NUCLEAR REGULATORY COMMISSION
[Docket No. 50-368]


Entergy Operations, Inc., (Arkansas Nuclear One, Unit 2); 
Exemption

I

    Entergy Operations, Inc. (the licensee) is the holder of Facility 
Operating License No. NPF-6, which authorizes operation of Arkansas 
Nuclear One, Unit 2. The license provides, among other things, that the 
licensee is subject to all rules, regulations, and orders of the 
Commission now or hereafter in effect.
    The facility consists of two pressurized water reactors, Arkansas 
Nuclear One, Units 1 and 2, located at the licensee's site in Pope 
County, Arkansas.

II

    In its letter dated April 11, 1996, the licensee requested an 
exemption from the Commission's regulations for Arkansas Nuclear One, 
Unit 2. Title 10 of the Code of Federal Regulations, Part 50, Section 
60 (10 CFR 50.60), ``Acceptance Criteria for Fracture Prevention 
Measures for Lightwater Nuclear Power Reactors for Normal Operation,'' 
states that all lightwater nuclear power reactors must meet the 
fracture toughness and material surveillance program requirements for 
the reactor coolant pressure boundary as set forth in Appendices G and 
H to 10 CFR Part 50. Appendix G to 10 CFR Part 50 defines pressure/
temperature (P/T) limits during any condition of normal operation, 
including anticipated operational occurrences and system hydrostatic 
tests to which the pressure boundary may be subjected over its service 
lifetime. It is specified in 10 CFR 50.60(b) that alternatives to the 
described requirements in Appendices G and H to 10 CFR Part 50 may be 
used when an exemption is granted by the Commission under 10 CFR 50.12.
    To prevent low temperature overpressure transients that would 
produce pressure excursions exceeding the Appendix G P/T limits while 
the reactor is operating at low temperatures, the licensee installed a 
low temperature overpressure protection (LTOP) system. The system 
includes two relief valves to limit high system pressure. The relief 
valves are set at a pressure low enough so that if an LTOP transient 
occurred, the mitigation system would prevent the pressure in the 
reactor vessel from exceeding the Appendix G P/T limits. To prevent the 
relief valves from lifting as a result of normal operating pressure 
surges (e.g., reactor coolant pump starting, and shifting operating 
charging pumps) with the reactor coolant system in a solid water 
condition, the operating pressure must be maintained below the relief 
valve setpoint. However, the reactor coolant system pressure/
temperature operating window at low temperatures is defined by the LTOP 
setpoint. Implementation of a LTOP setpoint without the additional 
margin allowed by American Society of Mechanical Engineers (ASME) Code

[[Page 4819]]

Case N-514 would restrict the pressure/temperature operating window and 
would potentially result in undesired actuation of the LTOP system. 
This constitutes an unnecessary burden that can be alleviated by the 
application of ASME Code Case N-514. Implementation of an LTOP setpoint 
as allowed by ASME Code Case N-514 does not significantly reduce the 
margin of safety associated with normal operational heatup and cooldown 
limits. Further, the LTOP guidelines will reduce the potential for an 
undesired lift of the LTOP valves.
    The licensee has requested the use of the American Society of 
Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (Code) Case 
N-514, ``Low Temperature Overpressure Protection,'' which allows 
exceeding the Appendix G safety limits by 10 percent. ASME Code Case N-
514, the proposed alternate methodology, is consistent with guidelines 
developed by the ASME Working Group on Operating Plant Criteria to 
define pressure limits during LTOP events that avoid certain 
unnecessary operational restrictions, provide adequate margins against 
failure of the reactor pressure vessel, and reduce the potential for 
unnecessary activation of pressure-relieving devices used for LTOP. 
Code Case N-514 has been approved by the ASME Code Committee. The 
content of this code case has been incorporated into Appendix G of 
Section XI of the ASME Code and published in the 1993 Addenda to 
Section XI.

