<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>40</CFRTITLE>
    <CFRTITLETEXT>Protection of Environment</CFRTITLETEXT>
    <VOL>15</VOL>
    <DATE>2015-07-01</DATE>
    <ORIGINALDATE>2015-07-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Applicability of General Provisions to Subpart PPPPP</TITLE>
    <GRANULENUM>7</GRANULENUM>
    <HEADING>Table 7 to Subpart PPPPP of Part 63</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="4">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER C" SEQ="2">AIR PROGRAMS (CONTINUED)</PARENT>
      <PARENT HEADING="PART 63" SEQ="1">NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED)</PARENT>
      <PARENT HEADING="Subpart PPPPP" SEQ="0">National Emission Standards for Hazardous Air Pollutants for Engine Test Cells/Stands</PARENT>
    </ANCESTORS>
  </FDSYS>
  <APPENDIX>
    <EAR>Pt. 63, Subpt. PPPPP, Table 7</EAR>
    <HD SOURCE="HED">Table 7 to Subpart PPPPP of Part 63—Applicability of General Provisions to Subpart PPPPP</HD>

    <P>As stated in 63.9365, you must comply with the General Provisions in §§ 63.1 through 63.15 that apply to you according to the following table:<PRTPAGE P="57"/>
    </P>
    <GPOTABLE CDEF="s50,r50,r50,r50" COLS="4" OPTS="L2">
      <BOXHD>
        <CHED H="1">Citation</CHED>
        <CHED H="1">Subject</CHED>
        <CHED H="1">Brief description</CHED>
        <CHED H="1">Applies to subpart PPPPP</CHED>
      </BOXHD>
      <ROW>
        <ENT I="01">§ 63.1(a)(1)</ENT>
        <ENT>Applicability</ENT>
        <ENT>General applicability of the General Provisions</ENT>
        <ENT>Yes. Additional terms defined in § 63.9375.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.1(a)(2)-(4)</ENT>
        <ENT>Applicability</ENT>
        <ENT>Applicability of source categories</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.1(a)(5)</ENT>
        <ENT>[Reserved]</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.1(a)(6)-(7)</ENT>
        <ENT>Applicability</ENT>
        <ENT>Contact for source category information; extension of compliance through early reduction</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.1(a)(8)</ENT>
        <ENT>Applicability</ENT>
        <ENT>Establishment of State rules or programs</ENT>
        <ENT>No. Refers to State programs.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.1(a)(9)</ENT>
        <ENT>[Reserved]</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.1(a)(10)-(14)</ENT>
        <ENT>Applicability</ENT>
        <ENT>Explanation of time periods, postmark deadlines</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.1(b)(1)</ENT>
        <ENT>Applicability</ENT>
        <ENT>Initial applicability</ENT>
        <ENT>Yes. Subpart PPPPP clarifies applicability at § 63.9285.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.1(b)(2)</ENT>
        <ENT>Applicability</ENT>
        <ENT>Title V operating permit-reference to part 70</ENT>
        <ENT>Yes. All major affected sources are required to obtain a Title V permit.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.1(b)(3)</ENT>
        <ENT>Applicability</ENT>
        <ENT>Record of applicability determination</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.1(c)(1)</ENT>
        <ENT>Applicability</ENT>
        <ENT>Applicability after standards are set</ENT>
        <ENT>Yes. Subpart PPPPP clarifies the applicability of each paragraph of subpart A to sources subject to subpart PPPPP.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.1(c)(2)</ENT>
        <ENT>Applicability</ENT>
        <ENT>Title V permit requirement for area sources</ENT>
        <ENT>No. Area sources are not subject to subpart PPPPP.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.1(c)(3)</ENT>
        <ENT>[Reserved]</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.1(c)(4)</ENT>
        <ENT>Applicability</ENT>
        <ENT>Extension of compliance for existing sources</ENT>
        <ENT>No. Existing sources are not covered by the substantive control requirements of subpart PPPPP.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.1(c)(5)</ENT>
        <ENT>Applicability</ENT>
        <ENT>Notification requirements for an area source becoming a major source</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.1(d)</ENT>
        <ENT>[Reserved]</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.1(e)</ENT>
        <ENT>Applicability</ENT>
        <ENT>Applicability of permit program before a relevant standard has been set</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.2</ENT>
        <ENT>Definitions</ENT>
        <ENT>Definitions for Part 63 standards</ENT>
        <ENT>Yes. Additional definitions are specified in § 63.9375.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.3</ENT>
        <ENT>Units and Abbreviations</ENT>
        <ENT>Units and abbreviations for Part 63 standards</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.4</ENT>
        <ENT>Prohibited Activities</ENT>
        <ENT>Prohibited activities; compliance date; circumvention, severability</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.5(a)</ENT>
