NUCLEAR REGULATORY COMMISSION
[Docket Nos. 50-424 AND 50-425]
Southern Nuclear Operating Company, Inc.; Notice of Consideration
of Issuance of Amendment to Facility Operating License, Proposed No
Significant Hazards; Consideration Determination, and Opportunity for a
Hearing
The U.S. Nuclear Regulatory Commission (the Commission) is
considering issuance of amendments to Facility Operating License Nos.
NPF-68 and NPF-81 issued Southern Nuclear Operating Company, Inc.
(SNC), for operation of the Vogtle Electric Generating Plant (VEGP),
Units 1 and 2, located in Burke County, Georgia.
The proposed amendment would revise, on a one-time basis, Technical
Specification (TS) 5.5.9, ``Steam Generator (SG) Tube Surveillance
Program,'' to incorporate changes in the SG inspection scope for VEGP,
Unit 2 during Refueling Outage 11 and the subsequent operating cycle.
The proposed changes are applicable to Unit 2 only for inspections
during Refueling Outage 11 and for the subsequent operating cycle. The
proposed changes modify the inspection requirements for portions of SG
tubes within the hot leg tubesheet region of the SGs. The license for
VEGP, Unit 1 is affected only due to the fact that Units 1 and 2 use
common TSs.
Before issuance of the proposed license amendment, the Commission
will have made findings required by the Atomic Energy Act of 1954, as
amended (the Act), and the Commission's regulations.
The Commission has made a proposed determination that the amendment
request involves no significant hazards consideration. Under the
Commission's regulations in Title 10 of the Code of Federal Regulations
(10 CFR) Section 50.92, this means that operation of the facility in
accordance with the proposed amendment would not (1) involve a
significant increase in the probability or consequences of an accident
previously evaluated; or (2) create the possibility of a new or
different kind of accident from any accident previously evaluated; or
(3) involve a significant reduction in a margin of safety. As required
by 10 CFR 50.91(a), the licensee has provided its analysis of the issue
of no significant hazards consideration, which is presented below:
SNC has evaluated whether or not a significant hazards
consideration is involved with the proposed changes by focusing on
the three standards set forth in 10 CFR 50.92, ``Issuance of
Amendment,'' as discussed below:
1. Does the proposed license amendment involve a significant
increase in the probability or consequences of an accident
previously evaluated?
No. The previously analyzed accidents are initiated by the
failure of plant structures, systems, or components. The proposed
changes that alter the SG inspection criteria do not have a
detrimental impact on the integrity of any plant structure, system,
or component that initiates an analyzed event. The proposed changes
will not alter the operation of, or otherwise increase the failure
probability of any plant equipment that initiates an analyzed
accident. Therefore, the proposed change does not involve a
significant increase in the probability of an accident previously
evaluated.
Of the applicable accidents previously evaluated, the limiting
transients with consideration to the proposed changes to the SG tube
inspection criteria, are the SG tube rupture (SGTR) event and the
steam line break (SLB) accident.
During the SGTR event, the required structural integrity margins
of the SG tubes will be maintained by the presence of the SG
tubesheet. SG tubes are hydraulically expanded in the tubesheet
area. Tube rupture in tubes with cracks in the tubesheet is
precluded by the constraint provided by the tubesheet. This
constraint results from the hydraulic expansion process, thermal
expansion mismatch between the tube and tubesheet and from the
differential pressure between the primary and secondary side. Based
on this design, the structural margins against burst, discussed in
Regulatory Guide (RG) 1.121, ``Bases for Plugging Degraded PWR
[Pressurized-Water Reactor] SG Tubes,''
[[Page 48986]]
are maintained for both normal and postulated accident conditions.
The proposed changes do not affect other systems, structures,
components or operational features. Therefore, the proposed changes
result in no significant increase in the probability of the
occurrence of a SGTR accident. At normal operating pressures,
leakage from primary water stress corrosion cracking (PWSCC) below
the proposed limited inspection depth is limited by both the tube-
to-tubesheet crevice and the limited crack opening permitted by the
tubesheet constraint. Consequently, negligible normal operating
leakage is expected from cracks within the tubesheet region. The
consequences of an SGTR event are affected by the primary-to-
secondary leakage flow during the event.
