[Title 40 CFR C]
[Code of Federal Regulations (annual edition) - July 1, 2002 Edition]
[Title 40 - PROTECTION OF ENVIRONMENT]
[Chapter I - ENVIRONMENTAL PROTECTION AGENCY]
[Subchapter C - AIR PROGRAMS (CONTINUED)]
[Part 59 - NATIONAL VOLATILE ORGANIC COMPOUND EMISSION STANDARDS FOR CONSUMER AND COMMERCIAL PRODUCTS]
[Subpart C - National Volatile Organic Compound Emission Standards for]
[From the U.S. Government Printing Office]


40PROTECTION OF ENVIRONMENT52002-07-012002-07-01falseNational Volatile Organic Compound Emission Standards forCSubpart CPROTECTION OF ENVIRONMENTENVIRONMENTAL PROTECTION AGENCYAIR PROGRAMS (CONTINUED)NATIONAL VOLATILE ORGANIC COMPOUND EMISSION STANDARDS FOR CONSUMER AND COMMERCIAL PRODUCTS
  Subpart C--National Volatile Organic Compound Emission Standards for 
                            Consumer Products

    Source: 63 FR 48831, Sept. 11, 1998, unless other noted.



Sec. 59.201  Applicability and designation of regulated entity.

    (a) The provisions of the subpart apply to consumer products 
manufactured or imported on or after December 10, 1998 for sale or 
distribution in the United States.
    (b) The regulated entity is: the manufacturer or importer of the 
product; and any distributor that is named on the product label. The 
manufacturer or importer of the product is a regulated entity for 
purposes of compliance with the volatile organic compounds (VOC) content 
or emission limits in Sec. 49.203, regardless of whether the 
manufacturer or importer is named on the label or not. The distributor, 
if named on the label, is the regulated entity for purposes of 
compliance with all sections of this part except for Sec. 59.203. 
Distributors whose names do not appear on the label are not regulated 
entities. If no distributor is named on the label, then the manufacturer 
or importer is responsible for compliance with all sections of this 
part.
    (c) The provisions of this subpart do not apply to consumer products 
that meet the criteria specified in paragraph (c)(1) through (c)(7) of 
this section.
    (1) Any consumer product manufacturer in the United States for 
shipment and use outside of the United States.
    (2) Insecticides and air fresheners containing at least 98-percent 
paradichlorobenzene or at least 98-percent naphthalene.
    (3) Adhesives sold in containers of 0.03 liter (1 ounce) or less.
    (4) Bait station insecticides. For the purpose of this subpart, bait 
station insecticides are containers enclosing an insecticidal bait that 
does not weigh more than 14 grams (0.5 ounce), where

[[Page 299]]

bait is designed to be ingested by insects and is composed of solid 
material feeding stimulants with less than 5-percent by weight active 
ingredients.
    (5) Air fresheners whose VOC constituents, as defined in 
Secs. 59.202 and 59.203(f), consist of 100-percent fragrance.
    (6) Non-aerosol moth proofing products that are principally for the 
protection of fabric from damage by moths and other fabric pests in 
adult, juvenile, or larval forms.
    (7) Flooring seam sealers used to join or fill the seam between two 
adjoining pieces of flexible sheet flooring.



Sec. 59.202  Definitions.