        <ENT>Construction/Reconstruction</ENT>
        <ENT>Construction and reconstruction—applicability</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.5(b)(1)</ENT>
        <ENT>Construction/Reconstruction</ENT>
        <ENT>Requirements upon construction or reconstruction</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.5(b)(2)</ENT>
        <ENT O="xl">[Reserved].</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.5(b)(3)</ENT>
        <ENT>Construction/Reconstruction</ENT>
        <ENT>Approval of construction</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.5(b)(4)</ENT>
        <ENT>Construction/Reconstruction</ENT>
        <ENT>Notification of construction</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.5(b)(5)</ENT>
        <ENT>Construction/Reconstruction</ENT>
        <ENT>Compliance</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.5(b)(6)</ENT>
        <ENT>Construction/Reconstruction</ENT>
        <ENT>Addition of equipment</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.5(c)</ENT>
        <ENT O="xl">[Reserved]</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.5(d)</ENT>
        <ENT>Construction/Reconstruction</ENT>
        <ENT>Application for construction reconstruction</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.5(e)</ENT>
        <ENT>Construction/Reconstruction</ENT>
        <ENT>Approval of construction or reconstruction</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.5(f)</ENT>
        <ENT>Construction/Reconstruction</ENT>
        <ENT>Approval of construction or reconstruction based on prior State review</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.6(a)</ENT>
        <ENT>Applicability</ENT>
        <ENT>Applicability of standards and monitoring requirements</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.6(b)(1)-(2)</ENT>
        <ENT>Compliance Dates for New and Reconstructed Sources</ENT>
        <ENT>Standards apply at effective date; 3 years after effective date; upon startup; 10 years after construction or reconstruction commences for 112(f)</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <PRTPAGE P="58"/>
        <ENT I="01">§ 63.6(b)(3)</ENT>
        <ENT>Compliance Dates for New and Reconstructed Sources</ENT>
        <ENT>Compliance dates for sources constructed or reconstructed before effective date</ENT>
        <ENT>No. Compliance is required by startup or effective date.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.6(b)(4)</ENT>
        <ENT>Compliance Dates for New and Reconstructed Sources</ENT>
        <ENT>Compliance dates for sources also subject to § 112(f) standards</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.6(b)(5)</ENT>
        <ENT>Compliance Dates for New and Reconstructed Sources</ENT>
        <ENT>Notification</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.6(b)(6)</ENT>
        <ENT O="xl">[Reserved].</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.6(b)(7)</ENT>
        <ENT>Compliance Dates for New and Reconstructed Sources</ENT>
        <ENT>Compliance dates for new and reconstructed area sources that become major</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.6(c)(1)-(2)</ENT>
        <ENT>Compliance Dates for Existing Sources</ENT>
        <ENT>Effective date establishes compliance date</ENT>
        <ENT>No. Existing sources are not covered by the substantive control requirements of subpart PPPPP.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.6(c)(3)-(4)</ENT>
        <ENT O="xl">[Reserved].</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.6(c)(5)</ENT>
        <ENT>Compliance Dates for Existing Sources</ENT>
        <ENT>Compliance dates for existing area sources that becomes major</ENT>
        <ENT>Yes. If the area source become a major source by addition or reconstruction, the added or reconstructed portion will be subject to subpart PPPPP.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.6(d)</ENT>
        <ENT O="xl">[Reserved].</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.6(e)(1)-(2)</ENT>
        <ENT>Operation and Maintenance Requirements</ENT>
        <ENT>Operation and maintenance</ENT>
        <ENT>Yes. Except that you are not required to have an SSMP for control devices and associated monitoring equipment.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.6(e)(3)</ENT>
        <ENT>SSMP</ENT>
        <ENT>1. Requirement for SSM and SSMP<LI O="xl">2. Content of SSMP.</LI>
        </ENT>
        <ENT>Yes. You must develop an SSMP for each control device and associated monitoring equipment.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.6(f)(1)</ENT>
        <ENT>Compliance Except During SSM</ENT>
        <ENT>You must comply with emission standards at all times except during SSM of control devices or associated monitoring equipment</ENT>
        <ENT>Yes, but you must comply with emission standards at all times except during SSM of control devices and associated monitoring equipment only.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.6(f)(2)-(3)</ENT>