Primary-to-secondary leakage flow through a postulated broken
tube is not affected by the proposed change since the tubesheet
enhances the tube integrity in the region of the hydraulic expansion
by precluding tube deformation beyond its initial hydraulically
expanded outside diameter.
The probability of a SLB is unaffected by the potential failure
of a SG tube as this failure is not an initiator for a SLB.
The consequences of a SLB are also not significantly affected by
the proposed changes. During a SLB accident, the reduction in
pressure above the tubesheet on the shell side of the SG creates an
axially uniformly distributed load on the tubesheet due to the
reactor coolant system pressure on the underside of the tubesheet.
The resulting bending action constrains the tubes in the tubesheet
thereby restricting primary-to-secondary leakage below the midplane.
Primary-to-secondary leakage from tube degradation in the
tubesheet area during the limiting accident (i.e., SLB) is limited
by flow restrictions resulting from the crack and tube-to-tubesheet
contact pressures that provide a restricted leakage path above the
indications and also limit the degree of potential crack face
opening as compared to free span indications. The primary-to-
secondary leak rate during postulated SLB accident conditions would
be expected to be less than that during normal operation for
indications near the bottom of the tubesheet (i.e., including
indications in the tube end welds). This conclusion is based on the
observation that while the driving pressure causing leakage
increases by approximately a factor of two, the flow resistance
associated with an increase in the tube-to-tubesheet contact
pressure, during a SLB, increases by up to approximately a factor of
three. While such a leakage decrease is logically expected, the
postulated accident leak rate could be conservatively bounded by
twice the normal operating leak rate if the increase in contact
pressure is ignored. Since normal operating leakage is
administratively limited (by NEI [Nuclear Energy Institute] 97-06)
to less than 0.10 gpm (150 gpd) in the Vogtle Unit 2 steam
generators, the attendant accident condition leak rate, assuming all
leakage to be from lower tubesheet indications, would be bounded by
0.20 gpm, which is less than the accident analysis assumption of
0.35 gpm included in Section 15.1.5 of the Vogtle Unit 2 UFSAR.
Hence it is reasonable to omit any consideration of inspection of
the tube, tube end weld, bulges/overexpansions or other anomalies
below 17 inches from the top of the hot leg tubesheet. Therefore,
the consequences of a SLB accident remain unaffected.
Based on the above discussion, the proposed changes do not
involve an increase in the consequences of an accident previously
evaluated.
2. Does the proposed license amendment create the possibility of
a new or different kind of accident from any accident previously
evaluated?
No. The proposed changes do not involve the use or installation
of new equipment and the currently installed equipment will not be
operated in a new or different manner. No new or different system
interactions are created and no new processes are introduced. The
proposed changes will not introduce any new failure mechanisms,
malfunctions, or accident initiators not already considered in the
design and licensing bases.
Based on this evaluation, the proposed change does not create
the possibility of a new or different kind of accident from any
accident previously evaluated.
3. Does the proposed amendment involve a significant reduction
in a margin of safety?
No. The proposed changes maintain the required structural
margins of the SG tubes for both normal and accident conditions.
Nuclear Energy Institute (NEI) 97-06, ``Steam Generator Program
Guidelines,'' Revision 1 and Regulatory Guide (RG) 1.121, ``Bases
for Plugging Degraded PWR Steam Generator Tubes,'' are used as the
bases in the development of the limited hot leg tubesheet inspection
depth methodology for determining that SG tube integrity
considerations are maintained within acceptable limits. RG 1.121
describes a method acceptable to the NRC for meeting General Design
Criteria (GDC) 14, ``Reactor coolant pressure boundary,'' GDC 15,
``Reactor coolant system design,'' GDC 31, ``Fracture prevention of
reactor coolant pressure boundary,'' and GDC 32, ``Inspection of
reactor coolant pressure boundary,'' by reducing the probability and
consequences of a SGTR. RG 1.121 concludes that by determining the
limiting safe conditions for tube wall degradation the probability
and consequences of a SGTR are reduced. This RG uses safety factors
on loads for tube burst that are consistent with the requirements of
Section III of the American Society of Mechanical Engineers (ASME)
Code.
