<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>40</CFRTITLE>
    <CFRTITLETEXT>Protection of Environment</CFRTITLETEXT>
    <VOL>15</VOL>
    <DATE>2015-07-01</DATE>
    <ORIGINALDATE>2015-07-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Emission Limits for Existing EGUs</TITLE>
    <GRANULENUM>2</GRANULENUM>
    <HEADING>Table 2 to Subpart UUUUU of Part 63</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="4">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER C" SEQ="2">AIR PROGRAMS (CONTINUED)</PARENT>
      <PARENT HEADING="PART 63" SEQ="1">NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED)</PARENT>
      <PARENT HEADING="Subpart UUUUU" SEQ="0">National Emission Standards for Hazardous Air Pollutants: Coal- and Oil-Fired Electric Utility Steam Generating Units</PARENT>
    </ANCESTORS>
  </FDSYS>
  <APPENDIX>
    <EAR>Pt. 63, Subpt. UUUUU, Table 2</EAR>
    <HD SOURCE="HED">Table 2 to Subpart UUUUU of Part 63—Emission Limits for Existing EGUs</HD>
    <P>As stated in § 63.9991, you must comply with the following applicable emission limits: <SU>1</SU>
    </P>
    <GPOTABLE CDEF="s50,r50,xl50,r50" COLS="4" OPTS="L2">
      <BOXHD>
        <CHED H="1" O="L">If your EGU is in this subcategory . . .</CHED>
        <CHED H="1" O="L">For the following pollutants . . .</CHED>
        <CHED H="1" O="L">You must meet the following emission limits and work practice standards . . .</CHED>
        <CHED H="1" O="L">Using these requirements, as appropriate (e.g., specified sampling volume or test run duration) and limitations with the test methods in Table 5 . . .</CHED>
      </BOXHD>
      <ROW>
        <ENT I="01">1. Coal-fired unit not low rank virgin coal</ENT>
        <ENT>a. Filterable particulate matter (PM)</ENT>
        <ENT>3.0E-2 lb/MMBtu or 3.0E-1 lb/MWh.<SU>2</SU>
        </ENT>
        <ENT>Collect a minimum of 1 dscm per run.</ENT>
      </ROW>
      <ROW>
        <PRTPAGE P="207"/>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Total non-Hg HAP metals</ENT>
        <ENT>5.0E-5 lb/MMBtu or 5.0E-1 lb/GWh.</ENT>
        <ENT>Collect a minimum of 1 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">Individual HAP metals:</ENT>
        <ENT/>
        <ENT>Collect a minimum of 3 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Antimony (Sb)</ENT>
        <ENT>8.0E-1 lb/TBtu or 8.0E-3 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Arsenic (As)</ENT>
        <ENT>1.1E0 lb/TBtu or 2.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Beryllium (Be)</ENT>
        <ENT>2.0E-1 lb/TBtu or 2.0E-3 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cadmium (Cd)</ENT>
        <ENT>3.0E-1 lb/TBtu or 3.0E-3 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Chromium (Cr)</ENT>
        <ENT>2.8E0 lb/TBtu or 3.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cobalt (Co)</ENT>
        <ENT>8.0E-1 lb/TBtu or 8.0E-3 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Lead (Pb)</ENT>
        <ENT>1.2E0 lb/TBtu or 2.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Manganese (Mn)</ENT>
        <ENT>4.0E0 lb/TBtu or 5.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Nickel (Ni)</ENT>
        <ENT>3.5E0 lb/TBtu or 4.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Selenium (Se)</ENT>
        <ENT>5.0E0 lb/TBtu or 6.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>b. Hydrogen chloride (HCl)</ENT>
        <ENT>2.0E-3 lb/MMBtu or 2.0E-2 lb/MWh.</ENT>
        <ENT>For Method 26A, collect a minimum of 0.75 dscm per run; for Method 26, collect a minimum of 120 liters per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT O="xl"/>
        <ENT>For ASTM D6348-03 <SU>3</SU> or Method 320, sample for a minimum of 1 hour.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT/>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Sulfur dioxide (SO<E T="52">2</E>) <SU>4</SU>
        </ENT>
        <ENT>2.0E-1 lb/MMBtu or 1.5E0 lb/MWh.</ENT>
        <ENT>SO<E T="52">2</E> CEMS.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>c. Mercury (Hg)</ENT>
        <ENT O=".">1.2E0 lb/TBtu or 1.3E-2 lb/GWh</ENT>
        <ENT>LEE Testing for 30 days with 10 days maximum per Method 30B run or Hg CEMS or sorbent trap monitoring system only.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">2. Coal-fired unit low rank virgin coal</ENT>
        <ENT>a. Filterable particulate matter (PM)</ENT>
        <ENT>3.0E-2 lb/MMBtu or 3.0E-1 lb/MWh.<SU>2</SU>
