<?xml version="1.0" encoding="iso-8859-1" ?>
<doc callnum="TP233 .I47 1981">
<metadata>
	<titleStmt>
		<mainTitle nfc="0"><title>Impact assessment of Ammonia and Chlorine transshipment relative to commercial OTEC plant operation in Guam, USA</title>:<titleExt>a study / conducted for Guam Guam Energy Office, Energy Impact Program ; by Pacific Energy Management Consultants.</titleExt></mainTitle>
	</titleStmt>
	<authorStmt>
		<corpAuthor><name>Guam Energy Office.</name></corpAuthor>
		<corpAuthor><name>Pacific Energy Management Consultants.</name></corpAuthor>
	</authorStmt>
	<imprint><pubPlace>Tamuning, Guam</pubPlace>:<pubName>The Consultants</pubName>,<pubDate>1981.</pubDate></imprint>
	<classStmt>
		<locClass>
			<subject cat="top">Ammonia</subject>
			<subject cat="gen">Transportation</subject>
			<subject cat="gen">Safety measures</subject>
			<subject cat="geo">Guam.</subject>
		</locClass>
		<locClass>
			<subject cat="top">Chlorine</subject>
			<subject cat="gen">Transportation</subject>
			<subject cat="gen">Safety measures</subject>
			<subject cat="geo">Guam.</subject>
		</locClass>
		<locClass>
			<subject cat="top">Hazardous geographic</subject>
			<subject cat="gen">Environmental aspects</subject>
			<subject cat="geo">Guam.</subject>
		</locClass>
		<locClass>
			<subject cat="top">Ocean thermal power plants</subject>
			<subject cat="geo">Guam.</subject>
		</locClass>
	</classStmt>
</metadata>

<text xml:space="preserve">
<pb n="1" />

        ALENTOS GIYA GUAHAN

       ENERGY -ON GUAM

                                                                             NH3

                                                                                                          CHLORI NE

                                                                                                           CL2

                                     COASTAL ZCI@2
       U5,
                                INZORMATION CEj\jTZj
                                                                         IMPACT ASSESSMENT OF
                                                                        'AMMONIA AND CHLORINE
                                                                         TRANSSHIPMENT RELATIVE
                                                                         TO COMMERCIAL OTEC
                                                                         PLANT OPERATION IN
                                                                         GUAM, USA

       61
                                                                         GUAM ENERGY OFFICE
                                                                         TECHNICAL REPORT N08102

               TP
               233
               147
               1981
                            GUAM        ENERGY OFFICE

      P.O. BOX 2950, AGANA, GUAM 96910     472-8711, 477-9445, 477-9526
<pb n="2" />

                                                    Prepared by:

                               PACIFIC ENERGY MANAGEMENT CONSULTANTS

                                       Guam Office: Harmon Plaza, Wing D.
                                      Post Office Box 8888 * Tamuning, Guam 96911
                                        Tel. 646-8606, 646-1558;Telex 721 6295
                                           Honolulu Office: 458A Keawc St.
                                               Honolulu, Hawaii 96813
                                          Tel. (808) 521-2943; Telex: 723-8768
<pb n="3" />

                          IMPACT ASSESSMENT OF AMMONIA AND CHLORINE

                          TRANSSHIPMENT RELATIVE TO COMMERCIAL OTEC

                                PLANT OPERATION IN GUAM, USA

                                   A STUDY CONDUCTED FOR
     oc@                           THE GUAM ENERGY OFFICE

                                     GOVERNMENT OF GUAM

                               COASTAL ENERGY IMPACT PROGRAM

                                   PAUL M. CALVO, GOVERNOR

                                   JAY L. LATHER, DIRECTOR

      Cq1
                                            by

                            PACIFIC ENERGY MANAGEMENT CONSULTANTS

                                       P.O. BOX 8888

                                    TANNING, GUAM 96911

                                       February, 1981

             This report  is funded under  a  grant provided by Coastal   Zone
             Management, Act of 1972, as amended, administered by the Office of
             Coastal   Zone Management,   National  Oceanic  and   Atmospheric
             Administration.
<pb n="4" />

                  Pacific Energy Management Consultants was contracted to perform

              an assessment of the Marine Terminal Facilities at Apra Harbor, Guam

              with respect to the movement of large quantities of ammonia and

              chlorine.    This study was funded under a grant provided by the

              Coastal Energy Impact Program and administered by the Guam Energy

              Office, Jay L. Lather, Director, under Document Number C-0-3400017,

              Job Order Number 34000160/130, dated August 6, 1980.
<pb n="5" />

                                                 TABLE OF CONTENTS                       Page

                SUMMARY  ..............................................................     I

                CHAPTER 1 INTRODUCTION

                ].'I Study Objectives   ...............................................     3
                1.2 Study Methodology     ..............................................    3
                1.3 Report Forma@     .................................................     5

                CHAPTER Il THE ROLES OF COMMERCIAL PORT OF GUAM AND THE
                             PROPOSED OTEC PLANT IN NH3 AND CL2 TRANSFER

                2.1 The OTEC Concept    ...............................................     6
                2.2 Commercial Port of Guam     ........................................    8
                2.3 Proposed OTEC Plant Site    .......................................     9

                CHAPTER III QUANTITIES AND PROPERTIES OF AMMONIA

                3.1 Required Quantities and Importation of Ammonia      .................  12
                3.2 Properties and Hazards of Ammonia      ..............................  13

                CHAPTER IV HAZARDS AND SAFETY PRECAUTIONS FOR AMMONIA

                4.1   General ......................                                   ... 15
                4.?   Ammonia Vapor Hazards   ..........................................   16
                4.3   Personal Protective Equipment    ..................................  17
                4.4   Storage Area Precautions  .......................................    18
                4.5   Labeling/Posting  ...............................................    18
                4.6   Fire Hazard  ....................................................    19
                4.7   Leak Hazard  ....................................................    19
                4.8   Health Hazards  .................................................    20

                     4.8.1 Warning Properties   .......................................    20
                     4.8.2 Severe Exposure    ..........................................   21
                     4.8.3 Exposure Countermeasures     .................................  21

                          4.8.3 (a)   Inhalation   ......................................  21
                          4.8.3 (b)   Taken Internally   ................................  22
                          4.8.3 (c)   Contact With the Eyes   ...........................  22
                          4.8.3 (d)   Contact With Skin and Mucous Membranes    .......... 23

                     4.8.4 Procedures for Obtaining Medical Assistance      .............. 23
                     4.8.5 Suggestions to Physicians     ................................  24

                4.9 Personnel Safety Training      ......................................  25

                     4.9.1 Informing Employees of Hazards of Ammonia     ................. 25
                     4.9.2 Training and Drills     ......................................  26
<pb n="6" />

                 CHAPTER V TRANSPORTATION OF AMMONIA

                 5.1 Containerized Break-bulk Shipment       ...............................    28
                 5.2 Bulk Shipment     ...................................................      30

                      5.2.1 Ammonia   Pipelines   .........................................     30

                            5.2.1 (a)  Pipeline Leaks    ...................................    32
                            5.2.1 (b)  Routing   ..........................................     33
                            5.2.1 (c)  Government Regulations     ............................  33
                            5.2.1 (d,, Design   ...........................................     33
                            5.2.1 (e)  Installation    .....................................    34

                      5.2.2 Tank Trucks     ...............................................     35

                            5.2.2 (a) Trailer and Semitrailer Requirements       .............  35
                            5.2.2 (b) Protection Against Collision       .....................  36
                            5.2.2 (c) Safety Equipment     .................................    36

                 CHAPTER VI CHLORINE PROPERTIES AND REQUIREMENTS

                 6.1 Required Quantities and Importation Of C12        ......................   37
                 6.2 Properties and Hazards of Chlorine        ..............................   38

                 CHAPTER VII HAZARDS AND SAFETY PRECAUTIONS FOR CHLORINE

                 7.1   General  .........................................................       40
                 7.2   Chlorine Vapor Hazards    ..........................................     41
                 7.3   Personal Protective Equipment     ...................................    42
                 7.4   Storage Area Precautions     ........................................    42
                 7.5   Labeling/Posting    ................................................     44
                 7.6   Container Handling Procedures     ...................................    44
                 7.7   Trailer and Semitrailer Requirements      ............................   45
                 7.8   Fire Hazard   .....................................................      46
                 7.9   Leak Hazard   .....................................................      47
                 7.10  Health Hazards   .....................................     ............. 49

                      7.10  (a)  Warning Properties    .....................................    49
                      7.10  (b)  Severe Exposures    .......................................    49
                      7.10  (c)  Exposure Countermeasures     ...............................   50

                            7.10 (c)(1) General     ........................................    50
                            7.10 (c)(2) Gas Inhalation      ..................................  50
                            7.10 (c)(3) Chlorine Eye Contact      ...........................   51
                            7.10 (c)(4) Chlorine Skin Contact      ..........................   51

                      7.10  (a)  Procedures for Obtaining Medical Assistance      ...........   51

                 7.11 Personnel Safety Training       ......................................    52

                      7.11 (a) Informing Employees of Hazards of Chlorine         ............. 52
                      7.11 (b) Training ano Drills      ....................................    53
<pb n="7" />

                  CHAPTER VIII TRANSPORTATION OF CHLORINE

                  8.1 break-bulk Shipment       .............................................         55
                  8.2 Ton Containers     ..................................................           56

                  CHAPTER IX GOVERNMENT AUTHORITY AND REGULATIONS FOR
                                HANDLING AMMONIA

                  9.1 U.S. Coast Guard       ................................................         59

                      9.1.1 Statutory Authority         .......................................       60

                             9.1.1 (a)   Title 33 CFR 6.12      ................................      60
                             9.1.1 (b)   Title 33 CFR 6.14      ................................      61
                             9.1.1 (c)   Ports and Waterways Safety Act of 1972          ...........  61
                             9.1.1 (d)   Section 311 of the FWPCA      ........................     . 61
                             9.1.1 (e)   Executive Order 11735       ............................     62

                      9.1.2 Local Coast Guard Requirements           ............................     62

                             9.1.2 (a) Possible Vessel Requirements          .....................    63
                             9.1.2 (b) Possible Facility Requirements          ...................    64

                      9.1.3 Facility of Particular Hazard           .............................     65

                  9.2 U.S. Environmental Protection Agency           ............................     65
                  9.3 Occupational Safety and Health Administration            ...................    67

                  CHAPTER X SUMMARY OF TASK

                  10.1   Determine Quantity, Mode and Frequency of
                         Hazardous Chemical Shipments        ...................................      69
                  10.2   Deterine Storage Area Needs       ....................................       70
                  10.3   Coordinate with U.S.C.G     . .......................................        71
                  10.4   Determine Medical Facilities and Support Available            .............  71
                  10.5   Coordinate With Fire Department        ................................      73
                  10.6   Establish Employee Education and Training          ......................    73
                  10.7   Establish a Written Contingency Plan for Emergencies            ...........  74

                  APPENDICES

                  A-1        Footnotes
                  A-2        Bibliography
<pb n="8" />

                                                        TABLES

                TABLE                                                                      PAGE

                3-1       Chemical ana Physical Properties of Ammonia    ................  14A

                4-1       Evacuation Table for Ammonia   ...............................   16A

                4-2       Physiological Effects of Ammonia   ...........................   21A

                6-1       Chemical and Physical Properties of Cholorine    ..............  39A

                7-1       Evacuation Table for Chlorine   ..............................   54A
<pb n="9" />

                FIGURE                                FIGURES                            PAGE

                2-1      OTEC System Schematic   ......................................     7A

                2-2      Guam Commercial Port Transit.route for
                         NH3 and C12 to OTEC Site   ...................................     8A

                4-1      Ammonia Shipping Label   .....................................    18A

                7-1      Chlorine Shipping Label  ............  .......................    44A
<pb n="10" />

                                                   SUMMARY

                  A large and varied transportation system exists that can move ammonia

              and chlorine from producing plants to the OTEC storage tanks.

                  Anhydrous ammonia and chlorine can be transported to Guam in bulk,

              handled and stored safely if standard          industry safety practices       are

              followed.    The transshipment would not create unreasonable health or

              safety hazards.

                   Shipment of the chemicals in bulk quantities will require personnel

              specifically qualifieu in the bulk transfer of the chemicals involved.

              The Coast Guard will require that satisfactory documentary evidence be

              furnished as proof that the person in charge is capable of competently

              performing all potential operations that could evolve in a cargo transfer

              of a hazardous chemical.      OTEC plant technicians may be able to perform

              this function.

                   Bulk   shipments   of   these  chemicals    will  require    additional

              equipment in the form of a pipeline or tank trucks specifically

              designed for that chemical, in order to transport the chemical from

              the Commercial Port to the OTEC plant storage tanks.
<pb n="11" />

                     The facilities at the Commercial Port are best suited for any

                handling and transfer of ammonia and chlorine as compared to

                privately maintained facilities adjacent to the Commercial Port.

                The port would primarily serve a function as a transshipment center

                and storage area for the chemicals.

                     A   comprehensive    plan,   to   include    procedures   for     general

                emergencies, fire control, emergency lighting and power systems,

                first aid, dock emergencies, and responses to releases of all

                hazardous substances as well as routine Commercial Port operations,

                should be formulated as soon as possible.

                                                       2
<pb n="12" />

                                             CHAPTER I

                                            IMODUCTION

              1.1 Study Objectives

                  The objective of this study is to develop a detailed report on

              all of the parameters embracing the transfer of large quantities of
              anhydrous   ammonia  (NH 3)  and  chlorine   (C12)  at  the   Commercial
              Port of Guam for delivery to a proposed Ocean Thermal              Energy

              Conversion plant (OTEC).      The study focuses on the Commercial

              Port's   involvement in transportation, handling and storage of these

              two chemicals in the quantities anticipated.     The OTEC plant site is

              presumed to be the Cabras Island site designated by the Government

              of Guam although transshipment of chemicals to a possible sea based

              plant is also discussed.     The study considers ammonia and chlorine

              transshipment and is not intended to address details of on-site

              storage.