Application of the limited hot leg tubesheet inspection depth
criteria will preclude unacceptable primary-to-secondary leakage
during all plant conditions. The methodology for determining leakage
provides for large margins between calculated and actual leakage
values in the proposed limited hot leg tubesheet inspection depth
criteria.
Therefore, the proposed changes do not involve a significant
hazards consideration under the criteria set forth in 10 CFR
50.92(c).
The NRC staff has reviewed the licensee's analysis and, based on
this review, it appears that the three standards of 10 CFR 50.92(c) are
satisfied. Therefore, the NRC staff proposes to determine that the
amendment request involves no significant hazards consideration.
The Commission is seeking public comments on this proposed
determination. Any comments received within 30 days after the date of
publication of this notice will be considered in making any final
determination.
Normally, the Commission will not issue the amendment until the
expiration of 60 days after the date of publication of this notice. The
Commission may issue the license amendment before expiration of the 60-
day period provided that its final determination is that the amendment
involves no significant hazards consideration. In addition, the
Commission may issue the amendment prior to the expiration of the 30-
day comment period should circumstances change during the 30-day
comment period such that failure to act in a timely way would result,
for example in derating or shutdown of the facility. Should the
Commission take action prior to the expiration of either the comment
period or the notice period, it will publish in the Federal Register a
notice of issuance. Should the Commission make a final No Significant
Hazards Consideration Determination, any hearing will take place after
issuance. The Commission expects that the need to take this action will
occur very infrequently.
Written comments may be submitted by mail to the Chief, Rules and
Directives Branch, Division of Administrative Services, Office of
Administration, U.S. Nuclear Regulatory Commission, Washington, DC
20555-0001, and should cite the publication date and page number of
this Federal Register notice. Written comments may also be delivered to
Room 6D59, Two White Flint North, 11545 Rockville Pike, Rockville,
Maryland, from 7:30 a.m. to 4:15 p.m. Federal workdays. Documents may
be examined, and/or copied for a fee, at the NRC's Public Document Room
(PDR), located at One White Flint North, Public File Area O1 F21, 11555
Rockville Pike (first floor), Rockville, Maryland.
The filing of requests for hearing and petitions for leave to
intervene is discussed below.
Within 60 days after the date of publication of this notice, the
licensee may file a request for a hearing with respect to issuance of
the amendment to the subject facility operating license and any person
whose interest may be affected by this proceeding and who
[[Page 48987]]
wishes to participate as a party in the proceeding must file a written
request for a hearing and a petition for leave to intervene. Requests
for a hearing and a petition for leave to intervene shall be filed in
accordance with the Commission's ``Rules of Practice for Domestic
Licensing Proceedings'' in 10 CFR Part 2. Interested persons should
consult a current copy of 10 CFR 2.309, which is available at the
Commission's PDR, located at One White Flint North, Public File Area
O1F21, 11555 Rockville Pike (first floor), Rockville, Maryland.
Publicly available records will be accessible from the Agencywide
Documents Access and Management System's (ADAMS) Public Electronic
Reading Room on the Internet at the NRC Web site, http://www.nrc.gov/reading-rm/doc-collections/cfr/. If a request for a hearing or petition
for leave to intervene is filed by the above date, the Commission or a
presiding officer designated by the Commission or by the Chief
Administrative Judge of the Atomic Safety and Licensing Board Panel,
will rule on the request and/or petition; and the Secretary or the
Chief Administrative Judge of the Atomic Safety and Licensing Board
will issue a notice of a hearing or an appropriate order.
As required by 10 CFR 2.309, a petition for leave to intervene
shall set forth with particularity the interest of the petitioner in
the proceeding, and how that interest may be affected by the results of
the proceeding. The petition should specifically explain the reasons
why intervention should be permitted with particular reference to the
following general requirements: (1) The name, address and telephone
number of the requestor or petitioner; (2) the nature of the
requestor's/petitioner's right under the Act to be made a party to the
proceeding; (3) the nature and extent of the requestor's/petitioner's
property, financial, or other interest in the proceeding; and (4) the
possible effect of any decision or order which may be entered in the
proceeding on the requestor's/petitioner's interest. The petition must
also identify the specific contentions which the petitioner/requestor
seeks to have litigated at the proceeding.
