strains. Westinghouse topical report
WCAP-12610-P-A and CENPD-404-P-A, Addendum 1-A, Optimized ZIRLO\TM\,
provides the details and results of material testing of Optimized
ZIRLO\TM\ compared to standard ZIRLO[supreg], as well as the material
properties to be used in various models and methodologies when
analyzing Optimized ZIRLO\TM\. The original fuel design basis
requirements have been maintained. No new single failure mechanisms
will be created, and there are no alterations to plant equipment or
procedures that would introduce any new or unique operational modes or
accident precursors. Therefore, addition of another approved cladding
material of similar composition and properties as the current approved
cladding materials to the CNS and MNS TS does not create the
possibility of a new or different kind of accident or malfunction from
those previously evaluated within the UFSAR.
3. Does the proposed exemption involve a significant reduction in a
margin of safety?
Response: No.
The proposed change will not involve a significant reduction in the
margin of safety because it has been demonstrated that the material
properties of the Optimized ZIRLO\TM\ are not significantly different
from those of standard ZIRLO[supreg]. Optimized ZIRLO\TM\ is expected
to perform similarly to
[[Page 42759]]
standard ZIRLO[supreg] for all normal operating and accident scenarios,
including both loss of coolant accident (LOCA) and non-LOCA scenarios.
For LOCA scenarios, where the slight difference in Optimized ZIRLO\TM\
material properties relative to standard ZIRLO[supreg] could have some
impact on the overall accident scenario, plant-specific LOCA analyses
using Optimized ZIRLO\TM\ properties demonstrates that the acceptance
criteria of 10 CFR 50.46 has been satisfied, therefore, the proposed
change does not involve a significant reduction in a margin of safety.
Based on the above, the NRC staff concludes that the proposed
exemption involves no significant hazards consideration. Accordingly,
the requirements of 10 CFR 51.22(c)(9)(i) are met.
Requirements in 10 CFR 51.22(c)(9)(ii)
The proposed exemption would allow the use of Optimized ZIRLO\TM\
fuel rod cladding material in the reactors. Optimized ZIRLO\TM\ has
essentially the same material properties and performance
characteristics as the currently licensed ZIRLO[supreg] cladding. Thus,
the use of Optimized ZIRLO\TM\ fuel rod cladding material will not
significantly change the types of effluents that may be released
offsite, or significantly increase the amount of effluents that may be
released offsite. Therefore, the requirements of 10 CFR 51.22(c)(9)(ii)
are met.
Requirements in 10 CFR 51.22(c)(9)(iii)
The proposed exemption would allow the use of Optimized ZIRLO\TM\
fuel rod cladding material in the reactors. Optimized ZIRLO\TM\ has
essentially the same material properties and performance
characteristics as the currently licensed ZIRLO[supreg] cladding. Thus,
the use of Optimized ZIRLO\TM\ fuel rod cladding material will not
significantly increase individual occupational radiation exposure, or
significantly increase cumulative occupational radiation exposure.
Therefore, the requirements of 10 CFR 51.22(c)(9)(iii) are met.
IV. Conclusions
Accordingly, the Commission has determined that pursuant to 10 CFR
50.12(a), the exemption is authorized by law, will not present an undue
risk to the public health and safety, is consistent with the common
defense and security, and that special circumstances are present to
warrant issuance of the exemption. Therefore, the Commission hereby
grants Duke Energy an exemption from the requirements of 10 CFR 50.46
and Appendix K, paragraph I.A.5 to 10 CFR part 50, to allow the
application of these criteria to, and the use of, Optimized ZIRLO\TM\
fuel rod cladding material at MNS and CNS.
This exemption is effective upon issuance.
Dated at Rockville, Maryland, this 21st day of June 2016.
For the Nuclear Regulatory Commission.
Anne T. Boland,
Director, Division of Operating Reactor Licensing, Office of Nuclear
Reactor Regulation.
[FR Doc. 2016-15548 Filed 6-29-16; 8:45 am]
BILLING CODE 7590-01-P