        <ENT>Methods for Determining Compliance</ENT>
        <ENT>Compliance based on performance test, operation and maintenance plans, records, inspection</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.6(g)(1)-(3)</ENT>
        <ENT>Alternative Standard</ENT>
        <ENT>Procedures for getting an alternative standard</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.6(h)</ENT>
        <ENT>Opacity/Visible Emission (VE) Standards</ENT>
        <ENT>Requirements for opacity/VE standards</ENT>
        <ENT>No. Subpart PPPPP does not establish opacity/VE standards and does not require continuous opacity monitoring systems (COMS).</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.6(i)(1)-(14)</ENT>
        <ENT>Compliance Extension</ENT>
        <ENT>Procedures and criteria for Administrator to grant compliance extension</ENT>
        <ENT>No. Compliance extension provisions apply to existing sources, which do not have emission limitations in subpart PPPPP.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.6(j)</ENT>
        <ENT>Presidential Compliance Exemption</ENT>
        <ENT>President may exempt source category from requirement to comply with rule</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.7(a)(1)-(2)</ENT>
        <ENT>Performance Test Dates</ENT>
        <ENT>Dates for conducting initial performance testing and other compliance demonstrations: Must conduct within 180 days after first subject to rule</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.7(a)(3)</ENT>
        <ENT>Section 114 Authority</ENT>
        <ENT>Administrator may require a performance test under CAA Section 114 at any time</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.7(b)(1)</ENT>
        <ENT>Notification Performance Test</ENT>
        <ENT>Must notify Administrator 60 days before the test</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <PRTPAGE P="59"/>
        <ENT I="01">§ 63.7(b)(2)</ENT>
        <ENT>Notification of Rescheduling</ENT>
        <ENT>If have to reschedule performance test, must notify Administrator 5 days before schedule date of rescheduled date</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.7(c)</ENT>
        <ENT>Quality Assurance/Test Plan</ENT>
        <ENT>1. Requirement to submit site-specific test plan 60 days before the test or on date Administrator agrees with</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>2. Test plan approval procedures</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>3. Performance audit requirements</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>4. Internal and external QA procedures for testing</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.7(d)</ENT>
        <ENT>Testing Facilities</ENT>
        <ENT>Requirements for testing facilities</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.7(e)(1)</ENT>
        <ENT>Conditions for Conducting Performance Tests</ENT>
        <ENT>Performance tests must be conducted under representative conditions; cannot conduct performance tests during SSM; not a violation to exceed standard during SSM</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.7(e)(2)</ENT>
        <ENT>Conditions for Conducting Performance Tests</ENT>
        <ENT>Must conduct according to rule and EPA test methods unless Administrator approves alternative</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.7(e)(3)</ENT>
        <ENT>Test Run Duration</ENT>
        <ENT>1. Must have three test runs of at least 1 hour each</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>2. Compliance is based on arithmetic mean of three runs</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>3. Conditions when data from an additional test run can be used</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.7(e)(4)</ENT>
        <ENT>Other Performance Testing</ENT>
        <ENT>Administrator may require other testing under section 114 of the CAA</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.7(f)</ENT>
        <ENT>Alternative Test Method</ENT>
        <ENT>Procedures by which Administrator can grant approval to use an alternative test method</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.7(g)</ENT>
        <ENT>Performance Test Data Analysis</ENT>
        <ENT>1. Must include raw data in performance test report</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>2. Must submit performance test data 60 days after end of test with the Notification of Compliance Status</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>3. Keep data for 5 years</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.7(h)</ENT>
        <ENT>Waiver of Tests</ENT>
        <ENT>Procedures for Administrator to waive performance test</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.8(a)(1)</ENT>
        <ENT>Applicability of Monitoring Requirements</ENT>
        <ENT>Subject to all monitoring requirements in standard</ENT>
        <ENT>Yes. Subpart PPPPP contains specific requirements for monitoring at § 63.9325.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.8(a)(2)</ENT>
