NUCLEAR REGULATORY COMMISSION
[Docket No. 50-397]


Exemption

    In the matter of Washington Public Power Supply System; (WPPSS 
Nuclear Project No. 2).

I

    On December 20, 1983, the Commission issued Facility Operating 
License No. NPF-21 to Washington Public Power Supply System (the 
licensee) for the WPPSS Nuclear Project No. 2. The license provides, 
among other things, that the licensee is subject to all rules, 
regulations, and orders of the Commission now or hereafter in effect.

II

    It is stated in 10 CFR 73.55, ``Requirements for physical 
protection of licensed activities in nuclear power reactors against 
radiological sabotage,'' paragraph (a), that ``the licensee shall 
establish and maintain an onsite physical protection system and 
security organization which will have as its objective to provide high 
assurance that activities involving special nuclear material are not 
inimical to the common defense and security and do not constitute an 
unreasonable risk to the public health and safety.''
    It is specified in 10 CFR 73.55(d), ``Access Requirements,'' 
paragraph (1), that ``the licensee shall control all points of 
personnel and vehicle access into a protected area.'' Section 
73.55(d)(5) requires that ``a numbered picture badge identification 
system shall be used for all individuals who are authorized access to 
protected areas without escort.'' Section 73.55(d)(5) also states that 
an individual not employed by the licensee (e.g., contractors) may be 
authorized access to protected areas without escort provided the 
individual ``receives a picture badge upon entrance into the protected 
area which must be returned upon exit from the protected area.''
    The licensee proposed to implement an alternative unescorted access 
control system which would eliminate the need to issue and retrieve 
badges at the entrance/exit location and would allow all individuals 
with unescorted access to keep their badge with them when departing the 
site.
    An exemption from 10 CFR 73.55(d)(5) is required to allow personnel 
not employed by the licensee who have unescorted access to take their 
badges offsite instead of returning them when exiting the site. By 
letter dated March 1, 1995, the licensee requested an exemption from 
certain requirements of 10 CFR 73.55(d)(5) for this purpose.

III

    Pursuant to 10 CFR 73.5, ``Specific exemptions,'' the Commission 
may, upon application of any interested person or upon its own 
initiative, grant such exemptions in this part as it determines are 
authorized by law and will not endanger life or property or the common 
defense and security, and are otherwise in the public interest.
    Pursuant to 10 CFR 73.55, the Commission may authorize a licensee 
to provide alternative measures for protection against radiological 
sabotage provided the licensee demonstrates that the alternative 
measures have ``the same high assurance objective'' and meet ``the 
general performance requirements'' of the regulation, and ``the overall 
level of system performance provides protection against radiological 
sabotage equivalent'' to that which would be provided by the 
regulation.
    Currently, unescorted access to the protected area of WNP-2 is 
controlled through the use of a photograph on a badge with a keycard 
attached (hereafter, these are referred to as ``the badge''). The 
security officers at the entrance station use the photograph on the 
badge to visually identify the individual requesting access. The 
individual is then given the badge to allow access. The badges for both 
licensee employees and contractor personnel who have been granted 
unescorted access are issued upon entrance at the access point. Another 
security officer in the same control area collects the badges upon exit 
from the protected area. The badges are then placed in a badge rack 
located at the badge issue station and stored at the entrance until the 
individual again needs access into the protected area. In accordance 
with 10 CFR 73.55(d)(5), individuals not employed by the licensee 
(e.g., contractors) are not allowed to take badges offsite.
    Under the proposed system, each individual who is authorized for 
unescorted entry into the protected area would have the physical 
characteristics of their hand (hand geometry) registered with their 
badge number in the access control computer. Access is then initiated 
by the individual requesting access by placing their badge up to the 
card reader and their hand on a measuring surface. The computer then 
compares the hand geometry to that registered for the badge number. If 
the characteristics of the hand geometry stored in the computer match 
the badge number, access is granted. If the characteristics of the hand 
geometry do not match the badge number, access is denied. This provides 
a non-transferable means of identifying that the individual processing 
the badge is the individual who was granted unescorted access. This 
method also provides a positive means of assuring that a stolen or lost 
badge could not be used to gain access, thus eliminating the need to 
issue and retrieve the badges while maintaining the same high level of 
assurance that access is granted to only authorized individuals. All 
other access processes, including search function capability, would 
remain the same. The system will not be used for visitors requiring 
escorted access. The access process will continue to be under the 
observation of security personnel located within the 

[[Page 38062]]
hardened cubicle who have final control over the release of the 
entrance station turnstiles. A numbered badge identification system 
will continue to be used for all individuals who are authorized access 
to the protected areas. Badges will continue to be displayed by all 
individuals while inside the protected area.
    The licensee will use hand geometry equipment that will meet the 
detection probability of 90 percent with a 95 percent confidence level. 
Testing evaluated by Sandia National Laboratory (Sandia report 
entitled, ``A Performance Evaluation of Biometric Identification 
Devices,'' SAND91-0276 UC-906 Unlimited Release, printed June 1991), 
demonstrated that the proposed hand geometry system is capable of 
meeting the proposed detection probability and confidence level. Based 
on the results of the Sandia report and on the licensee's experience 
with photo-identification processes, the proposed system will have a 
false acceptance rate less than the current system.
    For the foregoing reasons, pursuant to 10 CFR 73.55, the NRC staff 
has determined that the proposed alternative measures for protection 
against radiological sabotage meet the same high assurance objective 
and the general performance requirements of the regulation, and that 
the overall level of system performance provides protection against 
radiological sabotage equivalent to that which would be provided by the 
regulation.
    Accordingly, the Commission has determined that, pursuant to 10 CFR 
73.5, this exemption is authorized by law, will not endanger life or 
property or the common defense and security, and is otherwise in the 
public interest. Therefore, the Commission hereby grants the Washington 
Public Power Supply System an exemption from the requirements of 10 CFR 
73.55(d)(5) relating to the returning of picture badges, by individuals 
not employed by the licensee who are authorized unescorted access to 
the protected area, upon exit from the protected area, such that these 
personnel can take their badges offsite.
    Pursuant to 10 CFR 51.32, the Commission has determined that the 
granting of this exemption will not result in any significant adverse 
environmental impact (60 FR 35965).
    This exemption is effective upon issuance.

    Dated at Rockville, Maryland this 17th day of July 1995.

    For the Nuclear Regulatory Commission.
Jack W. Roe,
Director, Division of Reactor Projects III/IV, Office of Nuclear 
Reactor Regulation.
[FR Doc. 95-18195 Filed 7-24-95; 8:45 am]