<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>40</CFRTITLE>
    <CFRTITLETEXT>Protection of Environment</CFRTITLETEXT>
    <VOL>7</VOL>
    <DATE>2015-07-01</DATE>
    <ORIGINALDATE>2015-07-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Definitions.</TITLE>
    <GRANULENUM>Â§ 60.41</GRANULENUM>
    <HEADING>Section Â§ 60.41</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="4">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER C" SEQ="2">AIR PROGRAMS (CONTINUED)</PARENT>
      <PARENT HEADING="PART 60" SEQ="1">STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES</PARENT>
      <PARENT HEADING="Subpart D" SEQ="0">Standards of Performance for Fossil-Fuel-Fired Steam Generators</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 60.41</SECTNO>
    <SUBJECT>Definitions.</SUBJECT>
    <P>As used in this subpart, all terms not defined herein shall have the meaning given them in the Act, and in subpart A of this part.</P>
    <P>
      <E T="03">Boiler operating day</E> means a 24-hour period between 12 midnight and the following midnight during which any fuel is combusted at any time in the steam-generating unit. It is not necessary for fuel to be combusted the entire 24-hour period.</P>
    <P>
      <E T="03">Coal</E> means all solid fuels classified as anthracite, bituminous, subbituminous, or lignite by ASTM D388 (incorporated by reference, see § 60.17).</P>
    <P>
      <E T="03">Coal refuse</E> means waste-products of coal mining, cleaning, and coal preparation operations (e.g. culm, gob, etc.) containing coal, matrix material, clay, <PRTPAGE P="138"/>and other organic and inorganic material.</P>
    <P>
      <E T="03">Fossil fuel</E> means natural gas, petroleum, coal, and any form of solid, liquid, or gaseous fuel derived from such materials for the purpose of creating useful heat.</P>
    <P>
      <E T="03">Fossil fuel and wood residue-fired steam generating unit</E> means a furnace or boiler used in the process of burning fossil fuel and wood residue for the purpose of producing steam by heat transfer.</P>
    <P>
      <E T="03">Fossil-fuel-fired steam generating unit</E> means a furnace or boiler used in the process of burning fossil fuel for the purpose of producing steam by heat transfer.</P>
    <P>
      <E T="03">Natural gas</E> means a fluid mixture of hydrocarbons (e.g., methane, ethane, or propane), composed of at least 70 percent methane by volume or that has a gross calorific value between 35 and 41 megajoules (MJ) per dry standard cubic meter (950 and 1,100 Btu per dry standard cubic foot), that maintains a gaseous state under ISO conditions. In addition, <E T="03">natural gas</E> contains 20.0 grains or less of total sulfur per 100 standard cubic feet. Finally, natural gas does not include the following gaseous fuels: landfill gas, digester gas, refinery gas, sour gas, blast furnace gas, coal-derived gas, producer gas, coke oven gas, or any gaseous fuel produced in a process which might result in highly variable sulfur content or heating value.</P>
    <P>
      <E T="03">Wood residue</E> means bark, sawdust, slabs, chips, shavings, mill trim, and other wood products derived from wood processing and forest management operations.</P>
    <CITA>[72 FR 32717, June 13, 2007, as amended at 77 FR 9447, Feb. 16, 2012]</CITA>