CONSUMER PRODUCT SAFETY COMMISSION
16 CFR Part 1211
Safety Standard for Automatic Residential Garage Door Operators
AGENCY: Consumer Product Safety Commission.
ACTION: Final rule.
-----------------------------------------------------------------------
SUMMARY: The Consumer Product Safety Commission is amending 16 CFR part
1211, Safety Standard for Automatic Residential Garage Door Operators,
to reflect changes made by Underwriters Laboratories, Inc. in its
standard UL 325.
DATES: This rule is effective on February 21, 2008, except for Sec.
1211.14(b)(2) which is effective September 27, 2007.
FOR FURTHER INFORMATION CONTACT: Renae Rauchschwalbe, Office of
Compliance and Field Operations, Consumer Product Safety Commission,
4330 East-West Highway, Bethesda, Maryland, 20814-4408, telephone 301-
504-7664 or e-mail: [email protected].
SUPPLEMENTARY INFORMATION: The Commission is amending its garage door
operator standard, 16 CFR part 1211, to incorporate changes made to
Underwriter Laboratories, Inc. (``UL'') standard UL 325, third edition,
``Door, Drapery, Louver and Window Operators and Systems.'' In 1991,
Congress mandated the entrapment protection provisions of the UL 325
standard as a consumer product safety standard. Sec 203 of Public Law
101-608. Congress also required the Commission to incorporate into part
1211 any revisions that UL proposed to the entrapment protection
requirements of UL 325, unless the Commission notified UL that the
revision does not carry out the purposes of Public Law 101-608.
Recently, UL revised some provisions of UL 325 to address the
hazard of children becoming entrapped if a child becomes stuck under a
partially open door and the door moves down when a bystander presses
the wall control button. The Commission determined that the entrapment
related revisions incorporated into the UL standard do carry out the
purposes of Public Law 101-608. On January 18, 2007, the Commission
issued a notice of proposed rulemaking (``NPR'') to revise part 1211 to
reflect the changes UL made to UL 325. 72 FR 2217. The Commission
received no comments on the proposal and is now making the revisions
final.
UL set an effective date of February 21, 2008 for the changes to
the entrapment protection requirements in the UL standard. The
Commission is specifying the same effective date for these provisions
in the CPSC standard.
UL also added to its standard a requirement that the statement
``Never go under a stopped partially open door'' be added to garage
door operator instruction manuals. The Commission is making this change
in the CPSC standard as well. UL set an effective date of September 14,
2004 for this provision in UL 325. The instruction manual provision in
the CPSC standard would become effective when published as a final rule
in the Federal Register.
[[Page 54817]]
Pursuant to section 605(b) of the Regulatory Flexibility Act, 5
U.S.C. 605(b), in the NPR the Commission certified that this rule will
not have a significant impact on a substantial number of small
entities. The Commission also certified in the NPR that this rule will
have no environmental impact.
Public Law 101-608 contains a preemption provision. It states:
``those provisions of laws of States or political subdivisions which
relate to the labeling of automatic residential garage door openers and
those provisions which do not provide at least the equivalent degree of
protection from the risk of injury associated with automatic
residential garage door openers as the consumer product safety rule''
are subject to preemption under 15 U.S.C. 2075. Public Law 101-608,
section 203(f).
List of Subjects in 16 CFR Part 1211
Consumer protection, Imports, Labeling, Reporting and recordkeeping
requirements.
0
Accordingly, 16 CFR part 1211 is amended as follows:
PART 1211--SAFETY STANDARDS FOR AUTOMATIC RESIDENTIAL GARAGE DOOR
OPERATORS
0
1. The authority citation for part 1211 continues to read as follows:
Authority: Sec. 203 of Pub. L. 101-608, 104 Stat. 3110; 15
U.S.C. 2063 and 2065.
0
2. Section 1211.7 is amended by revising paragraphs (a), (b), (f) and
(g) to read as follows:
Sec. 1211.7 Inherent entrapment protection requirements.
(a)(1) Other than for the first 1 foot (305mm) of door travel from
the full upmost position both with and without any external entrapment
protection device functional, the operator of a downward moving
residential garage door shall initiate reversal of the door within 2
seconds of contact with the obstruction as specified in paragraph (b)
of this section. After reversing the door, the operator shall return
the door to, and stop at, the full upmost position. Compliance shall be
determined in accordance with paragraphs (b) through (i) of this
section.
(2) The door operator is not required to return the door to, and
stop the door at, the full upmost position when the operator senses a
second obstruction during the upward travel.
(3) The door operator is not required to return the door to, and
stop the door at, the full upmost position when a control is actuated
to stop the door during the upward travel--but the door can not be
moved downward until the operator reverses the door a minimum of 2
inches (50.8 mm).
(b)(1) A solid object is to be placed on the floor of the test
installation and at various heights under the edge of the door and
located in line with the driving point of the operator. When tested on
the floor, the object shall be 1 inch (25.4 mm) high. In the test
installation, the bottom edge of the door under the driving force of
the operator is to be against the floor when the door is fully closed.