              1.2 Study Methodology

                  This study was conducted under the authority of the U.S. Coastal

              Energy Impact Program (CEIP).     The purpose of the CEIP is to study

              and plan for any economic, social or environmental consequence that

              is likely to occur as a result of siting, constructing, or expanding

              energy facilities within the coastal zone.

                                                  3
<pb n="13" />

                    This   study   relied    on existing literature        concerning     the

                transportation,    handling   and   storage   of  anhydrous    ammonia    and

                chlorine and the conceptual and preliminary design studies on OTEC

                performed by Westinghouse and TRW.        Department of Energy Document:
                Ocean Thermal Energy Conversion Power System Development1l I was

                used as a refereice for conceptual design of the OTEC plant.

                Anticipated quantitles of anhydrous ammonia and chlorine needed to

                operate a 50 MWe OTEC plant were extrapolated from data contained in

                these volumes.

                    The transportation, handling and storage of anhydrous ammonia

                and chlorine are regulated primarily by three government agencies:

                the   U.S.   Coast    Guard,    Environmental    Protection    Agency     and

                Occupational Safety and Health Administration. Relevant regulations

                of these agencies are discussed throughout the report as they

                pertain to Commercial Port operations.

                    The Chlorine Institute, Inc. and The Fertilizer Institute are

                private, nonprofit trade associations organized for the purpose of

                promoting safety in all aspects of production, handling and use of

                chlorine and anhydrous ammonia respectively.           Their publications

                were used extensively in the writing of this report.

                                                      4
<pb n="14" />

             1.3 Report Format

                Chlorine and anhydrous ammonia are individually classified as

             nonflammable and nonexplosive; they may react violently when      in

             contact with each other.   Given their divergent chemical natures,

             ammonia and chlorine are treated as distinct segments within the

             report to as great an extent as possible.

                 Chapter Il deals with aspects common to both ammonia and

             chlorine regarding the Commercial Port and the use of the chemicals

             in the OTEC plant.   Thereafter anhydrous ammonia is discussed in

             chapters III thru V and chlorine is discussed in chapters VI thru

             Vill.

                                               5
<pb n="15" />

                                                CHAPTER II

                    THE ROLES OF COMMERCIAL PORT OF GUAM AND THE PROPOSED OTEC PLANT

                                         IN NH 3 AND CL2 TRANSFER

                2.1 The OTEC Concert

                    Guam, with almost total dependence on imported petroleum to meet

                its increasing energy neeos, has recognized the need to develop

                renewable energy resources.      Wind, solar and OTEC technology are

                available now, but OTEC is the singular viable baseload alternate

                energy resource at this time.

                    Ocean Thermal Energy Conversion is a method for converting the

                solar energy stored in warm tropical waters into electrical energy.

                Approximately one million kilocalories per square yard per year of
                solar radiation fall on the earth's surfacej 2 1        The oceans store

                immense quantities of this incident solar energy in the form of

                heat.   Stored thermal energy can be converted to electrical energy

                in a heat engine by utilizing the warm surface waters as a heat

                source and the cold deeper waters as a heat sink.         Because of the

                high entropy character of this stored energy and the low resulting

                efficiency of the heat engine, maximum achievable efficiencies of an

                Ocean Thermal Energy Conversion plant range between four to ten

                                                     6
<pb n="16" />

               percent.L3 J   This means that very large quantities of water must

               be moved to extract usable amounts of energy.       However, the amount

               of available energy is nearly limitless.

                   The proposed OTEC plant will utilize anhydrous ammonia as a

               working fluid.   Using warm seawater as a heat source, the ammonia is

               changea from liquid to vapor within a       heat exchanger.    The vapor

               then turns a turbine that is connected      to an electrical generator.

               The ammonia vapor is then recondensed       in a second heat exchanger

               using cold, deep ocean water which has      been pumped to the surface.

               This cycle is repeated continuously. (Figure 2-1)

                   Biofouling is the growth and deposition of marine organisms on

               surfaces in contact with seawater.      Prevention of biofouling is an

               important   consideration    for   maximizing   heat   transfer     rates.

               Although biofouling rates are considerably less on Guam compared

               with mainland and Hawaii sites, the plant will probably utilize

               chlorine to prevent biofouling of heat transfer and hydraulic

               systems. The neea for continuous chlorination is assumed, requiring

               large quantities of the chemical.       Most of the plant's chlorine

               needs can be generated on site, as hypochlorite, by electrolysis.

               This is discussed further in Chapter VI.

                   Both ammonia and chlorine have unique individual and combined

               hazard traits.     Hazards associated with the handling of these

               chemicals by the Commercial Port will be discussed as they pertain

               to Commercial Port operations.

                                                    7
<pb n="17" />

          WARM Kk-rER                                        COL-D
            (NTAKE              F:1 -,-r7-gclTy ou-r          ou

                   Fump

                                       RBINE

                          \rA

  e0FORMOR                                           .4

               La L4 La U
                                FLUID       C(D
                                         CIF:;Zr,-ULA-nNG PUMP
                                           PUMP          COLD V4

                                                                FIG
                                                         OTEC   SY-1
          KARM INATER
 SOURCE:   OUTLF-T                                       (FOFR ELECTF
 GUAM ENERGY oFFice                                      PACIFIC ENER
 GOVMNMENT OF GUAM                                       P.
  m M, m m                      m JIM! m m m Mll@&amp;Wxlw
<pb n="18" />

               2.2 Commercial Port of Guam

                   Ammonia   and    chlorine   must    be   imported    to   Guam,    thus

               necessitating handling and possit)le storage of these chemicals at

               the Commercial    Port.   The Port of Guam      is the only commercial

               seaport on Guam and the principal seaport in Micronesia.             It is

               located at the northeast corner of Apra Harbor. The Commercial Port

               is vital to Guam because of the import-dependent nature of the local

               economy.

                   The Commercial Port consists of a total of 32 acres of land area

               presently comprising 12 acres of container yard and 2,700 feet of

               wharf.   The land area will increase substantially if the recently

               completed Commercial Port Master Plan        (dated September 1980)       is
               executed.L4 I    The facilities at the Commercial Port are best

               suited for any handling and transfer of ammonia and chlorine for

               OTEC, in comparison to private facilities in the Cabras Industrial

               Park area.

                   Approximately 85% of the Port's total annual volume of 650,000

               gross revenue tons     is   containerized cargo.     Crude oil,     refined

               petroleum products and      cement are transferred through privately

               maintained facilities in    the Cabras Island Industrial Park, adjacent

               to the Commercial Port.     Figure 2-2 depicts present configuration of

               the Commercial Port and surrounding area.

                                                     8
<pb n="19" />

                     At  the   present   t i me, Guam   i s served   by  eleven     regularly

                scheduled steamship lines,       two  in the United States-Guam trade,

                seven   in  inter-regional   trade with foreign areas,       and three     in

                intra-regional trade including transhipment with Micronesia.

                2.3 Proposed OTEC Plant Site

                     The prime consideration in siting a land-based OTEC plant is

                proximity to cold, deep, ocean water which can be pumped a minimum

                distance to the facility. Proximity of the OTEC plant to deep ocean

                waters reduces the costs of construction and minimizes the warming

                of the cold water prior to its delivery at the plant.

                     An additional site consideration for an OTEC plant is its need

                for an extensive electrical distribution network.         Proximity to the

                existing   power   plants   will   preclude    construction    of   a   major

                electrical network for the plant.

                     The  requirements    for   deep   ocean   water   and   an    electrical

                distribution network are both met by the proposed location on Cabras

                Island, (see Figure 2-2).       Waters 3,000 feet deep occur within a

                mile from shore. In addition, the proposed site is adjacent to the

                Piti and Cabras power plants which comprise the major electrical

                switching center for Guam.

                                                      9
<pb n="20" />

                                                 PHI LIPP I NE        S I- A

             PETROLEUM PROD    COR'NNER AND.        CDNTAINER YARD
                               BREAK -BULK
                               GEW-F"L CAF@so

                                FF:U=-S H &amp;
                               FPCZEN RSH                    CCNTAJNE:Z %-6kFRn
                                                              EX7_ENSfC)N

                   3 0

                                                    0           sm No
                                                         !Fl@  WN-ANE@@
                        EVLK CEMEN-r                     bCQ&amp;L SER7N                                           s F
                                                                                                              E
                 U - S, N A\I--r

                APRA HARBOR

            LEGEND-                                      PROJECT
                       7FRANSIT RCU=                     LOCATION
                       EOF:;.' NHa S&amp; C22.

                                                                                                             GU
                                                                                   GUAM                       Trou
                                                                                                             to

                                                                                                             PACIFIC

                                                                                          8A                P.O. eo
<pb n="21" />

                   1he '1980 Master Plan for the Commercial Port and surrounding

               area recommends that the land northwest of Cabras Power Plant be

               reserveo for the OTEC plant or for an alternative coal storage

               site.   This area is approximately one mile from the Commercial Port

               and adjacent to the power plants.

                   The focus of this study is on the land-based OTEC plant.             Guam

               is unique in its proximity to deep ocean water which can be pumped a

               short distance to the OTEC plant.          Waters 3,000 feet deep occur

               close to shore in the vicinity of the glass breakwater.

                   An alternative to the land-based system is the sea-based OTEC

               facility.   The OTEC equipment would be contained in a large vessel

               commonly called a platform.        Several designs have been proposed,

               either dynamically positioned or moored. A sea-based facility would

               be positioned about 1-1/2 miles off the Glass Breakwater and the

               mouth of Apra Harbor.

                   The considerations and constraints associated with a land-based

               OTEC plant would be relevant to a sea-based system.          The Commercial

               Port would primarily serve a function as a transshipment center and

               storage    area   for   anhydrous    ammonia    and   chlorine.      Handling

               procedures, health hazards, personal protective equipment and such

               like would be equally applicable to transshipment operations.             The

               potential for an accident would be increased somewhat due to the

               increased handling of the products.

                                                     10
<pb n="22" />

                   The initial shipment of ammonia can be delivered directly to the

               OTEC platform without any need for Commercial Port handling of the

               chemical.   Subsequent shipments of make up quantities in containers

               would involve the port in handling and storage.

                   A sea-based plant would necessitate storage of chemical at the

               Commercial Port given the limited space on board the platform and

               the shipping distances and time frames involved in re-supply from

               off-island.   The additional space needed cannot be quantified at

               this time.    If the recommended expansion of the container yard is

               undertaken, ample storage area will be available.

                   A sea-based plant would increase the Commercial Ports handling

               and storage of hazardous chemical and would effect the quantity,

               mode and frequency of hazardous chemical shipments.
<pb n="23" />

                                               CHAPTER III

                                 QUANTITIES AND PROPERTIES OF AMMONIA

               3.1 Required Quantities And Importation of Ammonia

                   Ammonia has been produced commercially for use in refrigeration

               equipment for at     least one hundred years.        A large and varied

               transportation system exists that can move ammonia from producing

               plants to the OTEC storage tanks.

                   Ammonia is stored as a liquid either in-refrigerated tanks at

               atmospheric pressure or      in unrefrigerated carbon      steel   pressure

               vessels.    In order to avoid the operating and maintenance costs

               involved with a refrigerated system, the ammonia system for the OTEC

               plant includes pressurized storage vessels.

                   The ammonia storage system for the 50 MWe OTEC plant is

               anticipated to consist of fourteen 30,000 gallon pressurized vessels
               or a total of 420,000 gallons.[5 I       These tanks will be located at

               the OTEC plant site.     There will be no permanent storage of ammonia

               at the Commercial Port.     The quantity (420,000 gallons) required to

               initially charge the system can be shipped in bulk via barge, small

               tanker or break-bulk in containers as described in Chapter V.             If

               system    losses   during   plant   operation    prove   to   be    minimal,

               replenishment quantities of the chemical could be shipped thereafter

               in break-bulk.

                                                     12
<pb n="24" />

                     There are no 'local     producers of anhydrous ammonia on Guam.

                Ammonia in the quantities required for OTEC, therefore, must be

                imported via shipping vessels.       Whether the source of the chemical

                is foreign or domestic is immaterial to Commercial Port operations,

                provided     all     Fertinent     U.S.    regulations     governing       the

                transportation, handling and storage of ammonia are met.

                3.2 Properties and Hazards of Ammonia

                     Although   the explosion and fire hazards associated with NH            3
                are limited, the health hazards are serious.         The objective of this

                section is to identify the hazards that will be presented in the

                transportation, handling and storage of this chemical.

                     At atmospheric pressure, liquid ammonia boils at about -280F;

                at a vapor pressure of about 108 psia, it boils at 600F.              Ammonia

                can be in a liquid state when either refrigerated or at ambient

                temperature    depending    upon  storage   pressure.     Ammonia   is    very

                soluble    in  water,   and   the  dissolution    process   is    exothermic.

                Releases of ammonia are harmful for two primary reasons: first, the

                vapor is toxic, and second, a solution of ammonia in water (ammonium

                hydroxide) is deadly to both flora and fauna.

                                                      13
<pb n="25" />

                  The major hazard from an ammonia vapor cloud is its toxicity.

               Ammonia is an extremely irritating gas, even in relatively small

               concentrations.   In  the case of excessive exposure,       deleterious

               reactions from anhydrous ammonia occur      in the upper respiratory

               tract as spasms, inflamation, or edema of the larynx.      Fortunately,

               the human olfactory system is capable of detecting the presence of

               ammonia long before the toxic limit is reached.      These hazards and

               safety precautions are discussed in Chapter IV.

