    <TITLE>Cooking systems on vessels carrying passengers for hire.</TITLE>
    <GRANULENUM>25.45-2</GRANULENUM>
    <HEADING>Section 25.45-2</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 46" SEQ="4">Shipping</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">COAST GUARD, DEPARTMENT OF HOMELAND SECURITY</PARENT>
      <PARENT HEADING="SUBCHAPTER C" SEQ="2">UNINSPECTED VESSELS</PARENT>
      <PARENT HEADING="PART 25" SEQ="1">REQUIREMENTS</PARENT>
      <PARENT HEADING="Subpart 25.45" SEQ="0">Cooking, Heating, and Lighting Systems</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 25.45-2</SECTNO>
    <SUBJECT>Cooking systems on vessels carrying passengers for hire.</SUBJECT>
    <P>(a) No fuel may be used in any cooking system on any vessel carrying passengers for hire without the approval of Commandant (G-MSE) except those listed in § 25.45-1, subject to the requirements stated therein, and liquefied petroleum gas (LPG), or compressed natural gas (CNG).</P>
    <P>(b) Cooking systems using LPG or CNG must meet the following requirements:</P>
    <P>(1) The design, installation, and testing of each LPG system must meet ABYC A-1-78 or chapter 6 of NFPA 302.</P>
    <P>(2) The design, installation, and testing of each CNG system must meet ABYC A-22-78 or chapter 6 of NFPA 302.</P>
    <P>(3) Cooking systems using chapter 6 of NFPA 302 as the standard must meet the following additional requirements:</P>
    <P>(i) The storage or use of CNG containers within the accommodation area, machinery spaces, bilges, or other enclosed spaces is prohibited.</P>
    <P>(ii) LPG or CNG must be odorized in accordance with ABYC A-1.5.d or A-22.5.b, respectively.</P>
    <P>(iii) The marking and mounting of LPG cylinders must be in accordance with ABYC A-1.6.b.</P>
    <P>(iv) LPG cylinders must be of the vapor withdrawal type as specified in ABYC A-1.5.b.</P>
    <P>(4) Continuous pilot lights or automatic glow plugs are prohibited for an LPG or CNG installation using ABYC A-1 or A-22 as the standard.</P>

    <P>(5) CNG installations using ABYC A-22 as the standard must meet the following additional requirements:<PRTPAGE P="319"/>
    </P>
    <P>(i) The stowage or use of CNG containers within the accommodation area, machinery spaces, bilges, or other enclosed spaces is prohibited.</P>
    <P>(ii) The CNG cylinders, regulating equipment, and safety equipment must meet the installation, stowage, and testing requirements specified in paragraph 6-5.12 of NFPA 302.</P>
    <P>(iii) The use of stowage of stoves with attached CNG cylinders is prohibited as specified in paragraph 6-5.1 of NFPA 302.</P>
    <P>(6) If the fuel supply line of an LPG or CNG system enters an enclosed space on the vessel, a remote shut-off valve must be installed that can be operated from a position adjacent to the appliance. The valve must be located between the fuel tank and the point where the fuel supply line enters the enclosed portion of the vessel. A power operated valve installed to meet this requirement must be of a type that will fail closed.</P>
    <P>(7) The following variances from ABYC A-1.11.b(1) are allowed for CNG:</P>
    <P>(i) The storage locker or housing access opening need not be in the top.</P>
    <P>(ii) The locker or housing need not be above the waterline.</P>
    <P>(8) The following variances from NFPA 302 are allowed:</P>
    <P>(i) The storage locker or housing for CNG tank installations need not be above the waterline as required by paragraph 6-5.12.1.1(a).</P>

    <P>(ii) Ignition protection need not be provided as required by paragraph 6-5.4.
    </P>
    <NOTE>
      <HD SOURCE="HED">Note to § 25.45-2:</HD>
      <P>The ABYC and NFPA standards referenced in this section require the posting of placards containing safety precautions for gas cooking systems.</P>
    </NOTE>
    <CITA>[CGD 83-013, 54 FR 6402, Feb. 10, 1989, as amended by CGD 83-013, 55 FR 3960, Feb. 6, 1990; CGD 95-072, 60 FR 50461, Sept. 29, 1995; CGD 96-041, 61 FR 50726, Sept. 27, 1996; USCG-2000-7790, 65 FR 58458, Sept. 29, 2000]</CITA>