III

    Pursuant to 10 CFR 50.12, the Commission may, upon application by 
any interested person or upon its own initiative, grant exemptions from 
the requirements of 10 CFR Part 50 when (1) the exemptions are 
authorized by law, will not present an undue risk to public health or 
safety, and are consistent with the common defense and security; and 
(2) when special circumstances are present. Special circumstances are 
present whenever, according to 10 CFR 50.12(a)(2)(ii), ``Application of 
the regulation in the particular circumstances would not serve the 
underlying purpose of the rule or is not necessary to achieve the 
underlying purpose of the rule * * *.''
    The underlying purpose of 10 CFR 50.60, Appendix G, is to establish 
fracture toughness requirements for ferritic materials of pressure-
retaining components of the reactor coolant pressure boundary to 
provide adequate margins of safety during any condition of normal 
operation, including anticipated operational occurrences, to which the 
pressure boundary may be subjected over its service lifetime. Section 
IV.A.2 of this appendix requires that the reactor vessel be operated 
with P/T limits at least as conservative as those obtained by following 
the methods of analysis and the required margins of safety of Appendix 
G of the ASME Code.
    Appendix G of the ASME Code requires that the P/T limits be 
calculated: (a) using a safety factor of two on the principal membrane 
(pressure) stresses, (b) assuming a flaw at the surface with a depth of 
one-quarter (\1/4\) of the vessel wall thickness and a length of six 
(6) times its depth, and (c) using a conservative fracture toughness 
curve that is based on the lower bound of static, dynamic, and crack 
arrest fracture toughness tests on material similar to the ANO-2 
reactor vessel material.
    In determining the setpoint for LTOP events, the licensee proposed 
to use safety margins based on an alternate methodology consistent with 
the ASME Code Case N-514 guidelines. The ASME Code Case N-514 allows 
determination of the setpoint for LTOP events such that the maximum 
pressure in the vessel would not exceed 110 percent of the P/T limits 
of the existing ASME Appendix G. This results in a safety factor of 1.8 
on the principal membrane stresses. All other factors, including 
assumed flaw size and fracture toughness, remain the same. Although 
this methodology would reduce the safety factor on the principal 
membrane stresses, the proposed criteria will provide adequate margins 
of safety to the reactor vessel during LTOP transients and, thus, will 
satisfy the underlying purpose of 10 CFR 50.60 for fracture toughness 
requirements. The slight reduction in the membrane stress safety 
factor, as proposed by Code Case N-514, is compensated by increased 
safety from the standpoint of increased operational flexibility and the 
reduced potential for unnecessary opening of the LTOP relief valves. In 
summary, the use of Code Case N-514 is likely to improve overall safety 
when evaluated as part of the complete plant safety concern.

IV

    For the foregoing reasons, the NRC staff has concluded that the 
licensee's proposed use of the alternate methodology in determining the 
acceptable setpoint for LTOP events will not present an undue risk to 
public health and safety and is consistent with the common defense and 
security. The NRC staff has determined that there are special 
circumstances present, as specified in 10 CFR 50.12(a)(2), in that 
application of 10 CFR 50.60 is not necessary in order to achieve the 
underlying purpose of this regulation.
    Accordingly, the Commission has determined that, pursuant to 10 CFR 
50.12(a), an exemption is authorized by law, will not endanger life or 
property or common defense and security, and is, otherwise, in the 
public interest. Therefore, the Commission hereby grants an exemption 
from the requirements of 10 CFR 50.60 allowing the use of alternate 
criteria as described by Code Case N-514, which permits exceeding the 
Appendix G safety factor by 10 percent during low temperature 
operations.
    Pursuant to 10 CFR 51.32, the Commission has determined that the 
granting of this exemption will not have a significant effect on the 
quality of the human environment (61 FR 20846).
    This exemption is effective upon issuance.

    Dated at Rockville, Maryland, this 28th day of January 1997.

    For the Nuclear Regulatory Commission.
Frank J. Miraglia,
Acting Director, Office of Nuclear Reactor Regulation.