                                                  14
<pb n="26" />

                                                       TABLE 3-1

                                    CHEMICAL AND PHYSICAL PROPERTIES OF AMMONIA

                Chemical Formula                                           NH3

                Molecular Weight                                           17.03

                Boiling Temperature at Atmospheric Pressure, C             -2.22 (-28.0 F)

                Freezing Temperature at Atmospheric Pressure, C            -77.77(-108.0 F)

                Critical Temperature, C                                    1-33.0 (271.4 F)

                Critical Density, lb per cu ft                             14.6

                Density of Liquid at -28.0 F, lb per cu ft                 42.56

                Specific Volume of Saturated Vapor
                  at -28.0 F, cu ft per lb                                 18.00
                Specific' Heat of Liquid at 86 F, Btu per (lb) (F)         1.143

                Color                                                      Clear and
                                                                           water white

                Odor and Detection                                         Irritating, odor, readily
                                                                           detectable by smell.
                                                                           Burning sulphur used for
                                                                           locating leaks.

                Flammability Limits (Per cent by volume)                   15 to 25

                Toxicity, Underwriters' Laboratories Classification        Group 2

                                                      14A
<pb n="27" />

                                              CHAPTER IV

                             HAZARDS AND SAFETY PRECAUTIONS FOR AMMONIA

               4.1 General

                  The hazards of ammonia have been well investigated because of

               its long use     as a refrigerant and         agricultural    fertilizer.

               Anhydrous  ammonia   possesses   the   potential   to   inflict   serious

               personal injury.   A mishap involving ammonia will usually cause the

               victim great pain    and may well blind him if contact with the

               chemical is on the face.

                  Unuer normal atmospheric conditions, anhydrous ammonia in an

               open vessel is always boiling and escaping into the atmosphere.         To

               prevent its escape, the anhydrous ammonia is stored in pressurized

               vessels.   Anhydrous   ammonia weighs    approximately    5  pounds    per

               gallon.   The   weight  per   gallon  varies   with   the  pressure    and

               temperature.   It is stored, transported, and otherwise handled as a

               liquid under pressure in cylinders and tanks. It may also be stored

               under refrigerated conditions.

                   Upon release into the atmosphere, liquid ammonia vaporizes and

               expands rapidly.   As vapor it occupies about 850 times its liquid

               volume.   Liquid ammonia absorbs heat as it vaporizes and expands

               into a gas.    This property makes ammonia useful as a refrigerant.

               Liquid ammonia released suddenly to the atmosphere usually results

                                                   15
<pb n="28" />

               in a white cloud of water vapor, which lasts a short time until

               aispersed by air currents. This cloud is formed by the condensation

               of water vapor in the air surrounding the liquid ammonia.

               4.2 Ammonia Vapor Hazards

                   Ammonia can be released in two fashions.          The first is the

               release of gas or liquid in a continuous emission over a finite

               period of time.    The second is the instantaneous or slug release in

               which the material is released in a very short period of time, as in

               the catastrophic failure of a pressurized container or a pipeline.

                   The failure of a valve or fitting on a container or pipeline

               usually results in a continuous release, and the downwind hazard

               prevails as long as the emission continues. When such a failure is

               associated with a container, the rate of emission will steadily

               decrease as the pressure within the vessel decreases.        The rate of

               emission from pipeline ruptures will depend on the line size,

               pressure, flow rate, line contents (liquid or gas), and the time to

               stop the flow.    The area affected by a gaseous release is dependent

               upon the quantity released, rate of emission, total elapsed time of

               emission, atmospheric conditions and the terrain.

                   Timely evacuation of an area contaminated by an                ammonia

               discharge   may  not   always  be   possible.    Recommended    evacuation

               distances are listed in Table 4-1, based on a prevailing wind of

               6-12 mph.    The safe evacuation distance may not be practical to

                                                   16
<pb n="29" />

                                                 TABLE 4-1

                         EVACUATION TABLE - BASED ON PREVAILING WIND OF 6-12 MPH

             Approximate   Distat,ce to Evacuate         For Maximum Safety
             Size of Spill   From Immediate         Downwind Evacuation
                         Danger Area      Area Should Be

             200 square feet    40 yaras (48 paces) 1,056 feet long, 528 feet

             400 square feet    60 yards (72 paces) 1,584 feet long, 1,056 feet widle

             600 square feet    80 yards (96 paces) 2,112 feet long, 1,056 feet wide

             800 square feet    90 yards (108 paces)      2,112 feet long, 1,584 feet wide

             In the event of an explosion, the minimum safe distance from flying fragments
             is 2,000 feet in all directions.

             Source: Emergency Action Guide for Selected Hazardous Materials, 1978.

                                                16A
<pb n="30" />

              attain.   In such circumstances personnel should remain upwind of

              spills or leaks, if possible, or remain indoors with windows shut

              until the hazard has passed.

              4.3 Personal Protective Equipment

                  Skin, eye or respiratory contact is not likely to occur except

              during nonroutine operations involving accidental release of ammonia

              into the atmosphere.     The American National Standard Institute

              (ANSI) requirements recommend that all storage areas have on hand,

              as a minimum, the following equipment for emergency and rescue

              purposes

                  (1)  One full face mask with anhydrous ammonia refill canisters

                  (2)  One pair of protective gloves

                  (3)  One pair of protective boots

                  (4)  One protective slicker

                  (5)  Easily accessible shower and/or at least 50 gallons of

                       clean water in an open container

                  (6)  Tight-fitting vented goggles or one face shield

                  Gloves, boots, slickers, jackets and pants should be made of

              rubber or other material impervious to ammonia.

                                                17
<pb n="31" />

               4.4 Storage Area Precautions

                   Consideration must be given to the physiological effects of

               ammonia as well as to adjacent fire hazards.      Storage areas must be

               kept free from oxidizers and readily ignitible materials such as

               waste and weeds.

                   Chlorine is incompatible and may react violently with ammonia.

               These materials may not be stored immediately adjacent to each other.

               4.5 Labeling/Posting

                   All shipping containers of ammonia must bear the label shown in

               Figure 4-1 in addition to, or in combination with, labels required

               by other statutes.

                   The  following warning     sign  should be    affixed  in  a readily

               visible location at or near entrances to areas containing anhydrous

               ammon i a and   in   wh i ch there   is   a  reasonable   potential     for

               emergencies. This sign should be printed     both in English and in the

               predominant    languages    of   non-English-speaking     workers.      All

               employees should be trained and informed of the hazardous areas,

               with special instruction given to illiterate workers.

                                                    18
<pb n="32" />

                                            FIGURE 4-1

                                      AMMONIA SHIPPING LABEL

                                        AMMONIA, ANHYDROUS

                                 DANGER! HAZARDOUS LIQUID  AND GAS

                                        LIQUID CAUSES BURNS

                                     GAS EXTREMELY IRRITATING

                                        DO NOT BREATHE GAS

                             DO NOT GET IN EYES, ON SKIN, ON CLOTHING

                            IN CASE OF EXPOSURE, EVACUATE TO FRESH AIR

                               IN CASE OF CONTACT, IMMEDIATELY FLUSH

                               SKIN OR EYES WITH PLENTY OF WATER FOR

                           AT LEAST 15 MINUTES. GET MEDICAL ATTENTION

                              AT ONCE IN CASE OF EYE CONTACT OR BURNS

                     TO THE NOSE OR THROAT, OR IF THE PATIENT IS UNCONSCIOUS.

                                                18A
<pb n="33" />

                                               WARNING!

                                         AMMONIA HAZARD AREA

                                    UNAUTHORIZED PERSONS KEEP OUT

                                   CAUSES BURNS, SEVERE EYE HAZARD

                           INHALATION OF HIGH CONCENTRATIONS MAY BE FATAL
                         GAS MASKS LOCATED AT                              6

               4.6 Fire  Hazard

                  While  not considered to be a serious fire or explosion hazard,

               ammonia will burn or explode under some conditions, such as a large,

               intense source of ignition and a high concentration of ammonia gas.

               The presence of iron appreciably decreases the ignition temperature,

               and the presence of oil or a mixture of ammonia with other flammable

               substances increases the fire hazard. Increasing the oxygen content

               of the air or increasing the temperature and pressure of the ammonia

               broadens  the   flammable   (explosive)  range.    Contact   with    other

               chemicals such as mercury, silver oxide, iodine, chlorine halogens,

               calcium, and hypochlorite can cause spontaneous explosions due to

               chemical reactions.

               4.7 Leak Hazard

                   A leak   in an ammonia system can be detected by odor.             The

               location of the leak may be determined with moist phenolphthalein or

               red litmus paper which change color in an ammonia vapor.           Another

                                                   19
<pb n="34" />

                means of detection is the use of sulfur dioxide, which forms a white

                fog in contact with ammonia vapor.

                    Only personnel trained for and designated to handle emergencies

                should attempt to stop a leak.         Respiratory equipment of a type

                suitable for ammon'a must be worn. All persons not so equipped must

                leave the affected area until the leak has been stopped.

                    If ammonia vapor is released, the irritating effect of the vapor

                will force personnel to leave the area long before they have been

                exposed to dangerous concentrations.          With good ventilation or

                rapidly moving air currents, ammonia-vapor,      being lighter than air,

                can be expected to dissipate readily without further action being

                necessary.

                4.8 Health Hazards

                    4.8.1 Warning Properties

                          At atmospheric temperatures and presures, ammonia is a

                    pungent and colorless gas and serves as its own warning agent;

                    special    detection meters are not necessary to determine

                    dangerous   concentrations of ammonia vapor.      The human nose will

                    detect ammonia vapor in concentrations far below the injurious

                    level.    The odor is so uncomfortable that personnel will not

                                                     20
<pb n="35" />

                    voluntarily remain exposed to injurious concentrations.           Table

                    4-2  shows   the   general   physiological    effects   of    selected

                    concentrations of ammonia.

                    4.8.2 Severe Exposure

                         There  are a number of well       documented cases of severe
                    exposure to ammoniaJ 7 1     The severity of the symptoms is, of

                    course, a function of the degree of exposure.          Some symptoms

                    which may be expected if exposure is severe are irritation to

                    inflammatory   processes    of   the   entire    respiratory     tract,

                    pulmanary edema, bronchopneumonia, acute skin burns, and eye

                    injury among others.

                    4.8.3 Exposure Countermeasures

                         4.8.3 (a) Inhalation

                               Exposed persons must be removed at once to an uncontaminated

                         area.    If the exposure has been to minor concentrations for a

                         limited time, usually no treatment will be required.

                               When there is severe exposure to higher concentrations, and

                         if oxygen apparatus is available, oxygen can be administered but

                         only by a person authorized by a physician. If the patient is not

                         breathing, an effective means of artificial respiration must be

                         initiated immediately. Call a physician.

                                                     21
<pb n="36" />

                                                      TABLE 4-2

                                          PHYSIOLOGICAL EFFECTS OF AMMONIA

                    CONCENTRATION
                    NH3 VAPOR      PERCENT       GENERAL EFFECT           EXPOSURE PERIOD
                       (PPM)

                      50              11200        Odor detectable          Prolonged, repeated
                                                   by most persons.         exposure produces no
                                                                            injury.

                      100             1/100        No adverse affects       Maximum allowable
                                                   for average person       concentration for
                                                                            8-hour working
                                                                            exposure.

                      400             4/100        Nose and throat          Infrequent short
                                       to          irritation. Eye          (I hour) exposures
                                      71100        irritation with          ordinarily produce
                                                   tearing.                 no serious effect.

                      2,000           2110         Convulsive cough-        No permissible
                        to             to          ing; severe eye          exposure. May be
                      3,000           3/10         irritation.              fatal after short
                                                                            exposure.

                      5,000           112          Respiratory  spasm.      No exposure permis-
                        to            to           Rapid asphyxia.          sible. Rapidly fatal.
                      10,000           1

                      Source: Operational Safety Manual for Anhydrous Ammonia

                                                    21A
<pb n="37" />

                              The patient should be kept comfortably warm but not too hot

                         and kept at rest.    Never attempt to give anything by mouth to an

                         unconscious patient.

                         4.8.3 (b) Taken Internally

                              If liquid anhydrous ammonia has been swallowed, call a

                         physician immediately.     If the patient is conscious and able, he

                         should    drink    large    amounts    of    water    to    dilute     the

                         chemical.   Do not induce vomiting if the patient is in

                         shock, extreme pain or unconscious.        If vomiting begins,

                         place the patient face down with head lower than hips.

                         This prevents vomitus from entering the lungs and causing
                         further injuryJ 8

                         4.8.3 (c) Contact With The Eyes

                              While respiratory injuries may be lethal           and skin

                         burns disfiguring, eye injuries constitute the most serious

                         hazard in regard to permanent disability.        Ammonia is one

                         of the most damaging substances affecting the eyes.

                         Ammonia is fat-soluble but the key to its rapid penetration

                         is its extreme solubility in water and its destructiveness

                         in an alkaline solution.      Because of the rapid penetration

                         of ammonia, even prompt flushing will not remove all of the

                         chemical. Although complete elimination of the chemical is

                                                    22
<pb n="38" />

                         hopeless,  the degree of     injury varies with duration of

                         exposure; rapid, copious flushing is essential to limiting

                         damage.

                         4.8.3 (d) Contact With Skin and Mucous Membranes

                              Speed in removing ammonia from contact with the

                         patient and in moving the patient to an uncontaminated

                         atmosphere is of primary importance.       If skin contact is

                         extensive and emergency showers available the employee

                         should get under the shower.     Flushing with large amounts

                         of running water should be continued for at least 15

                         minutes.

                              Under no condition should salves or ointments be

                         applied to the skin or mucous membrane burns during the

                         24-hour period following the injury.        Subsequent medical

                         treatment is otherwise the same as for thermal burns.