        <ENT>Performance Specifications</ENT>
        <ENT>Performance Specifications in appendix B of part 60 apply</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.8(a)(3)</ENT>
        <ENT O="xl">[Reserved]</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.8(a)(4)</ENT>
        <ENT>Monitoring with Flares</ENT>
        <ENT>Unless your rule says otherwise, the requirements for flares in 63.11 apply</ENT>
        <ENT>No. Subpart PPPPP does not have monitoring requirements for flares.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.8(b)(1)</ENT>
        <ENT>Monitoring</ENT>
        <ENT>Must conduct monitoring according to standard unless Administrator approves alternative</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.8(b)(2)-(3)</ENT>
        <ENT>Multiple Effluents and Multiple Monitoring Systems</ENT>
        <ENT>1. Specific requirements for installing monitoring systems</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <PRTPAGE P="60"/>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>2. Must install on each effluent before it is combined and before it is released to the atmosphere unless Administrator approves otherwise</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>3. If more than one monitoring system on an emission point, must report all monitoring system results, unless one monitoring system is a backup</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.8(c)(1)</ENT>
        <ENT>Monitoring System Operation and Maintenance</ENT>
        <ENT>Maintain monitoring system in a manner consistent with good air pollution control practices</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.8(c)(1)(i)</ENT>
        <ENT>Routine and predictable CMS malfunctions</ENT>
        <ENT>1. Keep parts for routine repairs of CMS readily available<LI>2. Reporting requirements for SSM when action is described in SSMP</LI>
        </ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>3. Reporting requirements for SSM when action is described in SSMP</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.8(c)(1)(ii)</ENT>
        <ENT>SSM of CMS Not in SSMP</ENT>
        <ENT>Reporting requirements for SSM of CMS when action is not described in SSMP</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.8(c)(1)(iii)</ENT>
        <ENT>Compliance with Operation and Maintenance Requirements</ENT>

        <ENT>1. How Administrator determines if source complying with operation and maintenance requirements<LI O="xl">2. Review of source O&amp;M procedures, records, manufacturer's instructions and recommendations, and inspection</LI>
        </ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.8(c)(2)-(3)</ENT>
        <ENT>Monitoring System Installation</ENT>
        <ENT>1. Must install to get representative emission of parameter measurements</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>2. Must verify operational status before or at performance test</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.8(c)(4)</ENT>
        <ENT>Continuous Monitoring System (CMS) Requirements</ENT>
        <ENT>1. CMS must be operating except during breakdown, out of control, repair, maintenance, and high-level calibration drifts</ENT>
        <ENT>No. Follow specific requirements in § 63.9335(a) and (b) of subpart PPPPP.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>2. COMS must have a minimum of one cycle of sampling and analysis for each successive 10-second period and one cycle of data recording for each successive 6-minute period</ENT>
        <ENT>No. Follow specific requirements in § 63.9335(a) and (b) of subpart PPPP.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>3. CEMS must have a minimum of one cycle of operation for each successive 15-minute period</ENT>
        <ENT>No. Follow specific requirements in § 63.9335(a) and (b) of subpart PPPPP.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.8(c)(5)</ENT>
        <ENT>COMS Minimum Procedures</ENT>
        <ENT>COMS minimum procedures</ENT>
        <ENT>No. Subpart PPPPP does not have opacity/VE standards.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.8(c)(6)-(8)</ENT>
        <ENT>CMS Requirements</ENT>
        <ENT>Zero and high-level calibration check requirements, out-of-control periods</ENT>
        <ENT>Yes. Except that PPPP does not require COMS.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.8(d)</ENT>
        <ENT>CMS Quality Control</ENT>
        <ENT>1. Requirements for CMS quality control, including calibration, etc</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>2. Must keep quality control plan on record for 5 years. Keep old versions for 5 years after revisions</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.8(e)</ENT>
        <ENT>CMS Performance Evaluation</ENT>
        <ENT>Notification, performance evaluation test plan, reports</ENT>
        <ENT>Yes. Except for § 63.8(e)(5)(ii), which applies to COMS.</ENT>
      </ROW>
      <ROW>
        <PRTPAGE P="61"/>