Each contention must consist of a specific statement of the issue
of law or fact to be raised or controverted. In addition, the
petitioner/requestor shall provide a brief explanation of the bases for
the contention and a concise statement of the alleged facts or expert
opinion which support the contention on which the petitioner intends to
rely in proving the contention at the hearing. The petitioner/requestor
must also provide references to those specific sources and documents of
which the petitioner is aware and on which the petitioner intends to
rely to establish those facts or expert opinion. The petition must
include sufficient information to show that a genuine dispute exists
with the applicant on a material issue of law or fact. Contentions
shall be limited to matters within the scope of the amendment under
consideration. The contention must be one which, if proven, would
entitle the petitioner to relief. A petitioner/requestor who fails to
satisfy these requirements with respect to at least one contention will
not be permitted to participate as a party.
Those permitted to intervene become parties to the proceeding,
subject to any limitations in the order granting leave to intervene,
and have the opportunity to participate fully in the conduct of the
hearing.
If a hearing is requested, the Commission will make a final
determination on the issue of no significant hazards consideration. The
final determination will serve to decide when the hearing is held. If
the final determination is that the amendment request involves no
significant hazards consideration, the Commission may issue the
amendment and make it immediately effective, notwithstanding the
request for a hearing. Any hearing held would take place after issuance
of the amendment. If the final determination is that the amendment
request involves a significant hazards consideration, any hearing held
would take place before the issuance of any amendment.
Nontimely requests and/or petitions and contentions will not be
entertained absent a determination by the Commission or the presiding
officer of the Atomic Safety and Licensing Board that the petition,
request and/or the contentions should be granted based on a balancing
of the factors specified in 10 CFR 2.309(c)(1)(I)-(viii).
A request for a hearing or a petition for leave to intervene must
be filed by: (1) First class mail addressed to the Office of the
Secretary of the Commission, U.S. Nuclear Regulatory Commission,
Washington, DC 20555-0001, Attention: Rulemaking and Adjudications
Staff; (2) courier, express mail, and expedited delivery services:
Office of the Secretary, Sixteenth Floor, One White Flint North, 11555
Rockville Pike, Rockville, Maryland, 20852, Attention: Rulemaking and
Adjudications Staff; (3) E-mail addressed to the Office of the
Secretary, U.S. Nuclear Regulatory Commission, [email protected];
or (4) facsimile transmission addressed to the Office of the Secretary,
U.S. Nuclear Regulatory Commission, Washington, DC, Attention:
Rulemakings and Adjudications Staff at (301) 415-1101, verification
number is (301) 415-1966. A copy of the request for hearing and
petition for leave to intervene should also be sent to the Office of
the General Counsel, U.S. Nuclear Regulatory Commission, Washington, DC
20555-0001, and it is requested that copies be transmitted either by
means of facsimile transmission to 301-415-3725 or by e-mail to
[email protected]. A copy of the request for hearing and petition
for leave to intervene should also be sent to Arthur H. Domby, Esquire,
Troutman Sanders, NationsBank Plaza, 600 Peachtree Street, NE., Suite
5200, Atlanta, GA 30308-2216, the attorney for the licensee.
For further details with respect to this action, see the
application for amendment dated August 12, 2005, which is available for
public inspection at the Commission's PDR, located at One White Flint
North, File Public Area O1 F21, 11555 Rockville Pike (first floor),
Rockville, Maryland. Publicly available records will be accessible from
the Agencywide Documents Access and Management System's (ADAMS) Public
Electronic Reading Room on the Internet at the NRC Web site, http://www.nrc.gov/reading-rm/adams.html. Persons who do not have access to
ADAMS or who encounter problems in accessing the documents located in
ADAMS, should contact the NRC PDR Reference staff by telephone at 1-
800-397-4209, 301-415-4737, or by e-mail to [email protected].
Dated at Rockville, Maryland, this 16th day of August 2005.
For the Nuclear Regulatory Commission.
Christopher Gratton,
Sr. Project Manager, Section 1, Project Directorate II, Division of
Licensing Project Management, Office of Nuclear Reactor Regulation.
[FR Doc. E5-4554 Filed 8-19-05; 8:45 am]