                   4.8.4 Procedures For Obtaining Medical Assistance

                         Procedures specified below should be formulated in advance

                   and   employees   should   be  instructed   and   drilled   in   their

                   implementation.     Procedures    should   include    assignment    of

                   individual and/or team responsibilities and pre-arranged plans

                   for:

                                                   23,
<pb n="39" />

                         Immediate evacuation of workers with signs or symptoms of

                         adverse effects resulting from exposure.

                   2.    Transportation of injured persons to medical facilities.

                   3.    Any neces-lary calls to alert medical facilities of the

                         impending arrival of injurea persons.

                   4.    Designation of medical receiving facilities and names of

                         physicians-   trained    in   anhydrous    ammonia     emergency

                         procedures.

                   4.8.5 Suggestions to Physicians

                         There is no specific treatment for over-exposure or direct

                   local contact to anhydrous ammonia vapors.          Oxygen has been

                   found useful in the treatment of inhalation exposures of many

                   chemicals, especially those capable of causing either immediate
                   or delayed harmful effects in the lungs.19 I

                         In most exposures, administration of 100% oxygen at

                   atmospheric pressures has been found to be adequate.          This is

                   best accomplished by use of a face mask with a reservoir bag of

                   the non-rebreathing   type.    Inhalation of 100% oxygen should not

                   exceed one hour of continuous treatment.            After each hour

                   therapy may be interrupted;      and it may be reinstituted as the
                   clinical condition indicates.1101

                                                    24
<pb n="40" />

                         Some believe that superior results are obtained when

                   exposures to lung irritants are treated with oxygen under an
                   exhalation   pressure   not   exceeding   4  cm   water.1111     Masks

                   providing for such exhalation pressures are obtainable.              A

                   single treatment may suffice for minor exposures to irritants.

                   It is believed by some observers that oxygen under pressure is

                   useful as an aid in the prevention of pulmonary edema after

                   breathing irritants.

                         Caution:   It may not be advisable to administer oxygen

                   under positive pressure in the presence of impending or existing

                   cardiovascular failure.

               4.9 Personnel Safety Training

                   4.9.1 Informing Employees    of Hazards of Ammonia

                        At the beginning of employment, workers whose jobs may

                   involve exposure to ammonia should be informed of the hazards,

                   relevant    symptoms   of   overexposure,    appropriate     emergency

                   procedures, and precautions to ensure safe use and to minimize

                   exposure.    First aid procedures should be included, with

                   emphasis on the importance of prompt, copious irrigation of the

                   eyes despite the initial lack of pain.      The information must be

                   posted in the workplace and kept on file, readily accessible to

                   workers at all places of employment where ammonia is involved.

                                                   25
<pb n="41" />

                         A continuing educational program, conducted by a person or

                   persons qualified by reason of experience or special training,

                   must be    instituted to ensure that all        workers have current

                   knowledge of job      hazards, first-aid procedures, maintenance

                   procedures and clean up methods, and that they know how to use

                   respiratory    protective    equipment    and   protective     clothing.

                   Retraining should be repeated at least annually.

                   4.9.2 Training and Drills

                         Members of emergency teams and employees who will work

                         adjacent   to   ammonia    systems   where    a   potential     for

                         emergencies due to ammonia exists should be subjected to

                         periodic drills simulating emergency situations appropriate

                         to the work situation.      These should be held at intervals

                         not exceeding 6 months.      Drills should cover, but not be

                         limited to, the following:

                         1.   Evacuation procedures;

                         2.   Handling      of     spills     and     leaks,       including

                              decontamination and use of emergency repair kits;

                         3.   Location and use of emergency firefighting equipment;

                         4.   Handling of containers in case of fire;

                         5.   First    aid   and   rescue,    including   procedures     for

                              obtaining medical care;

                                                     26
<pb n="42" />

                       6.  Location, use, and care of protective clothing and

                           respiratory equipment;

                       7.  Location and use of shut-off valves;

                       8.  Location, reason for, and use of safety showers,

                           eyewash fountains, and other sources of water for

                           emercency use;

                       9.  Operating procedures;

                       10. Entry procedures for confined spaces; and

                       11. Emergency phone numbers.

                                               27
<pb n="43" />

                                           CHAPTER V

                                   TRANSPORTATION OF AMMONIA

                 Anhydrous ammonia  can be imported to Guam in bulk, break-bulk,

             or a combination of both.   The final decision on shipping mode will

             aepend upon the rpsults of a detailed cost analysis.         Such   an

             analysis is beyond the scope of this present work.     In this study

             the influence on Commercial Port operations during receipt and

             handling of both bulk and break-bulk shipments are discussed.

             5.1 Containerized Break-Bulk Shipment

                 Break-bulk shipment of ammonia is shipment in tanks mounted on

             the chassis of open hopper containers.     Tanks transported in this

             manner are handled in the same fashion as other containerized cargo

             and require no equipment not presently available at the Port.      The

             Commercial Port is primarily a containerized operation now, with 85%

             of the general cargo being containerized.

                 In a typical unloading scenario, the containers are removed from

             the ship by gantry crane, placed on a chassis and taken directly to

             the plant site.   In the event that the containers cannot be taken

             directly to the plant site because of either insufficient chassis or

             storage space at the OTEC plant, the Commercial Port container yard

             space will have to be reserved.     The current Master Plan for the

             Commercial Port recommends expansion of the existing container yard

                                               28
<pb n="44" />

                facilities.   A temporary storage area must be designated prior to

                delivery of a container shipment in event that immediate transfer to

                the OTEC plant is delayed.     It is anticipated that adequate storage

                space will be available at the OTEC plant site for containers.

                    Portable tanks should be removed from the Commercial Port as

                soon as possible. If temporary storage is necessary, the tanks must

                be kept away from sources of heat, including direct sunlight, that

                could increase the ammonia gas pressure,          activating the relief

                valve.   Care must be taken to prevent mechanical damage to the

                container and its appurtenances.

                    An accident involving a motar vehicle transporting a portable

                tank can create a serious hazard.         Only persons engaged in the

                removal of such a hazard and wreckage should be allowed near the

                accident scene.      The rescue and salvage operation should be

                supervised by competent personnel experienced in han       dling ammonia.

                Telephone notice of ammonia related accidents must be given by the

                carrier to the DOT and followed with a written report.                These

                requirements are covered by 49 CFR 171.15,           171.16,  177.854 and

                177.859. Motor vehicle requirements are discussed in section 5.2.2.

                    The hazardous chemical transfer route from the Commercial Port

                to the OTEC plant is uninhabited with no intersections or transit

                trafic.   The route is approximately one mile from the Port to the

                OTEC plant. (Figure 2-2)

                                                     29
<pb n="45" />

                   Portable tanks used for transportation of ammonia must comply
              with current DOT specifications.L121       This is of concern if the

              ammonia is procured from a foreign source.     These tanks are designed

              to be temporarily attached to a motor vehicle and equipped with

              skids, mountings or accessories to facilitate handling of the tank

              by mechanical means.

              5.2 Bulk Shipment

                   Anhydrous ammonia can be shipped in bulk quantities via barge or

              small tanker.   The quantity of ammonia initially required is about

              420,000 gallons.     Two viable options for transshipment of the

              chemical from the port to the OTEC plant site are pipeline or tank

              truck.

                   5.2.1 Ammonia Pipeline

                        Should  a   pipeline  be   installed  for   transportation   of

                   anhydrous ammonia from the port to the OTEC plant, the most

                   probable location for the receiving manifold would be in the

                   area of Wharf F-6, as depicted on Figure 2-2.

                        The F-6 location at the east end of the Commercial Port, is

                   close to the proposed OTEC plant site and offers the least

                   interference with other berthing areas and container yard

                   activities.   In addition, the distance from Wharf F-6 to the

                                                  30
<pb n="46" />

                      Commercial Port office complex is approximately 2,000 feet and

                      offers maximum downwind safety in event of a hazardous chemical

                      spill or leak.

                           0ther potential receiving areas for, bulk ammonia shipments

                      are  the -Mobil, GORCO and Navy fuel piers.            Each of these
                      facilities are a greater distance than F-6 to 'the proposed OTEC

                      plant site and offer no advantage over the Commercial Port

                      location. The existing oil pipelines at these facilities cannot

                      be used for ammonia transfer.

                           A fixed piping system       from the Commercial Port to the

                      proposed OTEC' plant site will be about one mile in length.

                      Fixed piping, either surface or underground, will require a

                      considerable investment.     The system can be expected to be idle

                      for long periods of time while incurring maintenance costs. Due

                      to the high concentration of salt spray on Cabras                Island,

                      pipeline maintenance costs are high.         An aboveground pipeline

                      would be subject to vehicle collisions and will require periodic

                      painting,   leak   tests,    and  cathodic   protection   among    other

                      procedures.    Both aboveground and underground pipelines are

                      subject to earthquake damage.

                           A thorough engineering study of an ammonia pipeline is

                      required before a final       decision;   the pipeline may require

                      unconventional equipment design and pressure ratings to solve
                      potential problems.

                                                       31
<pb n="47" />

                   5.2.1 (a) Pipeline Leaks

                        The problem of potential leaks is present in any pipeline.

                   Consequences of a leak and means of minimizing or handling leaks

                   must be considered in the early stages of design.

                        Leaks   in  ammonia handling    equipment   must   be   repaired

                   immediately.    Some repairs are simple:       valve packing gland

                   leaks may require only tightening of the nut.        Other repairs,

                   however, require that all ammonia be purged from the system

                   before attempting to dismantle or repair it.       All repairs must

                   be made in compliance with the code under which the pipe is

                   fabricated. Only code welding is permitted on pressure vessels,

                   after completely purging the line with nitrogen or water.

                        The presence of ammonia leaks is ordinarily obvious from

                   scent; the nose detects ammonia fumes in minute quantities.

                   Locating leaks, however, will often require special equipment

                   and procedures.    One method of testing uses moistened strips of

                   red litmus paper which turn blue in the presence of ammonia;

                   another uses sulfer dioxide, which forms a white fog in contact

                   with ammonia vapor.

                                                   32
<pb n="48" />

                    b.2.1 (b)  kouting

                         Special care must be given to design criteria for long

                    pipelines due to the amount of ammonia which they may contain.

                    Also, the potential liability to the owner and/or operator of a

                    pipeline in event of leaks must be considered. Any above ground

                    line is subject to the hazards of fire;        the route should be

                    cleared of grass, brush, and other combustible materials.

                    5.2.1 (c) Government Regulations

                         Code of Federal Regulations, Title 49, Chapter 1, Parts

                    190-192 and 195 govern the transportation of gas by pipeline;

                    subparts    included   cover     "Accident    Reporting",     "Design

                    Requirements", "Construction", and "Operation and Maintenance".

                    5.2.1 (d) Design

                         Moist ammonia corrodes copper, zinc and their alloys. Iron

                    and steel are, therefore, ordinarily used in            piping and

                    fittings.   Extra heavy steel (Schedule 80) is preferable for

                    ammonia pipeline and welded, not threaded, joints must be used.

                    Only all steel pressure gages must be used.        Furthermore, any

                    pumps or compressors used for ammonia must be expressly

                    recommended and labeled for that purpose by the manufacturer.

                    Buried pipelines must be protected by a suitable cathodic

                    protection system.

                                                   33
<pb n="49" />

                  5.2.1 (e) Installation

                       Pipelines may be installed above or below ground.           The

                  entire system  should be evaluated to determine the preferred

                  installation.   For monitoring purposes, the above ground system

                  is preferred.   An above ground installation must be designed so

                  as to preclude damage by vehicles.

                       If an ammonia ]in  e is run in a pipe rack where it shares

                  space with other pipelines carrying flammable materials, the

                  ammonia line should be protected from fire resulting from a leak

                  or break in one of the other lines.        Such protection can be

                  achieved through:    (1), adequate physical     separation of the

                  line; (2), erection   of a steel barrier between lines; or (3),

                  proper insulation of  the line with a fire-resistant material.

                       Above ground or buried pipelines must be suitably marked at

                  intervals of not over 200 feet.        Permanent metal signs are

                  recommended.    Recommended   wording   for   liquid   lines   is:

                  "Liquified Gas Under Pressure--Ammonia".     In addition, the name

                  and telephone number of the operator must be shown.

                                                 34
<pb n="50" />

                   5.2.2 Tank Trucks

                        A barge or small tanker could unload ammonia into tank

                   trucks designed specifically for   that chemical.    The maximum

                   tank capacity is restricted by      highway weight load limits

                   (76,000 lbs.).    Two 8,000 gallon capacity tank trucks can

                   transfer 420,000 gallons of ammonia from a barge or small tanker

                   to the proposed OTEC plant site in  approximately 30 hours.    The

                   U.S. Coast Guard has required minor improvements to Route 11

                   prior to authorizing transshipment of explosives by truck.

                   maintenance and repair work (fixing pot holes, soft shoulders

                   etc.) can be required prior to transshipment if deemed necess,ary

                   by the Coast Guard.

                   5.2.2 (a) Trailers  and Semitrailer Requirements

                        Trailers must  be  firmly and securely attached to their

                   tractors by means of suitable drawbars, supplemented by suitable

                   safety chain or safety cables.

                        Every trailer or semi-trailer must be equipped wit     h a  n

                   emergency braking system to be activated in the event of a hitch

                   failure.

                                                 35
<pb n="51" />

                   5.2.2 (b) Protection Against Collision

                        Each tank motor vehicle must be provided with properly

                   attached bumpers or chassis extensions       to protect the tank,

                   piping, valves and fittings from physical damage in case of

                   minor collision.

                   5.2.2 (c) Safety Equipment

                        All tank trucks, trailers and semi-trailers must be

                   equipped with the following equipment for emergency and rescue
                   purposes:[13]

                   One full face mask with anhydrous ammonia refill canisters.

