<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>40</CFRTITLE>
    <CFRTITLETEXT>Protection of Environment</CFRTITLETEXT>
    <VOL>15</VOL>
    <DATE>2015-07-01</DATE>
    <ORIGINALDATE>2015-07-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Emission Limits for New or Reconstructed EGUs</TITLE>
    <GRANULENUM>1</GRANULENUM>
    <HEADING>Table 1 to Subpart UUUUU of Part 63</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="4">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER C" SEQ="2">AIR PROGRAMS (CONTINUED)</PARENT>
      <PARENT HEADING="PART 63" SEQ="1">NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED)</PARENT>
      <PARENT HEADING="Subpart UUUUU" SEQ="0">National Emission Standards for Hazardous Air Pollutants: Coal- and Oil-Fired Electric Utility Steam Generating Units</PARENT>
    </ANCESTORS>
  </FDSYS>
  <APPENDIX>
    <EAR>Pt. 63, Subpt. UUUUU, Table 1</EAR>
    <HD SOURCE="HED">Table 1 to Subpart UUUUU of Part 63—Emission Limits for New or Reconstructed EGUs</HD>

    <P>As stated in § 63.9991, you must comply with the following applicable emission limits:<PRTPAGE P="204"/>
    </P>
    <GPOTABLE CDEF="s50,r50,r50,r50" COLS="4" OPTS="L2">
      <BOXHD>
        <CHED H="1" O="L">If your EGU is in this subcategory</CHED>
        <CHED H="1" O="L">For the following pollutants</CHED>
        <CHED H="1" O="L">You must meet the following emission limits and work practice standards</CHED>
        <CHED H="1" O="L">Using these requirements, as appropriate (e.g., specified sampling volume or test run duration) and limitations with the test methods in Table 5</CHED>
      </BOXHD>
      <ROW>
        <ENT I="01">1. Coal-fired unit not low rank virgin coal</ENT>
        <ENT>a. Filterable particulate matter (PM)</ENT>
        <ENT>9.0E-2 lb/MWh <SU>1</SU>
        </ENT>
        <ENT>Collect a minimum of 4 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Total non-Hg HAP metals</ENT>
        <ENT>6.0E-2 lb/GWh</ENT>
        <ENT>Collect a minimum of 4 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Individual HAP metals:</ENT>
        <ENT/>
        <ENT>Collect a minimum of 3 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Antimony (Sb)</ENT>
        <ENT>8.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Arsenic (As)</ENT>
        <ENT>3.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Beryllium (Be)</ENT>
        <ENT>6.0E-4 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cadmium (Cd)</ENT>
        <ENT>4.0E-4 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Chromium (Cr)</ENT>
        <ENT>7.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cobalt (Co)</ENT>
        <ENT>2.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Lead (Pb)</ENT>
        <ENT>2.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Manganese (Mn)</ENT>
        <ENT>4.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Nickel (Ni)</ENT>
        <ENT>4.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Selenium (Se)</ENT>
        <ENT>5.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>b. Hydrogen chloride (HCl)</ENT>
        <ENT>1.0E-2 lb/MWh</ENT>
        <ENT>For Method 26A, collect a minimum of 3 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT O="xl"/>
        <ENT>For ASTM D6348-03 <SU>2</SU> or Method 320, sample for a minimum of 1 hour.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT/>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Sulfur dioxide (SO<E T="52">2</E>) <SU>3</SU>
        </ENT>
        <ENT>1.0 lb/MWh</ENT>
        <ENT>SO<E T="52">2</E> CEMS.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>c. Mercury (Hg)</ENT>
        <ENT>3.0E-3 lb/GWh</ENT>
        <ENT>Hg CEMS or sorbent trap monitoring system only.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">2. Coal-fired units low rank virgin coal</ENT>
        <ENT>a. Filterable particulate matter (PM)</ENT>
        <ENT>9.0E-2 lb/MWh <SU>1</SU>
        </ENT>
        <ENT>Collect a minimum of 4 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Total non-Hg HAP metals</ENT>
        <ENT>6.0E-2 lb/GWh</ENT>
        <ENT>Collect a minimum of 4 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Individual HAP metals:</ENT>
        <ENT/>
        <ENT>Collect a minimum of 3 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Antimony (Sb)</ENT>
        <ENT>8.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Arsenic (As)</ENT>
        <ENT>3.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Beryllium (Be)</ENT>
        <ENT>6.0E-4 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cadmium (Cd)</ENT>
        <ENT>4.0E-4 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Chromium (Cr)</ENT>
        <ENT>7.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cobalt (Co)</ENT>
        <ENT>2.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Lead (Pb)</ENT>
        <ENT>2.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Manganese (Mn)</ENT>
        <ENT>4.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Nickel (Ni)</ENT>
        <ENT>4.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Selenium (Se)</ENT>
        <ENT>5.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>b. Hydrogen chloride (HCl)</ENT>
        <ENT>1.0E-2 lb/MWh</ENT>
        <ENT>For Method 26A, collect a minimum of 3 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT O="xl"/>
