<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
    <FDSYS>
        <CFRTITLE>40</CFRTITLE>
        <CFRTITLETEXT>Protection of Environment</CFRTITLETEXT>
        <VOL>21</VOL>
        <DATE>2024-07-01</DATE>
        <ORIGINALDATE>2024-07-01</ORIGINALDATE>
        <COVERONLY>false</COVERONLY>
        <TITLE>Prohibitions and required practices.</TITLE>
        <GRANULENUM>82.34</GRANULENUM>
        <HEADING>Section 82.34</HEADING>
        <ANCESTORS>
            <PARENT HEADING="Title 40" SEQ="4">Protection of Environment</PARENT>
            <PARENT HEADING="CHAPTER I" SEQ="3">ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)</PARENT>
            <PARENT HEADING="SUBCHAPTER C" SEQ="2">AIR PROGRAMS (CONTINUED)</PARENT>
            <PARENT HEADING="PART 82" SEQ="1">PROTECTION OF STRATOSPHERIC OZONE</PARENT>
            <PARENT HEADING="Subpart B" SEQ="0">Servicing of Motor Vehicle Air Conditioners</PARENT>
        </ANCESTORS>
    </FDSYS>
    <SECTION>
        <SECTNO>§ 82.34</SECTNO>
        <SUBJECT>Prohibitions and required practices.</SUBJECT>
        <P>(a) No person repairing or servicing MVACs for consideration, and no person repairing or servicing MVAC-like appliances, may perform any service involving the refrigerant for such MVAC or MVAC-like appliance:</P>
        <P>(1) Without properly using equipment approved pursuant to § 82.36;</P>
        <P>(2) Unless any such person repairing or servicing an MVAC has been properly trained and certified by a technician certification program approved by the Administrator pursuant to § 82.40; and</P>
        <P>(3) Unless any such person repairing or servicing an MVAC-like appliance has been properly trained and certified by a technician certification program approved by the Administrator pursuant to either § 82.40 or § 82.161(a)(5).</P>
        <P>(b) Effective November 15, 1992, no person may sell or distribute, or offer for sale or distribution, any class I or class II substance that is suitable for use as a refrigerant in motor vehicle air-conditioner and that is in a container which contains less than 20 pounds of such refrigerant to any person unless that person is properly trained and certified under § 82.40 or intended the containers for resale only, and so certifies to the seller under § 82.42(b)(3).</P>
        <P>(c) No technician training programs may issue certificates unless the program complies with all of the standards in § 82.40(a).</P>
        <P>
            (d) 
            <E T="03">Motor vehicle disposal facilities.</E>
             (1) Any refrigerant that is extracted from an MVAC or an MVAC-like appliance (as that term is defined in § 82.152) bound for disposal and located at a motor vehicle disposal facility may not be subsequently used to charge or recharge an MVAC or MVAC-like appliance, unless, prior to such charging or recharging, the refrigerant is either:
        </P>
        <P>(i) Recovered, and reclaimed in accordance with the regulations promulgated under § 82.32(e)(2) of this subpart B; or</P>
        <P>(ii) (A) Recovered using approved refrigerant recycling equipment dedicated for use with MVACs and MVAC-like appliances, either by a technician certified under paragraph (a)(2) of this section, or by an employee, owner, or operator of, or contractor to, the disposal facility; and</P>
        <P>(B) Subsequently recycled by the facility that charges or recharges the refrigerant into an MVAC or MVAC-like appliance, properly using approved refrigerant recycling equipment in accordance with any applicable recommended service procedures set forth in the appendices to this subpart B.</P>
        <P>
            (2) Any refrigerant the sale of which is restricted under subpart F that is extracted from an MVAC or an MVAC-like appliance bound for disposal and located at a motor vehicle disposal facility but not subsequently reclaimed in accordance with the regulations promulgated under subpart F, may be sold prior to its subsequent re-use only to a technician certified under paragraph 
            <PRTPAGE P="80"/>
            (a)(2) of this section. Any technician certified under paragraph (a)(2) of this section who obtains such a refrigerant may subsequently re-use such refrigerant only in an MVAC or MVAC-like appliance, and only if it has been reclaimed or properly recycled.
        </P>
        <P>(e) Refrigerant handling equipment manufactured or imported for use during the maintenance, service or repair of MVACs for consideration cannot be introduced into interstate commerce unless meeting the requirements of § 82.36.</P>
        <CITA>[57 FR 31261, July 14, 1992, as amended at 62 FR 68047, Dec. 30, 1997; 72 FR 63494, Nov. 9, 2007]</CITA>
    </SECTION>