                   One pair of protective gloves made of rubber or other material

                   impervious to ammonia.

                   Tight-fitting goggles or one full face shield.

                   A container of not less than five gallons of readily available

                   clean water.

                   Additionally,    special     markings    indicating    the     special

                   characteristics of the ammonia cargo must be displayed on the

                   vehicle in accordance with Title 49, Code of Federal Regulations.

                                                   36
<pb n="52" />

                                               CHAPTER VI

                                 QUANTITIES AND PROPERTIES OF CHLORINE

                6.1 Required Quantities and Importation of C12

                    A chlorination system is provided in plant design        to control

                biofouling of heat transfer and hydraulic systems.        Prevention of

                biofouling is an important consideration for maximizing heat

                transfer rates.    Biofouling is caused by development and deposition

                of micro-organisms and marine growth on surfaces in contact with

                seawater.   Although chlorination has been selected as the primary

                method   to  control   biofouling,   a   supplemental   system   may    be

                incorporated if data at the time of installation indicates that
                chlorination is not sufficient to control biofouling.[141

                    Chlorine can be generated on-site, in the form of hypochlorite,

                by passing a direct current through seawater:

                         Na Cl + H20 + Electric Current ==&gt; NaOCl + H2

                The chlorine dosage is expected to be 0.25 ppm into the evaporator
                seawater and 0.1 ppm into condenser seawater.[151       This amounts to
                approximately 11,700 lbs. of chlorine per day.[1611171           Although

                not specifically stated in the preliminary design studies, the plant

                is expected to be able to produce its total daily chlorine needs

                while in operation.

                                                    37
<pb n="53" />

                  The total cost and effectiveness of alternate fouling control

              methods will    ultimately determine the system chosen to,7Qontrol
              biofouling.   These costs include capital, installation, operating,

              maintenance, and parasitic power requirements.           Chlorine can be

              added in the   form of gaseous chlorine, concentrated hypochloride or

              on-site electrolytically generated dilute hypochlorite.        The latter

              method of on-site generation is preferred at present for reasons of

              cost, safety and equipment availability.

                   Effective biofouling control will be required from the first day
              of    flooding  the   system.1181     In  addition,   yearly maintenance

              schedules will require plant shutdown for approximately two weeks.

              During   these   periods   on-site   generated   chlorine   will   not    be

              available.   Therefore, for the purposes of Commercial Port planning,

              limited importation of chlorine should be assumed.

              6.2 Properties and Hazards of Chlorine

                   The  properties    of chlorine    (in  the   form of     hypochlorite)

              applicable to OTEC are its effectiveness in deterring marine

              biofouling.     In addition this chemical can be electrolytically

              generated     on-site    realizing     savings    in    procurement      and

              transportation.

                                                    38
<pb n="54" />

                    Chlorine is a chemical element.       Neither its gas nor liquid

                state is explosive or flammable; however, both react chemically with

                many substances.   Chlorine is only slightly soluble in water.        The

                gas has a characteristic odor and greenish yellow color and is about

                two and one-half times as heavy as air.     Thus, if it escapes from a

                container or system, it will seek the lowest adjacent level. Liquid

                chlorine  is  transparent,   amber  in color and     is  about one and

                one-half times as heavy as water. At atmospheric pressure, it boils
                at about  150OF and freezes at about -300F.       One volume of liquid

                chlorine, when vaporized, will yield about 460 volumes of gas.

                Chlorine is very reactive when moisture is present.

                    Chlorine is classified as nonflammable and nonexplosive.          The

                major hazard associated with chlorine is toxicity.         Some symtoms

                from severe exposure are pulmanary congestion, difficult or labored

                breathing, burning of the eyes, throat, skin or nasal passages,

                choking, nausea, and vomiting.      Hazards and safety considerations

                associated with Cl 2 are discussed in Chapter VII.

                                                   39
<pb n="55" />

                                                   TABLE 6-1

                                 CHEMICAL AND PHYSICAL PROPERTIES OF CHLORINE

              Molecular weight                                         70.906 g/mole

              Vapor pressure, 21 C                                     6.0 kg/sq cm gage
                                                                         (85.3 psig)

              Specific volume, 21 C, I atm                             0.34 liters/g

              Boiling point, I atm                                     -34 C

              Freezing point (bp), I atm                               -101 C

              Specific gravity of gas at  0 C,
                I atm (air = 1)                                        2.49

              Specific gravity  of liquid at 20 C                      1.41

              Density of gas at 0 C, I atin                            3.214 g/liter

              Density of liquid at 0 C, 3.65 atm                       1468 g/liter

              Critical temperature                                     144 C

              Critical pressure                                        78.64 kg/sq cm
                                                                         absolute (76.1 atm)

              Latent heat of vaporization at bp                        68.8 calories/g

              Solubility in water at 20 C, I atm                       7.30 g/liter

              Color of gas                                             Yellowish green

              Color, of liquid                                         Clear amber

              Flammability                                             Nonflammable

              Reactivity                                               Highly reactive

              Odor                                                     Disagreeable, strong,
                                                                         suffocating, pungent,
                                                                         irritating,
                                                                         characteristic

                                                  39A
<pb n="56" />

                                                CHAPTER VII

                               HAZARDS AND SAFETY PRECAUTIONS FOR CHLORINE

                7.1  General

                    Chlorine gas is primarily a h@azardous respiratory irritant.           It

                is so intensely irritating that very low concentrations in the air

                are readily detectable.        In higher concentrations the severely

                irritating effect of the gas makes it unlikely that any person would

                remain   in   a   chlorine   contaminated    atmosphere    unless    he    is

                unconscious or trapped.

                    When a sufficient concentration of chlorine gas is present, it

                will irritate the mucous membranes, the respiratory system and the

                skin.  Large amounts cause irritation of eyes, coughing and labored

                breathing.    If the duration of exposure or the concentration of

                chlorine is excessive, general excitement of the person affected

                results, accompanied by restlessness, throat irritation, sneezing

                and copious salivation.      Additional symptoms of exposure to high

                concentrations are retching and vomiting, followed by difficult

                breathing.    In extreme cases, the difficulty of breathing may

                increase to the point where death can occur from suffocation.

                                                     40
<pb n="57" />

                7.2 Chlorine Vapor Hazards

                   A hazardous chemical can be released in two fashions. the first

                is the release of gas or liquid in a continuous emission over a

                finite peri,od, of time.   The second is the instantaneous or slug

                release in which t.ie material is released in a very short period of

                time, as in the failure of a pressurized container.

                    The failure of a valve or fitting on a container usually results

                in a continuous release, and the downwind hazard continues as long

                as the emission continues. When such a failure is associated with a

                container,  the rate of emission will       steadily decrease as the

                pressure within the vessel decreases.        The area affected by -@a

                gaseous release is dependent upon the quantity released, the rate of

                emission, the total elapsed time of emission, the atmospheric

                conditions and the terrain.

                    The  timely   evacuation   of  a  contaminated   area by    chlorine

                discharge may not always be possible.          Furthermore, the safe

                evacuation distance may not always be practical to attain.      In such

                circumstances, personnel should remain upwind of spills or cleaks if

                possible or remain indoors until the hazard has elapsed,.

                                                   41
<pb n="58" />

                 7.3  Personal Protective Equipment

                     Normal work clothing will provide all the protection that is

                 required for the period of time it takes to escape from an

                 emergency.   Skin, eye or respiratory contact is not likely to occur

                 except during nonr3utine operations involving accidental release of

                 chlorine into the dtmosphere.      Protective clothing should never be

                 required under routine operating conditions.         When an emergency

                 occurs, the personnel in the area would be expected to escape from

                 the hazard without special protective clothing.

                     Possible   exposure   to   chlorine   gas  in   the  performance     of

                 essential duties ot rescue, fire and emergency repair crews will

                 necessitate availability of rubber clothing, including boots and

                 hoods in combination with some form of life support system.           When

                 such is used, it is essential that it be used by persons who have

                 been specifically and recently trained in the use and limitations of

                 such equipment.

                 7.4 Storage Area Precautions

                     Chlorine should be stored in adequately ventilated unoccupied

                 warehouses or outdoors shielded from the direct rays of the sun,

                 unless the containers are properly insulated and designed for

                 unshaded outdoor storage.       Consideration must be given to the

                                                     42
<pb n="59" />

               physiological effects of chlorine as well as to adjacent fire

               hazards. Storage areas must be kept free from oxidizers and readily

               ignitable materials such as waste and weeds.

                   Gaseous chlorine is about 2.5 times            as heavy as air.119 I

               Therefore, in the absence of air currents, leaking chlorine tends to

               accumulate in low spots. Storage areas must be planned and occupied

               with this chlorine property in mind.

                   If indoor storage areas are utilized, at least two exits, remote

               from each other and opening outward of the building, must be

               provided for all chlorine storage rooms.

                   Chlorine is incompatible and may react violently with ammonia.

               These materials may not be stored immediately adjacent to each

               other.   It is not anticipated that chlorine will be stored at the

               Commercial    Port   for   any   significant    length   of   time.     Other

               incompatible materials which can react violently         with chlorine are

               hydrogen,     acetylene,    fuel     gases,    ether,    turpentine,      most

               hydrocarbons, finely divided metals and organic matter.                  These

               materials must not be stored immediately adjacent to chlorine.             The

               degree of separation required will be dictated by quantities stored

               and the type of storage facility.

                   Containers of chlorine should be used on a first-in-first-out

               (FIFO) basis because valve packings may harden during prolonged

               storage and cause leaks when containers are finally used.

                                                     43
<pb n="60" />

               7.5 Labeling/Posting

                   All  shipping containers of chlorine must bear the following

               label shown in Figure 7-1 or in combination with, labels required by
               other statutes.[20J

                   The warning sign should be affixed in a readily visible location

               at or near entrances to areas in which chlorine is present          in

               containers or systems.  This sign should be printed both in English

               and in the predominant languages of non-English-speaking workers.

               All employees must be trained and informed of the hazardous areas,

               with special instruction given to illiterate workers.

               7.6 Container Handling Procedures

                   It is   illegal to ship a leaking chlorine container or one

               partially or fully loaded which has been exposed to fire. The Coast

               Guard and the manufacturer must be consulted for advice under such
               circumstances.[21]

                   If a ton container or its valves are found out of order, the

               nearest distributor from whom the chlorine was purchased must be

               notified, giving the container number and the nature of the damage.

               Containers are carefully inspected before shipping, but rough

               handling in transit may damage containers and their valves.

                                                 44
<pb n="61" />

                                           FIGURE 7-1

                                    CHLORINE SHIPPING LABEL

                                            CHLORINE

                        DANGER! HAZARDOUS GAS OR LIQUID UNDER PRESSURE

                                      EXTREMELY IRRITATING

                                    MAY BE FATAL IF INHALED

                                          CAUSES BURNS

                                        SEVERE EYE HAZARD

                      Do not breathe gas; use only with adequate

                      ventilation. In case of inhalation, remove to

                      uncontaminated atmosphere, get medical attention

                      immediately. If breathing has stopped, start

                      artificial respiration. Do not get in eyes, on

                      skin, or on clothing. In case of contact,

                      immediately flush skin or eyes with plenty of water

                      for a least 15 minutes, and get medical attention

                      immediately.

                                               44A
<pb n="62" />

                    A I Ichlorine containers must be handled with extreme care.

               Containers cannot be allowed      to drop or strike any object with

               force.   Heat should never be applied to containers or their valves.

                    Containers or their valves should never be altered or repaired.

                    Leaks around valve stems can usually be corrected by tightening

               the packing nut in a clockwise direction.       All threads on chlorine

               valves are right hand threads.

                    Containers should never be presumed to be empty and therefore

               non hazardous.

               7.7 Trailer and Semitrailer Requirements

                    Every trailer or semi-trailer must be equipped with an emergency

               braking system to be activated in event of a hitch failure.

                    Each tank motor vehicle must be provided with properly attached

               bumpers or chassis extensions arranged to protect the tank, piping,

               valves and fittings from physical damage in case of minor collision.

                    DOT regulations specify that as a minimum a gas mask approved

               for chlorine must be on each chlorine motor vehicle. Although these

               regulations pertain to tank trucks specifically designed for that

               chemical,    compliance   with   the   regulation   for   trailers     and

               semitrailers would be advisable for obvious safety reasons.

                                                   45
<pb n="63" />

                7.8 Fire Hazard

                    Chlorine    is   classified    as   nonf I ammab 1 e and    nonexplosive.
                However,   it will    support combustion of certain materials[221             5

                reacting explosively in some cases.         At elevated temperatures, it

                reacts vigorously with most metals.           Carbon steel, for example,
                ignites in an atmosphere of chlorine at (250QC) 4830F.                 It is

                important that precautionary measures be taken to prevent chlorine

                from coming into contact with materials with which it may react.

                    In case of fire, chlorine containers must be removed to a safe

                place or cooled with water if leaks do not exist.              Water cooling

                must not be used at chlorine leaks because the water forms

                hydrochloric acid and accelerates corrosion, enlarging the leak.
                Fusible plugs in chlorine containers melt at 158-1640F, every

                effort should be made to prevent containers from reaching this

                temperature.

                    The    Chlorine    Institute   recommends    that:     (1)   firefighters

                approach chlorine emergencies from an upwind direction while wearing

                full    protective     clothing    including     self-contained      breathing

                apparatus, (2) only personnel      required to remedy the problem should

                enter the contaminated area;        (3) for safety, firefighters should

                work in pairs; and (4) as an       added precaution a lifeline should be

                attached to each firefighter.

