[Federal Register Volume 67, Number 192 (Thursday, October 3, 2002)]
[Notices]
[Pages 62091-62094]
From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
[FR Doc No: 02-25185]
=======================================================================
-----------------------------------------------------------------------
DEPARTMENT OF TRANSPORTATION
National Highway Traffic Safety Administration
[Docket No. NHTSA-02-13409]
Highway Safety Programs; Model Specifications for Devices To
Measure Breath Alcohol
AGENCY: National Highway Traffic Safety Administration, DOT.
ACTION: Notice.
-----------------------------------------------------------------------
SUMMARY: This notice amends the Conforming Products List for
instruments that conform to the Model Specifications for Evidential
Breath Testing Devices (58 FR 48705).
EFFECTIVE DATE: October 3, 2002.
FOR FURTHER INFORMATION CONTACT: Dr. James F. Frank, Research and
Technology Office, Behavioral Research Division (NTI-131), National
Highway Traffic Safety Administration, 400 Seventh Street, SW.,
Washington, DC 20590; Telephone: (202) 366-5593.
SUPPLEMENTARY INFORMATION: On November 5, 1973, the National Highway
Traffic Safety Administration (NHTSA) published the Standards for
Devices to Measure Breath Alcohol (38 FR 30459). A Qualified Products
List of Evidential Breath Measurement Devices comprised of instruments
that met this standard was first issued on November 21, 1974 (39 FR
41399).
On December 14, 1984 (49 FR 48854), NHTSA converted this standard
to Model Specifications for Evidential Breath Testing Devices, and
published a Conforming Products List (CPL) of instruments that were
found to conform to the Model Specifications as Appendix D to that
notice (49 FR 48864).
On September 17, 1993, NHTSA published a notice (58 FR 48705) to
amend the Model Specifications. The notice changed the alcohol
concentration levels at which instruments are evaluated, from 0.000,
0.050, 0.101, and 0.151 BAC, to 0.000, 0.020, 0.040, 0.080, and 0.160
BAC; added a test for the presence of acetone; and expanded the
definition of alcohol to include other low molecular weight alcohols
including methyl or isopropyl. On July 21, 2000, the most recent
amendment to the Conforming Products List (CPL) was published (65 FR
45419), identifying those instruments found to conform with the Model
Specifications.
Since the last publication of the CPL, seven (7) instruments have
been evaluated and found to meet the model specifications, as amended
on September 17, 1993, for mobile and non-mobile use. In alphabetical
order by company, they are: (1) Alert J4X.ec manufactured by Alcohol
Countermeasure Systems, Inc. of Mississauga, Ontario, Canada. This is a
hand held device that uses a fuel cell sensor and is powered by an
internal battery. (2) Intoxilyzer 8000 manufactured by CMI, Inc. of
Owensboro, KY. This is a non-dispersive infrared device which uses the
3.4 micron and the 9 micron band for measurement of alcohol. It is
powered by 120 volts AC power or by 12 volts DC power from a car
battery. (3) Intoxilyzer S-D5 manufactured by CMI, Inc. of Owensboro,
KY. This device is a hand-held device that uses a fuel cell sensor. (4)
The new Alco-Sensor III with serial numbers above 1,200,000. This is an
enhanced version of the earlier Alco-Sensor III. The enhanced version
has a new fuel cell and a microprocessor that improves performance. It
is a hand held device intended for stationary or roadside operations.
As indicated, it uses a fuel cell sensor and is powered by an internal
battery. (5) The Intox EC/IR 2 manufactured by Intoximeters, Inc. of
St. Louis, Missouri. This is a bench top device intended primarily for
use in stationary operations. It uses a fuel cell sensor and can be
powered by either 110 volts AC or 9 volts DC power sources. (6) The FC
10, manufactured by Lifeloc Technologies, Inc. of Wheat Ridge, CO. This
is a handheld device that uses a fuel cell sensor. (7) The FC 20, also
manufactured by Lifeloc Technologies, Inc. of Wheat Ridge, CO. This is
also a handheld device that uses a fuel cell sensor. The Lifeloc FC 20
is similar to the FC 10 except that it has additional features that are
not addressed by the model specifications.