        </ENT>
        <ENT>Collect a minimum of 1 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Total non-Hg HAP metals</ENT>
        <ENT>5.0E-5 lb/MMBtu or 5.0E-1 lb/GWh.</ENT>
        <ENT>Collect a minimum of 1 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">Individual HAP metals:</ENT>
        <ENT/>
        <ENT>Collect a minimum of 3 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Antimony (Sb)</ENT>
        <ENT>8.0E-1 lb/TBtu or 8.0E-3 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Arsenic (As)</ENT>
        <ENT>1.1E0 lb/TBtu or 2.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Beryllium (Be)</ENT>
        <ENT>2.0E-1 lb/TBtu or 2.0E-3 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cadmium (Cd)</ENT>
        <ENT>3.0E-1 lb/TBtu or 3.0E-3 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Chromium (Cr)</ENT>
        <ENT>2.8E0 lb/TBtu or 3.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cobalt (Co)</ENT>
        <ENT>8.0E-1 lb/TBtu or 8.0E-3 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Lead (Pb)</ENT>
        <ENT>1.2E0 lb/TBtu or 2.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Manganese (Mn)</ENT>
        <ENT>4.0E0 lb/TBtu or 5.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Nickel (Ni)</ENT>
        <ENT>3.5E0 lb/TBtu or 4.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Selenium (Se)</ENT>
        <ENT>5.0E0 lb/TBtu or 6.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <PRTPAGE P="208"/>
        <ENT I="22"> </ENT>
        <ENT>b. Hydrogen chloride (HCl)</ENT>
        <ENT>2.0E-3 lb/MMBtu or 2.0E-2 lb/MWh.</ENT>
        <ENT>For Method 26A, collect a minimum of 0.75 dscm per run; for Method 26, collect a minimum of 120 liters per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"> </ENT>
        <ENT O="xl"> </ENT>
        <ENT>For ASTM D6348-03 <SU>3</SU> or Method 320, sample for a minimum of 1 hour.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Sulfur dioxide (SO<E T="52">2</E>) <SU>4</SU>
        </ENT>
        <ENT>2.0E-1 lb/MMBtu or 1.5E0 lb/MWh.</ENT>
        <ENT>SO<E T="52">2</E> CEMS.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>c. Mercury (Hg)</ENT>
        <ENT O=".">4.0E0 lb/TBtu or 4.0E-2 lb/GWh</ENT>
        <ENT>LEE Testing for 30 days with 10 days maximum per Method 30B run or Hg CEMS or sorbent trap monitoring system only.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">3. IGCC unit</ENT>
        <ENT>a. Filterable particulate matter (PM)</ENT>
        <ENT>4.0E-2 lb/MMBtu or 4.0E-1 lb/MWh.<SU>2</SU>
        </ENT>
        <ENT>Collect a minimum of 1 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Total non-Hg HAP metals</ENT>
        <ENT>6.0E-5 lb/MMBtu or 5.0E-1 lb/GWh.</ENT>
        <ENT>Collect a minimum of 1 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">Individual HAP metals:</ENT>
        <ENT/>
        <ENT>Collect a minimum of 2 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Antimony (Sb)</ENT>
        <ENT>1.4E0 lb/TBtu or 2.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Arsenic (As)</ENT>
        <ENT>1.5E0 lb/TBtu or 2.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Beryllium (Be)</ENT>
        <ENT>1.0E-1 lb/TBtu or 1.0E-3 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cadmium (Cd)</ENT>
        <ENT>1.5E-1 lb/TBtu or 2.0E-3 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Chromium (Cr)</ENT>
        <ENT>2.9E0 lb/TBtu or 3.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cobalt (Co)</ENT>
        <ENT>1.2E0 lb/TBtu or 2.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Lead (Pb)</ENT>
        <ENT>1.9E+2 lb/TBtu or 1.8E0 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Manganese (Mn)</ENT>
        <ENT>2.5E0 lb/TBtu or 3.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Nickel (Ni)</ENT>
        <ENT>6.5E0 lb/TBtu or 7.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Selenium (Se)</ENT>
        <ENT>2.2E+1 lb/TBtu or 3.0E-1 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>b. Hydrogen chloride (HCl)</ENT>
        <ENT>5.0E-4 lb/MMBtu or 5.0E-3 lb/MWh.</ENT>
        <ENT>For Method 26A, collect a minimum of 1 dscm per run; for Method 26, collect a minimum of 120 liters per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT O="xl"/>
        <ENT>For ASTM D6348-03 <SU>3</SU> or Method 320, sample for a minimum of 1 hour.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>c. Mercury (Hg)</ENT>