        <ENT>For ASTM D6348-03 <SU>2</SU> or Method 320, sample for a minimum of 1 hour.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl"/>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Sulfur dioxide (SO<E T="52">2</E>) <SU>3</SU>
        </ENT>
        <ENT>1.0 lb/MWh</ENT>
        <ENT>SO<E T="52">2</E> CEMS.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>c. Mercury (Hg)</ENT>
        <ENT>4.0E-2 lb/GWh</ENT>
        <ENT>Hg CEMS or sorbent trap monitoring system only.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">3. IGCC unit</ENT>
        <ENT>a. Filterable particulate matter (PM)</ENT>
        <ENT>7.0E-2 lb/MWh <SU>4</SU>
          <LI>9.0E-2 lb/MWh <SU>5</SU>
          </LI>
        </ENT>
        <ENT>Collect a minimum of 1 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Total non-Hg HAP metals</ENT>
        <ENT>4.0E-1 lb/GWh</ENT>
        <ENT>Collect a minimum of 1 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Individual HAP metals:</ENT>
        <ENT/>
        <ENT>Collect a minimum of 2 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Antimony (Sb)</ENT>
        <ENT>2.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Arsenic (As)</ENT>
        <ENT>2.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Beryllium (Be)</ENT>
        <ENT>1.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cadmium (Cd)</ENT>
        <ENT>2.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Chromium (Cr)</ENT>
        <ENT>4.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cobalt (Co)</ENT>
        <ENT>4.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Lead (Pb)</ENT>
        <ENT>9.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <PRTPAGE P="205"/>
        <ENT I="22"> </ENT>
        <ENT>Manganese (Mn)</ENT>
        <ENT>2.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Nickel (Ni)</ENT>
        <ENT>7.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Selenium (Se)</ENT>
        <ENT>3.0E-1 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>b. Hydrogen chloride (HCl)</ENT>
        <ENT>2.0E-3 lb/MWh</ENT>
        <ENT>For Method 26A, collect a minimum of 1 dscm per run; for Method 26, collect a minimum of 120 liters per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT O="xl"/>
        <ENT>For ASTM D6348-03 <SU>2</SU> or Method 320, sample for a minimum of 1 hour.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT/>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Sulfur dioxide (SO<E T="52">2</E>) <SU>3</SU>
        </ENT>
        <ENT>4.0E-1 lb/MWh</ENT>
        <ENT>SO<E T="52">2</E> CEMS.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>c. Mercury (Hg)</ENT>
        <ENT>3.0E-3 lb/GWh</ENT>
        <ENT>Hg CEMS or sorbent trap monitoring system only.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">4. Liquid oil-fired unit—continental (excluding limited-use liquid oil-fired subcategory units)</ENT>
        <ENT>a. Filterable particulate matter (PM)</ENT>
        <ENT>3.0E-1 lb/MWh <SU>1</SU>
        </ENT>
        <ENT>Collect a minimum of 1 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Total HAP metals</ENT>
        <ENT>2.0E-4 lb/MWh</ENT>
        <ENT>Collect a minimum of 2 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Individual HAP metals:</ENT>
        <ENT/>
        <ENT>Collect a minimum of 2 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Antimony (Sb)</ENT>
        <ENT>1.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Arsenic (As)</ENT>
        <ENT>3.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Beryllium (Be)</ENT>
        <ENT>5.0E-4 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cadmium (Cd)</ENT>
        <ENT>2.0E-4 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Chromium (Cr)</ENT>
        <ENT>2.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cobalt (Co)</ENT>
        <ENT>3.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Lead (Pb)</ENT>
        <ENT>8.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Manganese (Mn)</ENT>
        <ENT>2.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Nickel (Ni)</ENT>
        <ENT>9.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Selenium (Se)</ENT>
        <ENT>2.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Mercury (Hg)</ENT>
        <ENT>1.0E-4 lb/GWh</ENT>
        <ENT>For Method 30B sample volume determination (Section 8.2.4), the estimated Hg concentration should nominally be &lt;<SU>1/2</SU> the standard.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>b. Hydrogen chloride (HCl)</ENT>
        <ENT>4.0E-4 lb/MWh</ENT>
        <ENT>For Method 26A, collect a minimum of 3 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT O="xl"/>
        <ENT>For ASTM D6348-03 <SU>2</SU> or Method 320, sample for a minimum of 1 hour.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>c. Hydrogen fluoride (HF)</ENT>
        <ENT>4.0E-4 lb/MWh</ENT>
        <ENT>For Method 26A, collect a minimum of 3 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT O="xl"/>
        <ENT>For ASTM D6348-03 <SU>2</SU> or Method 320, sample for a minimum of 1 hour.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">5. Liquid oil-fired unit—non-continental (excluding limited-use liquid oil-fired subcategory units)</ENT>
        <ENT>a. Filterable particulate matter (PM)</ENT>
        <ENT>2.0E-1 lb/MWh <SU>1</SU>
