        <SECTNO>§ 159.7</SECTNO>
        <SUBJECT>Requirements for vessel operators.</SUBJECT>
        <P>(a) No person may operate any vessel equipped with installed toilet facilities unless it is equipped with:</P>
        <P>(1) An operable Type II or III device that has a label on it under § 159.16 or that is certified under § 159.12 or § 159.12a; or</P>
        <P>
            (2) An operable Type I device that has a label on it under § 159.16 or that is certified under § 159.12, if the vessel is 19.7 meters (65 feet) or less in length.
            <PRTPAGE P="587"/>
        </P>
        <P>(b) When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3 or 140.4, the operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage. Acceptable methods of securing the device include—</P>
        <P>(1) Closing the seacock and removing the handle;</P>
        <P>(2) Padlocking the seacock in the closed position;</P>
        <P>(3) Using a non-releasable wire-tie to hold the seacock in the closed position; or</P>
        <P>(4) Locking the door to the space enclosing the toilets with a padlock or door handle key lock.</P>
        <P>(c) When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3, the operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods of securing the device include—</P>
        <P>(1) Closing each valve leading to an overboard discharge and removing the handle;</P>
        <P>(2) Padlocking each valve leading to an overboard discharge in the closed position; or</P>
        <P>(3) Using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position.</P>
        <CITA>[CGH 95-028, 62 FR 51194, Sept. 30, 1997]</CITA>