    <TITLE>Wiring methods and materials.</TITLE>
    <GRANULENUM>28.370</GRANULENUM>
    <HEADING>Section 28.370</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 46" SEQ="4">Shipping</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">COAST GUARD, DEPARTMENT OF HOMELAND SECURITY</PARENT>
      <PARENT HEADING="SUBCHAPTER C" SEQ="2">UNINSPECTED VESSELS</PARENT>
      <PARENT HEADING="PART 28" SEQ="1">REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS</PARENT>
      <PARENT HEADING="Subpart D" SEQ="0">Requirements for Vessels Which Have Their Keel Laid or Are at a Similar Stage of Construction on or After or Which Undergo a Major Conversion Completed on or After September 15, 1991, and That Operate With More Than 16 Individuals on Board</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 28.370</SECTNO>
    <SUBJECT>Wiring methods and materials.</SUBJECT>
    <P>(a) All cable and wire must have insulated, stranded copper conductors of the appropriate size and voltage rating for the circuit.</P>

    <P>(b) Each conductor must be No. 22 AWG or larger. Conductors in power and lighting circuits must be No. 14 AWG or larger. Conductors must be <PRTPAGE P="329"/>sized so that the voltage drop at the load terminals is not more than 10 percent.</P>
    <P>(c) Cable and wiring not serving equipment in a high risk fire area such as a galley, laundry, or machinery space must be routed as far as practicable from these spaces. As far as practicable, cables serving duplicated essential equipment must be separated so that a casualty that affects one cable does not affect the other.</P>
    <P>(d) Cable and wire for power and lighting circuits must:</P>
    <P>(1) For circuits of less than 50 volts, meet 33 CFR 183.425 and 183.430; and</P>
    <P>(2) For circuits of 50 volts or greater:</P>
    <P>(i) Meet sections 310-13 and 310-15 of NFPA 70, except that asbestos insulated cable and dry location cable must not be used;</P>
    <P>(ii) Be listed by Underwriters Laboratories Inc. as UL Boat or UL Marine Shipboard cable; or</P>
    <P>(iii) Meet 46 CFR part 111, subpart 111.60.</P>
    <P>(e) All metallic cable armor must be electrically continuous and grounded to the metal hull or the common ground point at each end of the cable run, except that final sub-circuits (those supplying loads) may be grounded at the supply end only.</P>
    <P>(f) A wiring termination and connection must be made in a fire retardant enclosure such as a junction box, fixture enclosure, or panel enclosure. A fire retardant plastic enclosure is acceptable.</P>