        <ENT I="01">§ 63.8(f)(1)-(5)</ENT>
        <ENT>Alternative Monitoring Method</ENT>
        <ENT>Procedures for Administrator to approve alternative monitoring</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.8(f)(6)</ENT>
        <ENT>Alternative to Relative Accuracy Test</ENT>
        <ENT>Procedures for Administrator to approve alternative relative accuracy tests for CEMS</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.8(g)</ENT>
        <ENT>Data Reduction</ENT>

        <ENT>1. COMS 6-minute averages calculated over at least 36 evenly spaced data points<LI O="xl">2. CEMS 1-hour averages computed over at least 4 equally spaced data points</LI>
        </ENT>
        <ENT>Yes. Except that provisions for COMS are not applicable. Averaging periods for demonstrating compliance are specified at § 63.9340.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.8(g)(5)</ENT>
        <ENT>Data Reduction</ENT>
        <ENT>Data that cannot be used in computing averages for CEMS and COMS</ENT>
        <ENT>No. Specific language is located at § 63.9335(a).</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.9(a)</ENT>
        <ENT>Notification Requirements</ENT>
        <ENT>Applicability and State delegation</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.9(b)(1)-(5)</ENT>
        <ENT>Initial Notifications</ENT>
        <ENT>1. Submit notification subject 120 days after effective date</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>2. Notification of intent to construct/ reconstruct; notification of commencement of construct/ reconstruct; notification of startup</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>3. Contents of each</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.9(c)</ENT>
        <ENT>Request for Compliance Extension</ENT>
        <ENT>Can request if cannot comply by date or if installed BACT/LAER</ENT>
        <ENT>No. Compliance extensions do not apply to new or reconstructed sources.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.9(d)</ENT>
        <ENT>Notification of Special Compliance Requirements for New Source</ENT>
        <ENT>For sources that commence construction between proposal and promulgation and want to comply 3 years after effective date</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.9(e)</ENT>
        <ENT>Notification of Performance Test</ENT>
        <ENT>Notify Administrator 60 days prior</ENT>
        <ENT>No. Subpart PPPPP does not require performance testing.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.9(f)</ENT>
        <ENT>Notification of Opacity/VE Test</ENT>
        <ENT>Notify Administrator 30 days prior</ENT>
        <ENT>No. Subpart PPPPP does not have opacity/VE standards.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.9(g)(1)</ENT>
        <ENT>Additional Notifications when Using CMS</ENT>
        <ENT>Notification of performance evaluation</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.9(g)(2)</ENT>
        <ENT>Additional Notifications when Using CMS</ENT>
        <ENT>Notification of use of COMS data</ENT>
        <ENT>No. Subpart PPPPP does not contain opacity or VE standards.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.9(g)(3)</ENT>
        <ENT>Additional Notifications when Using CMS</ENT>
        <ENT>Notification that exceeded criterion for relative accuracy</ENT>
        <ENT>Yes. If alternative is in use.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.9(h)(1)-(6)</ENT>
        <ENT>Notification of Compliance Status</ENT>
        <ENT>1. Contents</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>2. Due 60 days after end of performance test or other compliance demonstration, except for opacity/VE, which are due 30 days after</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>3. When to submit to Federal vs. State authority</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.9(i)</ENT>
        <ENT>Adjustment of Submittal Deadlines</ENT>
        <ENT>Procedures for Administrator to approve change in when notifications must be submitted</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.9(j)</ENT>
        <ENT>Change in Previous Information</ENT>
        <ENT>Must submit within 15 days after the change</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.10(a)</ENT>
        <ENT>Recordkeeping/Reporting</ENT>
        <ENT>1. Applies to all, unless compliance extension</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>2. When to submit to Federal vs. State authority</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>3. Procedures for owners of more than one source</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.10(b)(1)</ENT>
        <ENT>Recordkeeping/Reporting</ENT>
        <ENT>1. General requirements</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>2. Keep all records readily available</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>3. Keep for 5 years</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.10(b)(2)(i)-(v)</ENT>
        <ENT>Records Related to SSM</ENT>