        <ENT O=".">2.5E0 lb/TBtu or 3.0E-2 lb/GWh</ENT>
        <ENT>LEE Testing for 30 days with 10 days maximum per Method 30B run or Hg CEMS or sorbent trap monitoring system only.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">4. Liquid oil-fired unit—continental (excluding limited-use liquid oil-fired subcategory units)</ENT>
        <ENT>a. Filterable particulate matter (PM)</ENT>
        <ENT>3.0E-2 lb/MMBtu or 3.0E-1 lb/MWh.<SU>2</SU>
        </ENT>
        <ENT>Collect a minimum of 1 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Total HAP metals</ENT>
        <ENT>8.0E-4 lb/MMBtu or 8.0E-3 lb/MWh.</ENT>
        <ENT>Collect a minimum of 1 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">Individual HAP metals:</ENT>
        <ENT/>
        <ENT>Collect a minimum of 1 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Antimony (Sb)</ENT>
        <ENT>1.3E+1 lb/TBtu or 2.0E-1 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <PRTPAGE P="209"/>
        <ENT I="22"> </ENT>
        <ENT>Arsenic (As)</ENT>
        <ENT>2.8E0 lb/TBtu or 3.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Beryllium (Be)</ENT>
        <ENT>2.0E-1 lb/TBtu or 2.0E-3 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cadmium (Cd)</ENT>
        <ENT>3.0E-1 lb/TBtu or 2.0E-3 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Chromium (Cr)</ENT>
        <ENT>5.5E0 lb/TBtu or 6.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cobalt (Co)</ENT>
        <ENT>2.1E+1 lb/TBtu or 3.0E-1 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Lead (Pb)</ENT>
        <ENT>8.1E0 lb/TBtu or 8.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Manganese (Mn)</ENT>
        <ENT>2.2E+1 lb/TBtu or 3.0E-1 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Nickel (Ni)</ENT>
        <ENT>1.1E+2 lb/TBtu or 1.1E0 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Selenium (Se)</ENT>
        <ENT>3.3E0 lb/TBtu or 4.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Mercury (Hg)</ENT>
        <ENT>2.0E-1 lb/TBtu or 2.0E-3 lb/GWh.</ENT>
        <ENT>For Method 30B sample volume determination (Section 8.2.4), the estimated Hg concentration should nominally be &lt;<FR>1/2</FR>; the standard.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>b. Hydrogen chloride (HCl)</ENT>
        <ENT>2.0E-3 lb/MMBtu or 1.0E-2 lb/MWh.</ENT>
        <ENT>For Method 26A, collect a minimum of 1 dscm per Run; for Method 26, collect a minimum of 120 liters per run.<LI>For ASTM D6348-03 <SU>3</SU> or Method 320, sample for a minimum of 1 hour.</LI>
        </ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>c. Hydrogen fluoride (HF)</ENT>
        <ENT>4.0E-4 lb/MMBtu or 4.0E-3 lb/MWh.</ENT>
        <ENT>For Method 26A, collect a minimum of 1 dscm per run; for Method 26, collect a minimum of 120 liters per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT O="xl"/>
        <ENT>For ASTM D6348-03 <SU>3</SU> or Method 320, sample for a minimum of 1 hour.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">5. Liquid oil-fired unit—non-continental (excluding limited-use liquid oil-fired subcategory units)</ENT>
        <ENT>a. Filterable particulate matter (PM)</ENT>
        <ENT>3.0E-2 lb/MMBtu or 3.0E-1 lb/MWh.<SU>2</SU>
        </ENT>
        <ENT>Collect a minimum of 1 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">Total HAP metals</ENT>
        <ENT>6.0E-4 lb/MMBtu or 7.0E-3 lb/MWh.</ENT>
        <ENT>Collect a minimum of 1 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">Individual HAP metals:</ENT>
        <ENT/>
        <ENT>Collect a minimum of 2 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Antimony (Sb)</ENT>
        <ENT>2.2E0 lb/TBtu or 2.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Arsenic (As)</ENT>
        <ENT>4.3E0 lb/TBtu or 8.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Beryllium (Be)</ENT>
        <ENT>6.0E-1 lb/TBtu or 3.0E-3 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cadmium (Cd)</ENT>
        <ENT>3.0E-1 lb/TBtu or 3.0E-3 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Chromium (Cr)</ENT>
        <ENT>3.1E+1 lb/TBtu or 3.0E-1 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cobalt (Co)</ENT>
        <ENT>1.1E+2 lb/TBtu or 1.4E0 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Lead (Pb)</ENT>
        <ENT>4.9E0 lb/TBtu or 8.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Manganese (Mn)</ENT>
