DEPARTMENT OF ENERGY
Office of Energy Efficiency and Renewable Energy
10 CFR Part 430
[Docket Number EE-RM-98-440]
RIN 1904-AA77
Energy Conservation Program for Consumer Products; Central Air
Conditioners and Heat Pumps Energy Conservation Standards
Correction
In rule document 02-12680 beginning on page 36368 in the issue of
Thursday, May 23, 2002, make the following correction:
[sect]430.32 [Corrected]
On page 36406, in [sect]430.32 (c)(2), the table should read as set
forth below.
(c)
* * * * *
(2) Central air conditioners and central air conditioning heat
pumps manufactured on or after January 23, 2006 , shall have Seasonal
Energy Efficiency Ratio and Heating Seasonal Performance Factor no less
than:
------------------------------------------------------------------------
Seasonal Heating
energy seasonal
Product class efficiency performance
ratio factor
(SEER) (HSPF)
------------------------------------------------------------------------
(i) Split system air conditioners.............. 12 --
(ii) Split system heat pumps................... 12 7.4
(iii) Single package air conditioners.......... 12 --
(iv) Single package heat pumps................. 12 7.4
(v)(A) Through-the-wall air conditioners and 10.9 7.1
heat pumps--split system......................
(v)(B) Through-the-wall air conditioners and 10.6 7.0
heat pumps--single package....................
(vi) Small duct, high velocity systems......... \1\ 10.0 \1\ 6.8
------------------------------------------------------------------------
\1\ NAECA-prescribed value subject to amendment.
* * * * *