                                                      46
<pb n="64" />

                7.9 Leak Hazard

                     As soon as the presence of chlorine in the air becomes apparent,

                the condition must be      corrected.    Chlorine leaks rapidly become

                worse if not corrected immediately.

                    When a chlorin,-:@ leak is discovered, all persons should stay

                upwind of the leak and at a higher level.          Only trained personnel

                equipped with gas masks should be perm       itted to attempt repairs on

                leaking chlorine equipment.      All persons. not properly equipped with

                gas   masks    must   be   prohibited    from   the   contaminated      area.

                Nonessential employees should be evacuated from exposure areas

                during emergencies.     Perimeters of areas of hazardous' exposure must

                be delineated, posted and secured.            Only personnel who have

                appropriate training and who are adequately protected against the

                attendant hazards should take appropriate control action: e.g. leak

                isolation and repair, cleanup of spills, etc.

                     If a chlorine container is leaking, it should be shifted so that

                gaseous rather than liquid chlorine will escape.           A much    smaller

                amount of chlorine will be dissipated into the atmosphere if         gaseous

                rather than liquid chlorine is leaking.           The removal of     gaseous

                chlorine from a container tends to lower the temperature of the

                remaining chlorine, consequently, the pressure in the container is

                reduced.

                                                      47
<pb n="65" />

                   Chlorine leaks can be conveniently located by holding an open

               bottle of strong aqueous ammonia near the suspected area, preferably

               at a slightly lower level.   The formation of dense white fumes will

               indicate the point of leakage.

                   Standardized kits for control of leaks are available.            The

               Chlorine Insitute maintains current listings 9f the locations of
               these kits.[231    The Chlorine Institute should be contacted for

               the nearest location if emergency kits are not available locally.

               These kits operate on the principle of capping off leaking valves or

               sealing off a rupture in the side wall.          It should be noted,

               however, that the use of leak kits requires some training prior to

               use in an emergency situation.

                   Studies by the Bureau of Mines[24] indicate that pinhole leaks

               in chlorine containers are rapidly enlarged by corrosion if moisture

               is present. Furthermore, the control of chlorine leaks or spills by

               the use of water is not effective because of the limited solubility

               of chlorine in water. Even the coldest water will supply sufficient

               heat to cause an increase in the evaporation rate of chlorine.

               Therefore, water must never be used on leaking containers of

               chlorine or to control spills.

                   A safe method of absorbing the contents of leaking chlorine

               cylinders or ton containers should be provided.           Caustic soda

               solutions   furnish   a convenient and cheap means of chlorine

                                                  48
<pb n="66" />

                disposal. Suitable containers and sufficient caustic soda to absorb

                the contents of at least one full container should be available if

                chlorine is to be stored at the Commercial Port.

                7.10 Health Hazards

                    7.10 (a) Warning Properties

                         The readily identifiable odor of chlorine and the attendant

                    disagreeable reactions are the most common means by which

                    workers are warned of impending excessive exposure.          However,

                    determinations of the threshold of odor have given varying

                    results.   The variation of these results probably reflects

                    differences    in   methods   of   determination,    and     possibly
                    differences in the development of odor adaptation.[25]          While

                    a  noticeable   odor  of   chlorine may    indicate  a    potentially

                    hazardous exposure, it should not be relied on as a quantitative

                    indication.

                    7.10 (b) Severe Exposures

                         The dramatic response to substantial exposure is well

                    documented.   Chlorine was used as a war gas during WWI and a

                    number of industrial accidents have been carefully recorded.

                    The severity of the symptoms is, of course, a function of the

                    degree of exposure.    Some symtoms of severe exposure are severe

                                                   49
<pb n="67" />

                    pulmonary congestion, difficult or labored breathing, burning of

                    the eyes, throat, or nasal passages, choking, nausea, vomiting,

                    anxiety and brief loss of consciousness.

                    7.10 (c) Exposure Countermeasures

                          7.10 (c)(1) General

                              Prompt treatment is essential. Immediately remove the

                          patient to an uncontaminated area.       Liquid chlorine and

                          chlorinated water destroy clothing; and if such clothing is

                          next to the skin it will cause irritation and acid burns.

                          In such cases, remove contaminated clothing and wash

                          contaminated body parts.

                          7.10 (c)(2) Gas Inhalation

                               If   breathing    has    ceased,    commence     artificial

                          respiration immediately and administer oxygen as soon as

                          possible.   If breathing has not ceased, place the patient

                          in a comfortable position and administer oxygen as soon as

                          possible.  Keep the patient warm, at rest and render other

                          necessary first aid.

                               A carbon dioxide and oxygen mixture, not to exceed

                          seven percent of carbon dioxide, can be given.              This

                          mixture, ready prepared and sold with            the necessary

                                                    50
<pb n="68" />

                         apparatus, can be administered intermittently for periods

                         of two minutes followed by two-minute rest periods over a

                         total period not to exceed thirty minutes.     Instructions of

                         the purveyor of the gas apparatus should be carefully

                         obeyed.    If carbon dioxide and oxygen mixture is not
                         readily available, oxygen alone can be used.[26][271

                         7.10 (c)(3) Chlorine Eye Contact

                              Flush the eyes immediately with copious amounts of

                         running water for 15 minutes. The eyelids must be forcibly

                         held open to ensure complete irrigation of all eye and lid

                         tissues.  Chemical neutralization of any kind should not be

                         attempted.

                         7.10 (c)(4) Chlorine Skin Contact

                              Wash well with copious amounts of soap and water.

                         Greases or salves should not be applied unless ordered by a

                         physician.

                    7.10 (d) Procedures For Obtaining Medical Assistance

                         The following procedures should be formulated in advance

                    and  employees   should   be   instructed   and  drilled   in   their

                    implementation.    Procedures    should    include   assignment    of

                    individual or team responsibilities and pre-arranged plans for:

                                                   51
<pb n="69" />

                               Immediate evacuation of workers with signs or symptoms

                               of adverse effects resulting from exposure.

                          2.   Transportation    of    injured    persons    to    medical

                               facilities.

                          3.   Any necessary calls to alert medical facilities of the

                               impending arrival of injured persons.

                          4.   Designation of medical receiving facilities and names

                               of physicians trained in anhydrous ammonia emergency

                               procedures.

                7.11 Personnel Safety Training

                    7.11 (a) Informing Employees of Hazards of Chlorine

                          At the beginning of employment, workers whose jobs may

                    involve exposure to chlorine must be informed of the hazards,

                    signs,    symptoms   and   effects    of   overexposure,     emergency

                    procedures,   and precautions to take to ensure safe use of

                    chlorine and to minimize exposure to chlorine. Information

                    pertaining to first-aid procedures should be included.              The

                    information must be posted in the workplace and kept on file,

                    readily accessible to workers at all places of employment where

                    chlorine is involved.

                                                     52
<pb n="70" />

                        A continuing educational program, conducted by a person or

                   persons qualified by reason of experience or special training,

                   must be instituted to ensure that all        workers have current

                   knowledge of job hazards, first-aid procedures, maintenance

                   procedures and cleanup methods, and that they know how to use

                   respiratory    protective   equipment   and   protective    clothing.

                   Retraining should be repeated at least annually.

                   7.11 (b) Training and Drills

                        The value of drills and training in handlin      g emergencies

                   and in using equipment for personal protection and control of

                   escaping chlorine is emphasized in professional literature about

                   the management of chlorine accidents.       National Institute for

                   Occupational Safety and Health (NIOSH) reported a chlorine spill

                   caused by a rail car which discharged chlorine following a

                   collision.    A total of 55 tons of chlorine could have been

                   released into the atmosphere; however, only a few tons escaped

                   because of quick action by employees and supervisory personnel.

                   The quick action was credited to rigorous and thorough training
                   and drills.L28]

                         Members of emergency teams and employees who will work

                   adjacent to chlorine systems or containers should be subjected

                   to periodic drills simulating emergency situations appropriate

                                                   53
<pb n="71" />

                     to the work situation.     These should be held at intervals not

                     exceeding 6 months.      Drills should cover, but should not be

                     limited to, the following:

                               1.    Evacuation procedures;

                               2.    Handling    of    spills    and    leaks,      including

                                     decontamination and use of emergency repair kits;

                               3.    Location    and   use   of   emergency     firefighting

                                     equipment;

                               4.    Handling of containers in case of fire;

                               5.    First aid and rescue,       including procedures for

                                     obtaining medical care;

                               6.    Location, use, and care of protective clothing

                                     and respiratory equipment;

                               7.    Location and use of shut-off valves;

                               8.    Location, reason for, and use of safety showers,

                                     eyewash fountains, and other sources of water for

                                     emergency use;

                               9.    Operating procedures;

                               10.   Entry procedures for confined spaces; and

                               11.   Emergency phone numbers.

                          Deficiencies noted during the drill should form the basis

                     for a continuing educational program to ensure that all workers

                     have   current    knowledge.    Records    of drills     and    training

                     conducted should be established.

                                                      54
<pb n="72" />

                                                        TABLE 7-1

                              EVACUATION TABLE - BASED ON PREVAILING WIND OF 6-12 MPS

                Approximate     Distance to Evacuate             For Maximum Safety
                Size of Spill     From Immediate           Downwind Evacuation
                              Danger Area        Area Should Be

                200 square feet       160 yards (192 paces)       I mile long, 112 mile wide

                400 square feet       240 yards  (288  paces)     1-112 miles long, 1 mile wide

                600 square feet       300 yards  (360  paces)     1-112 miles long, 1 mile wide

                800 square feet       340 yards  (408  paces)     2,112, feet long, 1,584 feet wide

                In the event of   an  explosion, the   minimum safe distance from flying fragments
                is 2,000 feet in all directions.

                Source: Emergency Action Guide for Selected Hazardous Materials, 1978

                                                        54A
<pb n="73" />

                                                 CHAPTER VIII

                                         TRANSPORTAlION OF CHLORINE

                     Chlorine    is  shipped   as   a   liquid  under   pressure    in   steel

                 containers   conforming    to   federal   Department    of    Transportation

                 specifications.    The transportation system needed to move chlorine

                 from the supplier to the OTEC storage tanks requires no new

                 technology.

                     Chlorine can be shipped in bulk, break-bulk or a combination of

                 both.   How the product is finally shipped will be dependent upon a

                 detailed cost comparison of various modes of shipment which are

                 feasible for this product and determination of the additional

                 quantity of chemical needed by the plant during periodic shut down

                 for maintenance.     These quantities will be determined during the

                 preliminary design and engineering stages of the OTEC plant.

                 8.1 Break-bulk Shipment

                     Break-bulk shipment of chlorine is shipment in tanks mounted on

                 the  chassis of open hopper or closed containers.         Tanks transported

                 in this fashion are handled the same as other containerized cargo

                 and require no equipment not presently available at the Port.              The

                 Commercial Port     is primarily a containerized operation, 85% of

                 general cargo being containerized.

                                                       55
<pb n="74" />

                   In a typical unloading scenario, the containers are removed from

               the ship by gantry crane, placed on a chassis and taken directly to

               the plant site.     In event that the containers cannot be taken

               directly to the plant site because of either insufficient chassis or

               lack of storage space at the OTEC plant, Commercial Port container

               yard space will have to be reserved.      The current Master Plan for

               the Commercial Port recommends expansion of the existing container

               yard facilities.    A temporary storage area must be designated and

               reserved prior to delivery of a container shipment in event that

               immediate transfer to the OTEC plant site is delayed.            It   is

               anticipated that adequate storage space will be available at the

               OTEC plant for shipping containers.

               8.2 Ton Containers

                   Limited quantities of chlorine needed to service the plant

               during shut down periods could be imported utilizing one-ton

               containers.    Ton containers for 'liquid chlorine are of steel

               construction. They are fitted with valves of a type approved by the

               Chlorine Institute and which comply with the specifications and

               regulations of the Interstate Commerce Commission.

                   The average ton container is about 30 inches outside diameter

               and about 82 inches in length.     Average tare weight is about 1,500

               pounds and average gross weight is about 3,500 pounds, leaving 2,000

               pounds net weight.

                                                  56
<pb n="75" />

                   Each end of a ton container is concave, the sides being crimped

               inward over the ends to form chimes that provide suitable grips for

               hooks which are used in handling the ton containers.               A ton

               container is equipped with two valves, both of which are located in

               the same end, near the Q,enter.    The valves are connected to eduction

               pipes.   With the container placed so that the two valves are in

               vertical alignment, the lower valve will deliver liquid chlorine

               from above the liquid level.

                   There are six fusible metal plugs, three at each end, of a ton

               container.    The fusible metal in these plugs melts at about
               1580F.[291    This safety device is designed to protect the ton

               container against excessive pressure, caused by high temperatures,

               through melting and allowing the contents of the container to

               escape.   The fusible metal plugs should not be tampered with under

               any circumstances.

                   The container number, dates of hydrostatic tests and capacity

               are stamped in the metal of an unpainted portion of chime at the

               valve end of each ton container.          The tare weight of each ton

               container is stenciled on the end opposite the valves.

                   Portable tanks should be removed from the Commercial Port as

               soon as possible.      If temporary storage is necessary, the tanks

               should be kept away from sources of heat that could increase the

               pressure causing the relief valve to open. The safety plug protects

               the chlorine cylinder against excessive pressure, caused by high

                                                    57
<pb n="76" />

              temperatures,  through melting and allowing the contents of the

              cylinder to escape.   As with any cylinder, care must be taken to

              prevent mechanical damage to the container or its appurtenances.

                                                58
<pb n="77" />

                                           CHAPTER IX

                              GOVERNMENT AUTHORITY AND REGULATIONS

                                FOR HANDLING AMMONIA AND CHLORINE

                 Federal government regulations governing the transportation,

              handling and storage of ammonia and chlorine are divided among three

              agencies: the U.S. Coast Guard, the Environmental Protection Agency

              and The Occupational Safety and Health Administration.     The U.S.