Finally, three devices are being removed from the CPL, because they
are
[[Page 62092]]
no longer manufactured and are no longer in use. They are: (1)
Alco.Tector Model 500, manufactured by Decator Electronics of Decator,
Illinois. This device was introduced more than 30 years ago. It has not
been manufactured for at least 20 years, and its manufacturer is no
longer in existence. It would be impossible to repair because
replacement parts are not available. The agency has no knowledge of any
such devices in use. (2) The AE-D1 manufactured by Lion Laboratories,
Ltd. of Cardiff, Wales, UK. The manufacturer has confirmed in writing
that this unit is totally obsolete, no longer in use and no longer in
production. (3) The Auto-Alcolmeter manufactured by Lion Laboratories,
Ltd. of Cardiff, Wales, UK. The manufacturer has also confirmed in
writing that this unit is totally obsolete, no longer in use and no
longer in production.
The CPL has been amended to add the seven instruments identified
above to the list, and to remove the three instruments also identified
above.
In accordance with the foregoing, the CPL is therefore amended, as
set forth below.
Conforming Products List of Evidential Breath Measurement Devices
------------------------------------------------------------------------
Manufacturer and model Mobile Nonmobile
------------------------------------------------------------------------
Alcohol Countermeasure Systems Corp.,
Mississauga, Ontario, Canada:
Alert J3AD*....................... X X
Alert J4X.ec...................... X X
PBA3000C.......................... X X
BAC Systems, Inc., Ontario, Canada: X X
Breath Analysis Computer*............
CAMEC Ltd., North Shields, Tyne and X X
Ware, England: IR Breath Analyzer*...
CMI, Inc., Owensboro, KY:
Intoxilyzer Model:
200........................... X X
200D.......................... X X
300........................... X X
400........................... X X
400PA......................... X X
1400.......................... X X
4011*......................... X X
4011A*........................ X X
4011AS*....................... X X
4011AS-A*..................... X X
4011AS-AQ*.................... X X
4011 AW*...................... X X
4011A27-10100*................ X X
4011A27-10100 with filter*.... X X
5000.......................... X X
5000 (w/Cal. Vapor Re-Circ.).. X X
5000 (w/3/8'' ID Hose option). X X
5000CD........................ X X
5000CD/FG5.................... X X
5000EN........................ X X
5000 (CAL DOJ)................ X X
5000VA........................ X X
8000.......................... X X
PAC 1200*..................... X X
S-D2.......................... X X
S-D5.......................... X X
Draeger Safety, Inc., Durango, CO:
Alcotest Model:
7010*......................... X X
7110*......................... X X
7110 MKIII.................... X X
7110 MKIII-C.................. X X
7410.......................... X X
7410 Plus..................... X X
Breathalyzer Model:
900*.......................... X X
900A*......................... X X
900BG*........................ X X
7410.......................... X X
7410-II....................... X X
Gall's Inc., Lexington, KY: Alcohol X X
Detection System-A.D.S. 500..........
Intoximeters, Inc., St. Louis, MO:
Photo Electric Intoximeter*....... ............... X
GC Intoximeter MK II*............. X X
GC Intoximeter MK IV*............. X X
Auto Intoximeter*................. X X
Intoximeter Model:
3000*......................... X X
3000 (rev B1)*................ X X
3000 (rev B2)*................ X X
3000 (rev B2A)*............... X X
3000 (rev B2A) w/FM option*... X X
[[Page 62093]]
3000 (Fuel Cell)*............. X X
3000 D*....................... X X
3000 DFC*..................... X X
Alcomonitor....................... ............... X
Alcomonitor CC.................... X X
Alco-Sensor III................... X X
Alco-Sensor III (Enhanced with X X
Serial Numbers above 1,200,000)..
Alco-Sensor IV.................... X X
Alco-Sensor IV-XL................. X X
Alco-Sensor AZ.................... X X
RBT-AZ............................ X X
RBT III........................... X X
RBT III-A......................... X X
RBT IV............................ X X
RBT IV with CEM (cell enhancement X X
module)..........................