(2) For operators other than those attached to the door, a solid
object is not required to be located in line with the driving point of
the operator. The solid object is to be located at points at the
center, and within 1 foot of each end of the door.
(3) To test operators for compliance with requirements in
paragraphs (a)(3), (f)(3), and (g)(3) of this section, Sec.
1211.10(a)(6)(iii), and Sec. 1211.13(c), a solid rectangular object
measuring 4 inches (102 mm) high by 6 inches (152 mm) wide by a minimum
of 6 inches (152 mm)long is to be placed on the floor of the test
installation to provide a 4-inch (102 mm) high obstruction when
operated from a partially open position.
* * * * *
(f)(1) An operator, using an inherent entrapment protection system
that monitors the actual position of the door, shall initiate reversal
of the door and shall return the door to, and stop the door at, the
full upmost position in the event the inherent door operating
``profile'' of the door differs from the originally set parameters. The
entrapment protection system shall monitor the position of the door at
increments not greater than 1 inch (25.4 mm).
(2) The door operator is not required to return the door to, and
stop the door at, the full upmost position when an inherent entrapment
circuit senses an obstruction during the upward travel.
(3) The door operator is not required to return the door to, and
stop the door at, the full upmost position when a control is actuated
to stop the door during the upward travel--but the door can not be
moved downward until the operator reverses the door a minimum of 2
inches (50.8 mm).
(g)(1) An operator, using an inherent entrapment protection system
that does not monitor the actual position of the door, shall initiate
reversal of the door and shall return the door to and stop the door at
the full upmost position, when the lower limiting device is not
actuated in 30 seconds or less following the initiation of the close
cycle.
(2) The door operator is not required to return the door to, and
stop the door at, the full upmost position when an inherent entrapment
circuit senses an obstruction during the upward travel. When the door
is stopped manually during its descent, the 30 seconds shall be
measured from the resumption of the close cycle.
(3) The door operator is not required to return the door to, and
stop the door at, the full upmost position when a control is actuated
to stop the door during the upward travel--but the door can not be
moved downward until the operator reverses the door a minimum of 2
inches (50.8 mm). When the door is stopped manually during its descent,
the 30 seconds shall be measured from the resumption of the close
cycle.
0
3. Section 1211.10 is amended by revising paragraph (a)(1) and adding a
new paragraph (a)(6) to read as follows:
Sec. 1211.10 Requirements for all entrapment protection devices.
(a) General requirements. (1) An external entrapment protection
device shall perform its intended function when tested in accordance
with paragraphs (a)(2) through (4) and (6) of this section.
* * * * *
(6)(i) An operator using an external entrapment protection device,
upon detecting a fault or an obstruction in the path of a downward
moving door, shall initiate reversal and shall return the door to, and
stop the door at, the full upmost position.
(ii) The door operator is not required to return the door to, and
stop the door at, the full upmost position when an inherent entrapment
circuit senses an obstruction during the upward travel.
(iii) The door operator is not required to return the door to, and
stop the door at, the full upmost position when a control is actuated
to stop the door during the upward travel--but the door can not be
moved downward until the operator has reversed the door a minimum of 2
inches (50.8 mm).
0
4. Section 1211.13 is amended by adding a new paragraph (c) to read as
follows:
Sec. 1211.13 Inherent force activated secondary door sensors.
(a) * * *
(b) * * *
(c) Obstruction test. For a door traveling in the downward
direction, when an inherent secondary entrapment protection device
senses an obstruction and initiates a reversal, a control activation
shall not move the door
[[Page 54818]]
downward until the operator reverses the door a minimum of 2 inches
(50.8 mm). The test is to be performed as described in Sec.
1211.7(b)(3).
Sec. 1211.14 [Amended]
0
5. Section 1211.14 is amended by revising paragraph (b)(2) to read as
follows:
(a) * * *
(b) Specific required instructions.
(1) * * *
(2) The User Instructions shall include the following instructions:
Important Safety Instructions
Warning--To reduce the risk of severe injury or death:
1. Read and follow all instructions.
2. Never let children operate, or play with door controls. Keep the
remote control away from children.
3. Always keep the moving door in sight and away from people and
objects until it is completely closed. No one should cross the path of
the moving door.
4. NEVER GO UNDER A STOPPED PARTIALLY OPEN DOOR.
5. Test door opener monthly. The garage door MUST reverse on
contact with a 1\1/2\ inch object (or a 2 by 4 board laid flat) on the
floor. After adjusting either the force or the limit of travel, retest
the door opener. Failure to adjust the opener properly may cause severe
injury or death.
6. For products requiring an emergency release, if possible, use
the emergency release only when the door is closed. Use caution when
using this release with the door open. Weak or broken springs may allow
the door to fall rapidly, causing injury or death.
7. Keep garage door properly balanced. See owner's manual. An
improperly balanced door could cause severe injury or death. Have a
qualified service person make repairs to cables, spring assemblies and
other hardware.
8. Save these Instructions.