              Coast Guard has the greatest influence on the Commercial Port

              operations due to its wide range of authority in the shipping,

              handling, storage, safety and environmental areas pertinent to

              waterfront facilities and vessels.    The EPA and OSHA Regulations

              influence Commercial Port operations to a much lesser degree.

              9.1 U.S. Coast Guard

                 The U.S. Coast Guard Marine Safety Office (MSO), located in the

              Commercial Port office complex, is responsible for enforcing federal

              laws and regulations for ports, waterways, port facilities as well

              as for protecting vessels, persons, and property in the vicinity o,f

              the ports from accidental or intentional destruction, damage, loss

              or injury.

                  The District Commander, as principal agent and representative of

              the Commandant of the Coast Guard, is responsible for the command

                                               59
<pb n="78" />

                and support of MSO Guam.     This office, located in Honolulu, also

                performs an appellate review role.

                    The Commandant, located in Washington, D.C., directs the policy

                and administration of the Coast Guard, and its implementation of

                legislation, under the general supervision of the Secretary of

                Transporation.   In these matters he is assisted by a staff of

                management and technical assistants who serve as principal advisors.

                    9.1.1 Statutory Authority

                         The following statutes are sufficient to point out the

                    Coast Guard's very broad, and sometimes overlapping, authority

                    to promote safety and protect the marine environment in the

                    transportation and handling of hazardous substances.

                         9.1.1 (a) Title 33 CFR 6.12      "Supervision and Control of

                         Explosives or Other Dangerous Cargo" gives the Coast Guard

                         authority   to   designate  waterfront   facilities  for    the

                         handling, storage, and vessel loading and discharging of

                         explosives, flammable or combustible liquids in bulk, or

                         other dangerous articles.   Authority to require permits for

                         such handling, storage, loading and unloading is also

                         provided.

                                                   60
<pb n="79" />

                       9.1.1 (b) Title 33 CFR 6.14          "Security of Waterfront

                       Facilities and Vessels in Port" authorizes the Coast Guard

                       to prescribe conditions and restrictions relating to the

                       safety of waterfront facilities and vessels        in port as

                       deemed to be necessary under existing circumstances.

                       9.1.1 (c)-313 U.S.C. 1221 et seq     "The Ports and Waterways

                       Safety Act of 1972".      This Act promotes the safety and

                       environmental quality of ports, harbors, waterfront areas,

                       and navigable waters of the ,United States.      The Secretary

                       of the department in which the Coast Guard is operating has

                       been given broad authority to take necessary action to

                       prevent damage to, or the destruction or loss of, any

                       vessel, bridge, or other structure on or in the navigable

                       waters of the United States, or any land structure on shore

                       area immediately adjacent to those waters; and to protect

                       the    navigable   waters    and   resources    therein     from

                       environmental harm resulting from vessel or structural

                       damage, destruction, or loss.

                       9.1.1 (d) FWPCA 33 U.S.C. 1321.          Section 311 of the

                       "Federal Water Pollution Control Act" established United

                       States policy that there shall be no discharges of oil or

                       hazardous substances in harmful quantities into or upon the

                       navigable   waters   of   the   United  States   or    adjoining

                       shorelines.    The Coast Guard has been designated with

                                                  61
<pb n="80" />

                          responsibility for enforcing federal        laws on Guam with

                          regard to oil    and hazardous     substances  entering marine

                          areas.

                          9.1.1. (e) Executive Order 11735.     This order delegates the

                          following facility inspection-related functions of the

                          FWPCA to the Coast Guard:         "... the establishment of

                          procedures, methods, and equipment and other requirements

                          for equipment to prevent discharges of oil and hazardous

                          substances from vessels and transportation-related onshore

                          and offshore facilities, and to contain such discharges."

                    9-.1.2 Local Coast Guard Requirements

                          Designated   dangerous    cargo   may    be   handled,    loaded,

                    discharged or transported at any-designated waterfront facility

                    only if a permit has been issued by the Coast Guard. The permit

                    will terminate automatically at the conclusion of the operation

                    and also may be terminated or suspended whenever the Coast Guard

                    deems that the security or safety of the port, vessels, or

                    waterfront facilities is jeopardized.          The Coast Guard may

                    require additional constraints in th     e permit other than those

                    found in 33 CFR Part 126.

                                                     62
<pb n="81" />

                         The  following    are  two lists     of   possible    additional

                   requirements for vessels and facilities which may be required by

                   the local Coast Guard Marine Safety office to reduce risks of

                   hazardous materials incidents within the port area:

                   9.1.2 (a) Possible Vessels, Requirements

                         Require the vessel to anchor and be inspected prior to

                         permitting transit or commencing transfer.

                         Provide an escort vessel.

                         Require  tugs  to be    in  attendance while the vessel        is

                         transiting the port area or port complex.

                         Establish a moving safety/security zone around the vessel

                         during transit.

                         Restrict vessel    entry and movement to periods of good

                         visibility.

                         Require communications to be constantly maintained between

                         the  vessel   and  the   escort   vessel(s)   including    towing

                         vessel(s).

                         Specify exact transit times permitted.

                                                    63
<pb n="82" />

                         Require a report prior to entry, that all hazardous

                         material cargo alarms, safety devices, and shut-down

                         devices have been tested by the ship personnel and are in

                         good working order.

                    9-.1.2 (b) Possible Facility Requirements

                         Require a pre-transfer conference between ship and terminal

                         personnel.

                         Require effective communications during cargo transfer.

                         Require test of terminal alarm devices and emergency

                         shutdown prior to commencing transfer operations.

                         Prohibit other cargo operations during transfer operations.

                         Prohibit welding, burning, hot-work, smoking, open lights,

                         etc., while the vessel is moored at the terminal.

                         Prohibit bunkering during cargo transfer operations.

                         Require facility operator to post guards and restrict

                         access   to  those   personnel   who  are   essential   to   the

                         operation.

                                                   64
<pb n="83" />

                          Establish a safety/security zone in the area where the

                          vessel is moored.

                          Require facility owners to furnish equipment and resources

                          to patrol the safety/security zones.

                          Require   the   facility   to   provide   or   make    available,

                          additional firefighting equipment and personnel to operate

                          it.

                    9.1.3 Facility of Particular Hazard

                          A "facility of particular hazard" is defined in 33 CFR

                    126.05 (b). The Commercial Port would be designated a "facility

                    of particular hazard" by the U.S. Coast Guard upon authorization

                    to handle a cargo of particular hazard in bulk such as anhydrous

                    ammonia or chlorine. The basic requirements or conditions which

                    must be met are the same as for a "designated waterfront

                    facility",   which   the   Commercial   Port now    meets,   plus    the

                    requirement to have a warning alarm and light.

                    9.2 U.S. Environmental Protection Agency

                          The U.S. Environmental Protection Agency (USEPA) office for

                    the Pacific Islands is located in San Francisco.          There are no

                    USEPA offices on Guam.     The Guam Environmental Protection Agency

                                                     65
<pb n="84" />

                     (GEPA) has been designated by the USEPA to enforce selected

                     USEPA regulations on island.         In addition,    GEPA administers

                     local laws and regulations.

                          The federal responsibility for pollution prevention is

                     divided between the U.S. Coast Guard, and the U.S. Environmental

                     Protection    Agency.    The   USEPA   responsibility    includes    all

                     facilities, both onshore and within the territorial sea limits

                     (within   three   miles),   that   are   not   transportation-related.

                     Included   in   this   definition   of    "non-transportation-related"

                     facilities are those facilities that drill, produce, gather,

                     store, process, refine, transfer, distribute or consume oil and

                     hazardous substances.      USEPA regulations on determination of

                     reportable quantities for hazardous substances (40 CFR 117) sets

                     forth   reportable    quantities   for   hazardous   substances     when

                     discharged into or upon the navigable waters of the United

                     States or adjoining shorelines.      The minimum reportable quantity

                     for an ammonia spill is 100 lbs. (approximately 20 gals.)            The

                     minimum reportable quantity for a chlorine spill is 10 lbs.
                     (approximately one gallon).   1301

                          Facility owners and/or operators are subject to a fine of

                     not more than $10,000 for failure to notify the United States

                     Government of the prohibited discharge.

                                                      66
<pb n="85" />

                         The owner, operator, or person in charge of a vessel or

                    onshore facility from which is discharged a minimum reportable

                    quantity of a hazardous substance is subject to a civil penalty

                    of not more than $5,000.

                         The owner, operator or p    erson in charge will be liable to

                    the United States Government for the actual cost incurred in the

                    removal of a hazardous substance discharged into local waters.

                    It is very unlikely that removal or cleanup operations would be

                    initiated with respect to ammonia or chlorine due to their

                    solubility in sea water.

                         The USEPA has no legal authority over the transportation

                    storage, and handling of ammonia or chlorine.

                    9.3 Occupational Safety and Health Administration

                         The Williams-Steiger Occupational Safety and Health Act of

                    1970   sets   forth  a wide     range  of   standards   which    require

                    conditions, or the adoption or use of one or more practices,

                    means, methods, operations or processes, to provide safe and

                    healthful working conditions.      The U.S. Department of Labor has

                    primary responsibility for administering the act.

                          OSHA regulations are applicable to the Commercial Port and

                    are enforced on island by the Guam Department of Labor in the

                    absence of a federal       OSHA office.      The Commercial    Port    is

                                                     67
<pb n="86" />

                     subject to numerous regulations in 29 CFR Part 1910. This study

                     will only consider additional constraints which can be imposed

                     upon the Commercial Port for storage and handling of anhydrous

                     ammonia or chlorine (29 CFR Part 1910.111).

                           OSHA reguldtions regarding permanent storage areas are not

                     of concern to the Commercial Port.          Since permanent anhydrous

                     ammonia storage containers will be located on the OTEC plant

                     site, portable containers, used to transport ammonia, would be

                     stored at the Port on a temporary basis only.

                           If anhydrous ammonia is obtained from a U.S. supplier and

                     shipped on U.S. Flag vessels, containers will meet or exceed

                     OSHA   requ irements.    U.S.   Coast   Guard     regulations    regarding

                     standards    for   portable    containers    are    stringent  and    U.S.

                     manufacturers     of   ammonia     utilize    containers     which    meet

                     nationally recognized standards for such equipment set forth in

                     OSHA and Coast Guard regulations.

                           There   are    no   additional     OSHA    constraints     addressed

                     specifically to the handling or transportation of chlorine.

                           OSHA    regulations     pertaining    to    full    trailers      and

                     semitrailers that serve the Port are discussed in section 5.2.2

                     of this study.

                                                       68
<pb n="87" />

                                                CHAPTER X

                                            SUMMARY OF TASKS

               10.1 Determine Mode and Frequency of Hazardous Chemical Shipments

                   The ammonia system for a 50 MWe OTEC plant will require an

               initial shipment of approximately 420,000 gallons of ammonia.           The

               initial shipment can be shipped in container or in bulk quantiti'es.

               If make- up quantities needed thereafter are minimal, containerized

               shipments will be feasible.

                   The quantity, mode and frequency of shipment for NH3 is

               directly dependent upon the continuous and intermittent losses of

               ammonia in plant processes.      Continuous losses are possible at the

               glands of pumps and valves,        the turbine seal     system,   and the

               evaporator and condenser tube or tubesheet.          Activities creating

               potential intermittent ammonia losses are manual opening of vent,

               drain,   or   instrument    valves,   relief   activation,   startup    and
               shutdown, equipment venting and ammonia loading operations.[311

                   Quantities of ammonia needed on a recurring basis will be

               determined during preliminary design.       Hence, mode and frequency of

               ammonia shipment cannot be finally determined until             operational

               system losses are quantified.          Ammonia losses and the costs

               associated with the capital and operating costs of the ammonia

                                                    69
<pb n="88" />

                recovery equipment are factors in the economic viability of the

                pl ant.  Leakproof design and ammonia recovery are noted as an early
                design requirement for all equipment.[321

                    Plant chlorine needs can be generated on board, in the form of

                hypochlorite, by passing a direct current through seawater.             The

                plant is assumed to be able to produce its total daily chlorine

                needs while in operation.       Supplemental quantities, needed during

                plant start up and during shutdown periods, will be determined

                during the preliminary design and engineering stages of the OTEC

                plant.

                    Government, safety, hazard and training requirements are, for

                the most part, equally applicable to bulk or container shipment of

                chlorine.

                10.2 Determine Storage Area Needs

                    The Commercial Port Master Plan recommends the expansion of the

                container yard.    If this expansion is undertaken, adequate storage

                capacity for hazardous chemicals will be available at the port if
                needed .[33]

                    Limited   space   on  board   an  OTEC   platform   and   considerable

                shipping distances involved in resupply will necessitate Commercial

                Port storage of chemical for a sea based alternative.

                                                    70
<pb n="89" />

                 Safety and hazard constraints previously delineated should be

              examined when considering storage areas for ammonia and chlorine.

              The U.S. Coast Guard Marine Safety Office recommendations should be

              sought if Commercial Port storage capacity is required for OTEC.

              10.3 Coordinate with U.S. Coast Guard

                 The Coast Guard has indirect facility control by way of

              operational safety regulations and enforcement. The Commercial Port

              management should consult with the Coast Guard, at the earliest

              possible time, after determination of the quantity, frequency and

              mode of hazardous chemical shipment has been defined.

              10.4 Determine Medical Facilities and Support Available

                  Liaison with local medical facilities should be established to

              ensure prompt access to medical support in the event of a chemical

              spill.  Medical facilities should be aware of the types of chemical

              products handled by the Commercial Port that they may be better

              prepared in event of an accident.

