<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>30</CFRTITLE>
    <CFRTITLETEXT>Mineral Resources</CFRTITLETEXT>
    <VOL>3</VOL>
    <DATE>2014-07-01</DATE>
    <ORIGINALDATE>2014-07-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>How to calculate excess moisture in LOW-rank coals.</TITLE>
    <GRANULENUM>Â§ 870.20</GRANULENUM>
    <HEADING>Section Â§ 870.20</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 30" SEQ="3">Mineral Resources</PARENT>
      <PARENT HEADING="CHAPTER VII" SEQ="2">OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR</PARENT>
      <PARENT HEADING="SUBCHAPTER R" SEQ="1">ABANDONED MINE LAND RECLAMATION</PARENT>
      <PARENT HEADING="PART 870" SEQ="0">ABANDONED MINE RECLAMATION FUND-FEE COLLECTION AND COAL PRODUCTION REPORTING</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 870.20</SECTNO>
    <SUBJECT>How to calculate excess moisture in LOW-rank coals.</SUBJECT>

    <P>Here are the requirements for calculating the excess moisture in low-rank coals for a calendar quarter. ASTM standards D2234-89, <E T="03">Standard Test Methods for Collection of a Gross Sample of Coal;</E> D3302-91, <E T="03">Standard Test Method for Total Moisture in Coal;</E> and, D1412-93, <E T="03">Standard Test Method for Equilibrium Moisture of Coal at 96 to 97 Percent Relative Humidity and 30 °C</E> are incorporated by reference as published in the 1994 Annual Book of ASTM Standards, Volume 05.05. The Director of the Federal Register approved this incorporation by reference in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Each applicable ASTM standard is incorporated as it exists on the date of the approval, and a notice of any change in it will be published in the <E T="04">Federal Register.</E> You may obtain copies from the ASTM, 100 Barr Harbor Drive, West Conshohocken, Pennsylvania 19428. A copy of the ASTM standards is available for inspection at the Office of Surface Mining Reclamation and Enforcement, Administrative Record, Room 101, 1951 Constitution Avenue, NW., <PRTPAGE P="421"/>Washington, DC, or at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: <E T="03">http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html.</E>
    </P>
    <P>(a)(1) Calculate the excess moisture percentage using one of these equations:</P>
    <GPH DEEP="56" SPAN="1">
      <GID>ER06NO97.003</GID>
    </GPH>
    <P>(2) EM equals excess moisture percentage. TM equals total as-shipped moisture percentage calculated according to Table 1 of this section. IM equals inherent moisture percentage calculated according to Tables 2 and 3 of this section.</P>
    <P>(b) Multiply the excess moisture percentage by the tonnage from the bona fide sales, transfers of ownership, or uses by the operator during the quarter.</P>
    <GPH DEEP="194" SPAN="2">
      <GID>ER06No97.004</GID>
    </GPH>
    <GPH DEEP="160" SPAN="2">
      <PRTPAGE P="422"/>
      <GID>ER06NO97.005</GID>
    </GPH>
    <GPH DEEP="231" SPAN="2">
      <GID>ER06NO97.006</GID>
    </GPH>
    <CITA>[62 FR 60146, Nov. 6, 1997, as amended at 75 FR 60276, Sept. 29, 2010]</CITA>
  </SECTION>