Intox EC/IR....................... X X
Intox EC/IR 2..................... X X
Portable Intox EC/IR.............. X X
Komyo Kitagawa, Kogyo, K.K.:
Alcolyzer DPA-2*.................. X X
Breath Alcohol Meter PAM 101B*.... X X
Lifeloc Technologies, Inc., (formerly
Lifeloc, Inc.), Wheat Ridge, CO:
PBA 3000B......................... X X
PBA 3000-P*....................... X X
PBA 3000C......................... X X
Alcohol Data Sensor............... X X
Phoenix........................... X X
FC 10............................. X X
FC 20............................. X X
Lion Laboratories, Ltd., Cardiff,
Wales, UK:
Alcolmeter Model:
300........................... X X
400........................... X X
SD-2*......................... X X
EBA*.......................... X X
Intoxilyzer Model:
200........................... X X
200D.......................... X X
1400.......................... X X
5000 CD/FG5................... X X
5000 EN....................... X X
Luckey Laboratories, San Bernadino,
CA:
Alco-Analyzer Model:
1000*......................... ............... X
2000*......................... ............... X
National Draeger, Inc., Durango, CO:
Alcotest Model:
7010*......................... X X
7110*......................... X X
7110 MKIII.................... X X
7110 MKIII-C.................. X X
7410.......................... X X
7410 Plus..................... X X
Breathalyzer Model:
900*.......................... X X
900A*......................... X X
900BG*........................ X X
7410.......................... X X
7410-II....................... X X
National Patent Analytical Systems,
Inc., Mansfield, OH:
BAC DataMaster (with or without X X
the Delta-1 accessory)...........
BAC Verifier Datamaster (with or X X
without the Delta-1 accessory)...
DataMaster cdm (with or without X X
the Delta-1 accessory)...........
Omicron Systems, Palo Alto, CA:
Intoxilyzer Model:
4011*......................... X X
4011AW*....................... X X
Plus 4 Engineering, Minturn, CO: 5000 X X
Plus4*...............................
Seres, Paris, France:
Alco Master....................... X X
Alcopro........................... X X
Siemans-Allis, Cherry Hill, NJ:
[[Page 62094]]
Alcomat*.......................... X X
Alcomat F*........................ X X
Smith and Wesson Electronics,
Springfield, MA:
Breathalyzer Model:
900*.......................... X X
900A*......................... X X
1000*......................... X X
2000*......................... X X
2000 (non-Humidity Sensor)*... X X
Sound-Off, Inc., Hudsonville, MI:
AlcoData.......................... X X
Seres Alco Master................. X X
Seres Alcopro..................... X X
Stephenson Corp.:
Breathalyzer 900*................. X X
U.S. Alcohol Testing, Inc./Protection
Devices, Inc., Rancho Cucamonga, CA:
Alco-Analyzer 1000................ ............... X
Alco-Analyzer 2000................ ............... X
Alco-Analyzer 2100................ X X
Verax Systems, Inc., Fairport, NY:
BAC Verifier*..................... X X
BAC Verifier Datamaster........... X X
BAC Verifier Datamaster II*....... X X
------------------------------------------------------------------------
* Instruments marked with an asterisk (*) meet the Model Specifications
detailed in 49 FR 48854 (December 14, 1984) (i.e., instruments tested
at 0.000, 0.050, 0.101, and 0.151 BAC.) Instruments not marked with an
asterisk meet the Model Specifications detailed in 58 FR 48705
(September 17, 1993), and were tested at BACs = 0.000, 0.020, 0.040,
0.080, and 0.160. All instruments that meet the Model Specifications
currently in effect (dated September 17, 1993) also meet the Model
Specifications for Screening Devices to Measure Alcohol in Bodily
Fluids.
(23 U.S.C. 402; delegations of authority at 49 CFR 1.50 and 501.1)
Issued on: September 27, 2002.
Marilena Amoni,
Associate Administrator for Program Development and Delivery.
[FR Doc. 02-25185 Filed 10-2-02; 8:45 am]