    <COVERONLY>false</COVERONLY>
    <TITLE>Engine exhaust cooling.</TITLE>
    <GRANULENUM>182.425</GRANULENUM>
    <HEADING>Section 182.425</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 46" SEQ="4">Shipping</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER T" SEQ="2">SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS)</PARENT>
      <PARENT HEADING="PART 182" SEQ="1">MACHINERY INSTALLATION</PARENT>
      <PARENT HEADING="Subpart D" SEQ="0">Specific Machinery Requirements</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 182.425</SECTNO>
    <SUBJECT>Engine exhaust cooling.</SUBJECT>
    <P>(a) Except as otherwise provided in this paragraph, all engine exhaust pipes must be water cooled.</P>
    <P>(1) Vertical dry exhaust pipes are permissible if installed in compliance with §§ 177.405(b) and 177.970 of this chapter.</P>
    <P>(2) Horizontal dry exhaust pipes are permitted only if:</P>
    <P>(i) They do not pass through living or berthing spaces;</P>
    <P>(ii) They terminate above the deepest load waterline;</P>
    <P>(iii) They are so arranged as to prevent entry of cold water from rough or boarding seas;</P>
    <P>(iv) They are constructed of corrosion resisting material at the hull penetration; and</P>
    <P>(v) They are installed in compliance with §§ 177.405(b) and 177.970 of this chapter.</P>
    <P>(b) The exhaust pipe cooling water system must comply with the requirements of this paragraph.</P>
    <P>(1) Water for cooling the exhaust pipe must be obtained from the engine cooling water system or a separate engine driven pump.</P>

    <P>(2) Water for cooling the exhaust pipe, other than a vertical exhaust, must be injected into the exhaust system as near to the engine manifold as practicable. The water must pass through the entire length of the exhaust pipe.<PRTPAGE P="262"/>
    </P>
    <P>(3) The part of the exhaust system between the point of cooling water injection and the engine manifold must be water-jacketed or effectively insulated and protected in compliance with §§ 177.405(b) and 177.970 of this chapter.</P>
    <P>(4) Vertical exhaust pipes must be water-jacketed or suitably insulated as required by § 182.430(g).</P>
    <P>(5) When the exhaust cooling water system is separate from the engine cooling water system, a suitable warning device, visual or audible, must be installed at the operating station to indicate any reduction in normal water flow in the exhaust cooling system.</P>
    <P>(6) A suitable hull strainer must be installed in the circulating raw water intake line for the exhaust cooling system.</P>
    <P>(c) Engine exhaust cooling system built in accordance with the requirements of ABYC P-1 (incorporated by reference; see 46 CFR 175.600) will be considered as meeting the requirements of this section.</P>
    <CITA>[CGD 85-080, 61 FR 986, Jan. 10, 1996; 61 FR 20557, May 7, 1996, as amended by USCG-2003-16630, 73 FR 65207, Oct. 31, 2008]</CITA>