                  The following must be established:

                     * Procedures for timely evacuation

                     * Medical facilities capable of treating exposure victims

                     * Procedures for alerting medical facilities of impending

                       arrival of injured persons

                                               71
<pb n="90" />

                         Names  of   physicians   trained   in  ammon i a and   chlorine

                         emergency procedures

                10.5 Coordinate with Fire Department

                   Fire departments likely to respond to a Commercial Port fire

                must be aware of the hazardous chemicals which are handled in

                significant quantities at the port. Local fire stations which would

                respond to a port fire alarm must be equipped with: self-contained

                breathing   apparatus   and    protective   clothing    impervious     to

                chemicals.   Only personnel   properly equipped and trained should

                enter the contaminated area.     Ability of local fire stations to

                respond to a fire involving hazardous chemicals must be determined.

                10.6 Establish Employee Education and Training

                   Shipment of ammonia and/or chlorine in bulk quantities will

                require personnel specifically qualified in the bulk transfer of the

                chemical(s)  involved.   OTEC plant technicians may be capable of

                supervising cargo transfer operations, thereby           releasing the

                Commercial Port from the need to have their personnel trained.        The

                Coast Guard Marine Safety Office will require that satisfactory

                documentary evidence be furnished as proof that the person in charge

                is capable of competently performing all potential operations that

                could evolve in a cargo transfer of a hazardous chemical.

                                                   72
<pb n="91" />

                    Safety in    handl ing  hazardous   chemicals    depends,   to a great

                extent, upon the effectiveness of employee education, proper safety

                instructions, intelligent supervision and use of suitable equipment.

                    Training    of    employees     will     primarily     concern     safety

                considerations involveO with possible exposure to ammonia and

                chlorine.   If the chemicals are shipped in break-bulk quantities,

                the mode of handling will be the same as for any other container

                operation.

                    The education and training of employees in safe work practices

                and the use personal       protective equipment and other safeguards

                provided for them are the responsibility of management.              Training

                classes for both new and old employees should be conducted

                periodically to maintain a high degree of competence.               Employees

                must be thoroughly informed of the hazards that may result from

                improper handling procedures. Each employee must know what to do in

                an emergency and should be fully informed as to appropriate first

                aid measures.

                    The Fertilizer Institute (NH3) and the Chlorine Institute are

                resources for audio-visual training aids which can be used in an

                employee education and training program.

                                                      73
<pb n="92" />

                10.7 Establish a Written Contingency Plan for Emergencies

                    A   compre hens ive contingency    plan   should  be   formulated    to

                minimize    the   potential   effects    of   accidents   at     waterfront

                facilities.   A contingency plan must include procedures for general

                emergencies, fire control and fire fighting systems, emergency

                lighting and power systems, first aid, dock emergencies, response to

                release of hazardous substances and response to other potential

                emergency situations.    The generation of such a plan is a separate

                project which should incorporate all of the parameters embracing the

                transfer of large quantities of ammonia and chlorine as noted in the

                report in addition to routine Commercial Port operations.

                    Timely notification of any discharge of hazardous substances

                into coastal waters is required by federal law.              A discharge

                includes (but is not limited to) any spilling, leaking, pumping,

                pouring, emitting, emptying or dumping of a hazardous substance.

                Procedures should be established in a contingency plan for timely

                notification of the Coast Guard Marine Safety Office and designated

                Commercial Port personnel.     The Coast Guard is presently considering

                a requirement for all facilities to have an emergency manual which

                would basically cover procedures suggested for inclusion in a

                Commercial Port contingency plan for emergencies.

                                                     74
<pb n="93" />

                                                         FOOTNOTES

                     1.           U.S. Department of Energy, Ocean Thermal Energy Conversion Power
                            System Development, National Technical Information Service, December
                            4, 1978.

                     2.           Dames and Moore,     Environmental    Impact Report Projected OTEC
                            Development for Territory of Guam, p. 4, August 15, 1979.

                     3.           Ibid.

                     4.           Maruyama Associates, Ltd. and Dravo Van Houten, Inc., Commercial
                            Port  of Guam Master Plan, draft report September 1980.

                     5            U.S. Department of Energy, Ocean Thermal Energy Conversion Power
                            System Development, National Technical Information Service, SAN
                            1569-2, p. 7-65, December 4, 1980.

                     6.           National Institute for Occupational Safety and Health, Criteria
                            for a Recommended Standard .... Occupational Exposure to Ammonia, NEW
                            publication No. 74-36, p. 5 197T-.-

                     7.           Ibid.$ p. 24.

                     8.           The  Fertilizer      Institute,   Operational    Safety    Manual    for
                            Anhydrous Ammonia, p. 14$ 1971.

                     9.           Ibid. p. 24.

                     10.          The  Fertilizer    Institute,   Chemical    Safety   Data   Sheet    TFI
                            Publication SD-8 p. 15.

                     11.          Ibid.

                     12.          Compressed   Gas   Association,     Inc.,   Anhydrous    Ammonia,     CGA
                            pamphlet G-2, p. 23, 1977.

                     13.          American National Standards Institute, Inc., Safety Requirements
                            for the Storage and Handling of Anhydrous Ammonia, ANSI K61.1, p. 23,
                            T9-72-.

                     14.          U.S. Department of Energy,    Ocean Thermal Energy Conversion Power
                            System Development, National        Technical Information Service, SAN
                            1569-2, p. 6-80 - 6-82, December 4, 1978.

                     15.          U.S. Department of Energy,    Ocean Thermal Energy Conversion Power
                            System Development, National        Technical Information Service, SAN
                            1569-1, Vol. 3, PT. 1 p. 159,, December 4, 1978.

                     16.          Ibid. p. 7-39.

                     17.          Cafky, J.W., Calculations performed September 1980.
<pb n="94" />

                   18.           U.S. Department of Energy, Ocean Thermal Energy Conversion Power
                           System Development, National Technical Information Service, SAN
                           1569-1 Vol. 3, 771, p. 160, December 4, 1978.

                   19.           The Chlorine Institute, Inc. Chlorine N.Y., N.Y. p. 20-21, 1969.

                   20.           National Institute for Occupational Safety and Health, Criteria
                           for a Recommended Standard .... Occupational Exposure to ChlorT-neNEW
                           publication /6-170, p. 3, 1`97F.

                   21.           Dia,nond Shamrock, Inc., op. cit. p. 16.

                   22.           NIOSH, op. cit. p. 109.
                   23.     10017 The Chlorine Institute, Inc., 342 Madison Ave., New York, N.Y.

                   24.           NIOSH, op. cit. p. 106-107.

                   25.           NIOSH, op. cit. p. Ill.

                   26.           Diamond Shamrock, Inc. op. cit.   p. 24.

                   27.           The Chlorine Institute, Inc.      First Aid Medical Management of
                           Chlorine Exporures, Edition 3, June    1978.

                   28.           NIOSH, op. cit. p. 106.

                   29.           Diamond Shamrock, Inc.,.Chlorine Handbook p. 14, 1976.

                   30.           Title 40, Code of Federal Regulations, part 117, Environmental
                           Protection    Agency   Regulations    on    Determination    of    reportable
                           Quantities for Hazardous Substances, Wash. D.C., Government Printing
                           TT-ice.

                   31.           U.S. Department of Energy, Ocean Thermal Energy Conversion Power
                           System Development, National Technical Information service, 50
                           1570-2/1 p. 2.8-6 December 4, 1978.

                   32.           Ibid.

                   33.           Don Hill phone conversation with author 11/13/80.
<pb n="95" />

                                                 BIBLIOGRAPHY

              American National Standard. Practice for Occupational and Educational Eye and
                   Face Protection. ANSI 28T-.F,-7T7-9-.

              American National Standard. Safety Requirements for the Storage and Handling
                   of Anhydrous Ammonia. ANSI pamphlet K61.1,-1972.

              The  Chlorine Institute. Chlorine Institute Emer@ency Kit 'A' For 100-lb. &amp;
                   150 lb. Chlorine Cyli er. Edition 4, July 19/8.

              The  Chlorine Institute. Chlorine Institute Emergency Kit 'B' For Chlorine Ton
                   Containers. Edition 5, July 1978.

              The  Chlorine Institute.  Chlorine Manual. Edition 4, 1969.

              The  Chlorine Institute.  Chlorine Pipelines. Report: 60, Edition 1, June,
                   1971

              The  Chlorine Institute.  Chlorine-Related Audiovisual Training Aids. Pamphlet
                   58, May 1975.

              The  Chlorine Institute.  Facilities and Operating Procedures for Chlorine
                   Storage. Pamphlet 5, Edition 3, Revision 3, October, 1977.

              The  Chlorine Institute.  Estimating Area Affected by a Chlorine Release.
                   Report 71, March, 197T.-

              The  Chlorine Institute. Explosive Properties of Gaseous Mixtures Containing
                   Hydrogen and Chlorine. Edition 1, Report 121, August 1977.

              The  Chlorine Institute. Facilities and Operating Procedures for Chlorine
                   Storage. Pamphlet 5, Edition 3, Revision 3, October, 1977.

              The  Chlorine Institute.  First Aid and Medical Management of Chlorine
                   Exposures. Pamphlet 63.

              The  Chlorine Institute.  Handling of Chlorine Barges. Pamphlet 43, Edition 5,
                   November 1975

              The  Chlorine Institute.  Handling Chlorine Tank Motor Vehicles. Pamphlet 49,
                   Edition 4, 1973.

              The  Chlorine Institute.  Locations of Chlorine Emergency Kits. Pamphlet 35,
                   Edition 13, 1979.

              The  Chlorine Institute.  Protective Chlothing For Chlorine. Pamphlet 65,
                   Edition 1, June 1978.

              Compressed Gas Association, Inc. Anhydrous Ammonia. CGA Pamphlet G-2, Fifth
                   Edition, 1962.
<pb n="96" />

               Department of Commerce National Oceanic and Atmospheric Administration.
                   Coastal Energy Impact Program.  Federal Register Vol. 44, No. 99, May 21,
                   1979.

               Diamond Shamrock. Chlorine Handbook. 1976

               The Fertilizer Institute. Agricultural Anhydrous Ammonia Operator's Manual.
                   Pamphlet M-7, 1978.

               The Fertilizer Institute. Operational Safety Manual for Anhydrous Ammonia.
                   Revised April, 1966

               The Fertilizer Institute. OSHA Handbook. A compilation of relevant OSHA
                   safety and health requirements.

               The Fertilizer Institute. Properties and Recommended Methods for Packaging,
                   Handling, Transportation, Storage and Use of Fertilizer Grade Ammonium
                   17itrate. -

               The Fertilizer Institute. Standards for the Storage and Handling of
                   Agricultural Anhydrous Ammonia. ANI Standard No. M-1, November, 1968

               GODDU Jr., L.W., Guide For Facility Site Evaluation For Proposed Marine
                   Terminals Handling Cargoes of Particular Hazard.    Report No. CG-D-45-79,
                   NTIS, August, 1979.

               Hagopian, J., A.S. Kalelkar and P. K. Raj. Prediction of Hazards of Spills of
                   Anhydrous Ammonia on Water.      National Technical   Information Service,
                     port No. CG-D-74-74, March, 1974.

               Helmers, Scott, Franklin H. Top and L. W. Knapp. Ammonia  and Eye Injuries in
                   Agriculture. The Sigat Saving Review, Vol. 41, No. 1, 1971.

               National Institute For Occupational Safety and Health. A  Guide for Developing
                   a Training Program for Anhydrous Ammonia Workers. Publication No. 79-119,
                   ITecember, 1978.

               Kelly, Christopher. Dealing with Chlorine Emergencies. Fire House. Vol. 2,
                   No. 12, December, 1977.

               National Highway Traffic Safety Administration and Materials Transportation
                   Bureau.  Emergency Action Guide for Selected Hazardous Materials, Wash.
                   D.C., U.S. Government Printing Office, 1973.

               National Institute for Occupational Safety and Health. Occupational Exposure
                   to Ammonia. U.S. Government Printing Office, Washington, D.C., 1974.

               National Institute for Occupational Safety and Health. Occupational Exposure
                   to Chlorine. U.S. Government Printing Office, Washington, D.C., 1976.

               National Institute For Occupational Safety and Health. Respiratory Protection
                   A Guide for the Employee. Report No. 78-193B, October 1978.
<pb n="97" />

              National Institute for Occupational Satety and Helath. Respiratory
                  Protection:  An Employer's Manual.   Publication No. 78-T9-37, October 1978.

              National Institute for Occupational Safety and Health. Working Safely With
                  Anhydrous Ammonia.  Publications No. 79-120, January, 1979.

              National Safety Council. Chlorine. Data Sheet 207, 1966.

              U.S. Coast Guard. Marine Safety Manual (CG-495). Washington D.C. U.S.
                  Government Printing Office, 1977.                          1

              U.S. Department of Energy. Ocean Thermal Energy Conversion Power System
                  Development (SAN 1569-1, Vol. 2, Pt. 1)

              U.S. Department of Energy. Ocean Thermal Energy Conversion Power System
                  Development  (SAN 1569-1, Vol. 2, Pt. 2), NTIS

              U.S. Department of Energy. Ocean Thermal Energy Conversion Power System
                  Development. (SAN-1569-2) NTIS, 1978

              U.S. Department of Energy. Ocean Thermal Energy Conversion Power System
                  Development  (SAN 1570-2/1) NTIS

              U.S. Department of Energy. Ocean Thermal Energy Conversion Power System
                  Development. (SAN 1570 2/3). NTIS

              U.S. Department of Labor. Chlorine Handling in Operations. Bulletin No. 241,
                  1962.

              U.S. Department of Labor. Occupational Safety and Health Admi   nistration.
                  General Industry Safety and Health Standards (29 CFR 1910). January 1976.
<pb n="98" />

                                                                  I 1111811IMMIN
                                                                     3 6668 14109 7545
</text>