<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>46</CFRTITLE>
    <CFRTITLETEXT>Shipping</CFRTITLETEXT>
    <VOL>2</VOL>
    <DATE>2013-10-01</DATE>
    <ORIGINALDATE>2013-10-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Piping for instruments, control, and sampling (modifies 122.3).</TITLE>
    <GRANULENUM>56.50-97</GRANULENUM>
    <HEADING>Section 56.50-97</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 46" SEQ="4">Shipping</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER F" SEQ="2">MARINE ENGINEERING</PARENT>
      <PARENT HEADING="PART 56" SEQ="1">PIPING SYSTEMS AND APPURTENANCES</PARENT>
      <PARENT HEADING="Subpart 56.50" SEQ="0">Design Requirements Pertaining to Specific Systems</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <PRTPAGE P="215"/>
    <SECTNO>§ 56.50-97</SECTNO>
    <SUBJECT>Piping for instruments, control, and sampling (modifies 122.3).</SUBJECT>
    <P>(a) Piping for instruments, control, and sampling must comply with paragraph 122.3 of ASME B31.1 (incorporated by reference; see 46 CFR 56.01-2) except that:</P>
    <P>(1) Soldered type fittings may not be used.</P>
    <P>(2) The outside diameter of takeoff connections may not be less than 0.840 inches for service conditions up to 900 psi or 800 °F., and 1.050 inches for conditions that exceed either of these limits.</P>
    <CITA>[CGFR 68-82, 33 FR 18843, Dec. 18, 1968, as amended by CGFR 69-127, 35 FR 9978, June 17, 1970; CGD 73-254, 40 FR 40165, Sept. 2, 1975; USCG-2003-16630, 73 FR 65178, Oct. 31, 2008]</CITA>
  </SECTION>
</CFRGRANULE>