        </ENT>
        <ENT>Collect a minimum of 1 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Total HAP metals</ENT>
        <ENT>7.0E-3 lb/MWh</ENT>
        <ENT>Collect a minimum of 1 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Individual HAP metals:</ENT>
        <ENT/>
        <ENT>Collect a minimum of 3 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Antimony (Sb)</ENT>
        <ENT>8.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Arsenic (As)</ENT>
        <ENT>6.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Beryllium (Be)</ENT>
        <ENT>2.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cadmium (Cd)</ENT>
        <ENT>2.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Chromium (Cr)</ENT>
        <ENT>2.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cobalt (Co)</ENT>
        <ENT>3.0E-1 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Lead (Pb)</ENT>
        <ENT>3.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Manganese (Mn)</ENT>
        <ENT>1.0E-1 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Nickel (Ni)</ENT>
        <ENT>4.1E0 lb/GWh</ENT>
      </ROW>
      <ROW>
        <PRTPAGE P="206"/>
        <ENT I="22"> </ENT>
        <ENT>Selenium (Se)</ENT>
        <ENT>2.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Mercury (Hg)</ENT>
        <ENT>4.0E-4 lb/GWh</ENT>
        <ENT>For Method 30B sample volume determination (Section 8.2.4), the estimated Hg concentration should nominally be &lt;<SU>1/2</SU> the standard.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>b. Hydrogen chloride (HCl)</ENT>
        <ENT>2.0E-3 lb/MWh</ENT>
        <ENT>For Method 26A, collect a minimum of 1 dscm per run; for Method 26, collect a minimum of 120 liters per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"> </ENT>
        <ENT O="xl"> </ENT>
        <ENT>For ASTM D6348-03 <SU>2</SU> or Method 320, sample for a minimum of 1 hour.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>c. Hydrogen fluoride (HF)</ENT>
        <ENT>5.0E-4 lb/MWh</ENT>
        <ENT>For Method 26A, collect a minimum of 3 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"> </ENT>
        <ENT O="xl"/>
        <ENT>For ASTM D6348-03 <SU>2</SU> or Method 320, sample for a minimum of 1 hour.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">6. Solid oil-derived fuel-fired unit</ENT>
        <ENT>a. Filterable particulate matter (PM)</ENT>
        <ENT>3.0E-2 lb/MWh <SU>1</SU>
        </ENT>
        <ENT>Collect a minimum of 1 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
        <ENT> </ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Total non-Hg HAP metals</ENT>
        <ENT>6.0E-1 lb/GWh</ENT>
        <ENT>Collect a minimum of 1 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT O="xl">OR</ENT>
        <ENT> </ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Individual HAP metals:</ENT>
        <ENT> </ENT>
        <ENT>Collect a minimum of 3 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Antimony (Sb)</ENT>
        <ENT>8.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Arsenic (As)</ENT>
        <ENT>3.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Beryllium (Be)</ENT>
        <ENT>6.0E-4 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cadmium (Cd)</ENT>
        <ENT>7.0E-4 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Chromium (Cr)</ENT>
        <ENT>6.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Cobalt (Co)</ENT>
        <ENT>2.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Lead (Pb)</ENT>
        <ENT>2.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Manganese (Mn)</ENT>
        <ENT>7.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Nickel (Ni)</ENT>
        <ENT>4.0E-2 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Selenium (Se)</ENT>
        <ENT>6.0E-3 lb/GWh</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>b. Hydrogen chloride (HCl)</ENT>
        <ENT>4.0E-4 lb/MWh</ENT>
        <ENT>For Method 26A, collect a minimum of 3 dscm per run.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT O="xl"/>
        <ENT>For ASTM D6348-03 <SU>2</SU> or Method 320, sample for a minimum of 1 hour.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl">OR</ENT>
        <ENT> </ENT>
        <ENT> </ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>Sulfur dioxide (SO<E T="52">2</E>) <SU>3</SU>
        </ENT>
        <ENT>1.0 lb/MWh</ENT>
        <ENT>SO<E T="52">2</E> CEMS.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT>c. Mercury (Hg)</ENT>
        <ENT>2.0E-3 lb/GWh</ENT>
        <ENT>Hg CEMS or Sorbent trap monitoring system only.</ENT>
      </ROW>
      <TNOTE>
        <SU>1</SU> Gross electric output.</TNOTE>
      <TNOTE>
        <SU>2</SU> Incorporated by reference, see § 63.14.</TNOTE>
      <TNOTE>
        <SU>3</SU> You may not use the alternate SO<E T="52">2</E> limit if your EGU does not have some form of FGD system (or, in the case of IGCC EGUs, some other acid gas removal system either upstream or downstream of the combined cycle block) and SO<E T="52">2</E> CEMS installed.</TNOTE>
      <TNOTE>
        <SU>4</SU> Duct burners on syngas; gross electric output.</TNOTE>
      <TNOTE>
        <SU>5</SU> Duct burners on natural gas; gross electric output.</TNOTE>
    </GPOTABLE>
    <CITA>[78 FR 24087, Apr. 24, 2013]</CITA>
  </APPENDIX>
</CFRGRANULE>