        <ENT>2.0E+1 lb/TBtu or 3.0E-1 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Nickel (Ni)</ENT>
        <ENT>4.7E+2 lb/TBtu or 4.1E0 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Selenium (Se)</ENT>
        <ENT>9.8E0 lb/TBtu or 2.0E-1 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <PRTPAGE P="210"/>
        <ENT I="22"> </ENT>
        <ENT>Mercury (Hg)</ENT>
        <ENT>4.0E-2 lb/TBtu or 4.0E-4 lb/GWh.</ENT>
        <ENT>For Method 30B sample volume determination (Section 8.2.4), the estimated Hg concentration should nominally be &lt;<FR>1/2</FR>; the standard.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>b. Hydrogen chloride (HCl)</ENT>
        <ENT>2.0E-4 lb/MMBtu or 2.0E-3 lb/MWh.</ENT>
        <ENT>For Method 26A, collect a minimum of 1 dscm per run; for Method 26, collect a minimum of 120 liters per run.<LI>For ASTM D6348-03 <SU>3</SU> or Method 320, sample for a minimum of 2 hours.</LI>
        </ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>c. Hydrogen fluoride (HF)</ENT>
        <ENT>6.0E-5 lb/MMBtu or 5.0E-4 lb/MWh.</ENT>
        <ENT>For Method 26A, collect a minimum of 3 dscm per run.<LI>For ASTM D6348-03 <SU>3</SU> or Method 320, sample for a minimum of 2 hours.</LI>
        </ENT>
      </ROW>
      <ROW>
        <ENT I="01">6. Solid oil-derived fuel-fired unit</ENT>
        <ENT>a. Filterable particulate matter (PM)</ENT>
        <ENT>8.0E-3 lb/MMBtu or 9.0E-2 lb/MWh.<SU>2</SU>
        </ENT>
        <ENT>Collect a minimum of 1 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Total non-Hg HAP metals</ENT>
        <ENT>4.0E-5 lb/MMBtu or 6.0E-1 lb/GWh.</ENT>
        <ENT>Collect a minimum of 1 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Individual HAP metals</ENT>
        <ENT>Collect a minimum of 3 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Antimony (Sb)</ENT>
        <ENT>8.0E-1 lb/TBtu or 7.0E-3 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Arsenic (As)</ENT>
        <ENT>3.0E-1 lb/TBtu or 5.0E-3 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Beryllium (Be)</ENT>
        <ENT>6.0E-2 lb/TBtu or 5.0E-4 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cadmium (Cd)</ENT>
        <ENT>3.0E-1 lb/TBtu or 4.0E-3 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Chromium (Cr)</ENT>
        <ENT>8.0E-1 lb/TBtu or 2.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cobalt (Co)</ENT>
        <ENT>1.1E0 lb/TBtu or 2.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Lead (Pb)</ENT>
        <ENT>8.0E-1 lb/TBtu or 2.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Manganese (Mn)</ENT>
        <ENT>2.3E0 lb/TBtu or 4.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Nickel (Ni)</ENT>
        <ENT>9.0E0 lb/TBtu or 2.0E-1 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Selenium (Se)</ENT>
        <ENT>1.2E0 lb/TBtu or 2.0E-2 lb/GWh.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>b. Hydrogen chloride (HCl)</ENT>
        <ENT>5.0E-3 lb/MMBtu or 8.0E-2 lb/MWh.</ENT>
        <ENT>For Method 26A, collect a minimum of 0.75 dscm per run; for Method 26, collect a minimum of 120 liters per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT O="xl"/>
        <ENT>For ASTM D6348-03 <SU>3</SU> or Method 320, sample for a minimum of 1 hour.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl"/>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Sulfur dioxide (SO<E T="52">2</E>) <SU>4</SU>
        </ENT>
        <ENT>3.0E-1 lb/MMBtu or 2.0E0 lb/MWh.</ENT>
        <ENT>SO<E T="52">2</E> CEMS.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>c. Mercury (Hg)</ENT>
        <ENT>2.0E-1 lb/TBtu or 2.0E-3 lb/GWh.</ENT>
        <ENT>LEE Testing for 30 days with 10 days maximum per Method 30B run or Hg CEMS or Sorbent trap monitoring system only.</ENT>
      </ROW>
      <TNOTE>
        <SU>1</SU> For LEE emissions testing for total PM, total HAP metals, individual HAP metals, HCl, and HF, the required minimum sampling volume must be increased nominally by a factor of two.</TNOTE>
      <TNOTE>
        <SU>2</SU> Gross electric output.</TNOTE>
      <TNOTE>
        <SU>3</SU> Incorporated by reference, see § 63.14.</TNOTE>
      <TNOTE>
        <SU>4</SU> You may not use the alternate SO<E T="52">2</E> limit if your EGU does not have some form of FGD system and SO<E T="52">2</E> CEMS installed.</TNOTE>
    </GPOTABLE>
    <PRTPAGE P="211"/>
    <CITA>[77 FR 23405, Apr. 19, 2012]</CITA>
  </APPENDIX>