        <ENT>1. Occurrence of each of operation (process equipment)</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <PRTPAGE P="62"/>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>2. Occurrence of each malfunction of air pollution equipment</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>3. Maintenance on air pollution control equipment</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>4. Actions during SSM</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="22"> </ENT>
        <ENT O="xl"/>
        <ENT>5. All information necessary to demonstrate conformance with the SSMP</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.10(b)(2)(vi)-(xi)</ENT>
        <ENT>CMS Records</ENT>
        <ENT>Malfunctions, inoperative, out of control</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.10(b)(2)(xii)</ENT>
        <ENT>Records</ENT>
        <ENT>Records when under waiver</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.10(b)(2)(xiii)</ENT>
        <ENT>Records</ENT>
        <ENT>Records when using alternative to relative accuracy test</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.10(b)(2)(xiv)</ENT>
        <ENT>Records</ENT>
        <ENT>All documentation supporting initial notification and notification of compliance status</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.10(b)(3)</ENT>
        <ENT>Records</ENT>
        <ENT>Applicability determinations</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.10(c)(1)-(6), (9)-(15)</ENT>
        <ENT>Records</ENT>
        <ENT>Additional records for CEMS</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.10(c)(7)-(8)</ENT>
        <ENT>Records</ENT>
        <ENT>Records of excess emissions and parameter monitoring exceedances for CMS</ENT>
        <ENT>No. Specific language is located at § 63.9355 of subpart PPPPP.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.10(d)(1)</ENT>
        <ENT>General Reporting Requirements</ENT>
        <ENT>Requirement to report</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.10(d)(2)</ENT>
        <ENT>Report of Performance Test Results</ENT>
        <ENT>When to submit to Federal or State authority</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.10(d)(3)</ENT>
        <ENT>Reporting Opacity or VE Observations</ENT>
        <ENT>What to report and when</ENT>
        <ENT>No. Subpart PPPPP does not have opacity/VE standards.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.10(d)(4)</ENT>
        <ENT>Progress Reports</ENT>
        <ENT>Must submit progress reports on schedule if under compliance extension</ENT>
        <ENT>No. Compliance extensions do not apply to new or reconstructed sources.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.10(d)(5)</ENT>
        <ENT>SSM Reports</ENT>
        <ENT>Contents and submission</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.10(e)(1) and (2)(i)</ENT>
        <ENT>Additional CMS Reports</ENT>
        <ENT>Additional CMS reports</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.10(e)(2)(ii)</ENT>
        <ENT>Additional CMS Reports</ENT>
        <ENT>COMS-related report</ENT>
        <ENT>No. Subpart PPPPP does not require COMS.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.10(e)(3)</ENT>
        <ENT>Additional CMS Reports</ENT>
        <ENT>Excess emissions and parameter exceedances reports</ENT>
        <ENT>No. Specific language is located in § 63.9350 of subpart PPPPP.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.10(e)(4)</ENT>
        <ENT>Additional CMS Reports</ENT>
        <ENT>Reporting COMS data</ENT>
        <ENT>No. Subpart PPPPP does not require COMS.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.10(f)</ENT>
        <ENT>Waiver for Recordkeeping/Reporting</ENT>
        <ENT>Procedures for Administrator to waive</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.11</ENT>
        <ENT>Control Device Requirements</ENT>
        <ENT>Requirements for flares</ENT>
        <ENT>No. Subpart PPPPP does not specify use of flares for compliance.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.12</ENT>
        <ENT>State Authority and Delegations</ENT>
        <ENT>State authority to enforce standards</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.13</ENT>
        <ENT>Addresses of State Air Pollution Control Offices and EPA Regional Offices</ENT>
        <ENT>Addresses where reports, notifications, and requests are sent</ENT>
        <ENT>Yes.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.14</ENT>
        <ENT>Incorporations by Reference</ENT>
        <ENT>Test methods incorporated by reference</ENT>
        <ENT>Yes. ASTM D 6522-00 and ANSI/ASME PTC 19.10-1981 (incorporated by reference-See § 63.14).</ENT>
      </ROW>
      <ROW>
        <ENT I="01">§ 63.15</ENT>
        <ENT>Availability of Information and Confidentiality</ENT>
        <ENT>Public and confidential information</ENT>
        <ENT>Yes.</ENT>
      </ROW>
    </GPOTABLE>
    <CITA>[68 FR 28785, May 27, 2003, as amended at 71 FR 20470, Apr. 20, 2006]</CITA>
  </APPENDIX>
</CFRGRANULE>