    The terms used in this subpart are defined in the Clean Air Act 
(Act) or in this section as follows:
    Administrator means the Administrator of the United States 
Environmental Protection Agency (EPA) or an authorized representative.
    Aerosol cooking spray means any aerosol product designed either to 
reduce sticking on cooking and baking surfaces or to be directly applied 
on food for the purpose of reducing sticking on cooking and baking 
surfaces, or both.
    Aerosol product means a product characterized by a pressurized spray 
system that dispenses product ingredients in aerosol form by means of a 
propellant (i.e., a liquefied or compressed gas that is used in whole or 
in part, such as a co-solvent, to expel a liquid or any other material 
from the same self-pressurized container or from a separate container) 
or mechanically induced force. ``Aerosol product'' does not include pump 
sprays.
    Agricultural use means the use of any pesticide or method or device 
for the control of pests in connection with the commercial production, 
storage, or processing of any animal or plant crop. ``Agricultural use'' 
does not include the sale or use of pesticides in properly labeled 
packages or containers that are intended for:
    (1) Household use;
    (2) Use in structural pest control; or
    (3) Institutional use.
    Air freshener means any consumer product including, but not limited 
to, sprays, wicks, powders, and crystals designed for the purpose of 
masking odors, or freshening, cleaning, scenting, or deodorizing the 
air. This does not include products that are used on the human body, 
products that function primarily as cleaning products, disinfectant 
products claiming to deodorize by killing germs on surfaces, or 
institutional/industrial disinfectants when offered for sale solely 
through institutional and industrial channels of distribution. It does 
include spray disinfectants and other products that are expressly 
represented for use as air fresheners, except institutional and 
industrial disinfectants when offered for sale through institutional and 
industrial channels of distribution. To determine whether a product is 
an air freshener, all verbal and visual representations regarding 
product use on the label or packaging and in the product's literature 
and advertising may be considered. The presence of, and representations 
about, a product's fragrance and ability to deodorize (resulting from 
surface application) shall not constitute a claim of air freshening.
    All other forms means all consumer product forms for which no form-
specific VOC standard is specified. Unless specified otherwise by the 
applicable VOC standard, ``all other forms'' include, but are not 
limited to, solids,liquids, wicks, powders, crystals, and cloth or paper 
wipes (towelettes).
    Automotive windshield washer fluid means any liquid designed for use 
in a motor vehicle windshield washer system either as an antifreeze or 
for the purpose of cleaning, washing, or wetting the windshield. 
``Automotive windshield washer fluid'' does not include fluids placed by 
the manufacturer in a new vehicle.
    Bathroom and tile cleaner means a product designed to clean tile or 
surfaces in bathrooms. ``Bathroom and tile cleaner'' does not include 
products specifically designed to clean toilet bowls or toilet tanks.
    Carburetor and choke cleaner means a product designed to remove dirt 
and other contaminants from a carburetor or choke. ``Carburetor and 
choke cleaner'' does not include products designed to be introduced 
directly into the fuel lines or fuel storage tank prior to introduction 
into the carburetor, or solvent use regulated under 40 CFR part

[[Page 300]]

63, subpart T (halogenated solvent national emission standards for 
hazardous air pollutants (NESHAP)).
    Charcoal lighter material means any combustible material designed to 
be applied on, incorporated in, added to, or used with charcoal to 
enhance ignition. ``Charcoal lighter material'' does not include any of 
the following:
    (1) Electrical starters and probes;
    (2) Metallic cylinders using paper tinder;
    (3) Natural gas; and
    (4) Propane.
    Construction and panel adhesive means any one-component household 
adhesive having gap-filling capabilities that distributes stress 
uniformly throughout the bonded area resulting in a reduction or 
elimination of mechanical fasteners.
    Consumer means any person who purchases or acquires any consumer 
product for personal, family, household, or institutional use. Persons 
acquiring a consumer product for resale are not ``consumers'' of that 
product.
    Consumer product means any household or institutional product 
(including paints, coatings, and solvents), or substance, or article 
(including any container or packaging) held by any person, the use, 
consumption, storage, disposal, destruction, or decomposition of which 
may result in the release of VOC. For the purposes of this subpart, 
consumer product means any product listed in tables 1 or 2 of this 
subpart.
    Contact adhesive means any household adhesive that:
    (1) When applied to two substrates, forms an instantaneous, 
nonrepositionable bond;
    (2) When dried to touch, exhibits a minimum 30-minute bonding range; 
and
    (3) Bonds only to itself without the need for reactivation by 
solvents or heat.
    Container or packaging means the part or parts of the consumer 
product that serve only to contain, enclose, incorporate, deliver, 
dispense, wrap, or store the chemically formulated substance or mixture 
of substances that is solely responsible for accomplishing the purposes 
for which the product was designed or intended. ``Container or 
packaging'' includes any article onto or into which the principal 
display panel is incorporated, etched, printed, or attached.
    Crawling bug insecticide means any insecticide product that is 
designed for use against crawling arthropods including, but not limited 
to, ants, cockroaches, mites (but not house dust mites), silverfish, or 
spiders. ``Crawling bug insecticide'' does not include products for 
agricultural use or products designed to be used exclusively on humans 
or animals.
    Distributor means any person to whom a consumer product is sold or 
supplied for the purposes of resale or distribution in commerce.
    Double-phase aerosol air freshener means an aerosol air freshener 
with liquid contents in two or more distinct phases that requires the 
product container to be shaken before use to mix the phases, producing 
an emulsion.
    Dusting aid means a product designed to assist in removing dust and 
other soils from floors and other surfaces without leaving a wax or 
silicone-based coating. ``Dusting aid'' does not include products that 
consist entirely of compressed gases for use in electronic or other 
specialty areas.
    Engine degreaser means a cleaning product designed to remove grease, 
grime, oil, and other contaminants from the external surfaces of engines 
and other mechanical parts. ``Engine degreaser'' does not include any 
solvent used in parts washing equipment, or any solvent use regulated 
under 40 CFR part 63, subpart T (halogenated solvent NESHAP).
    Fabric protectant means a product designed to be applied to fabric 
substrates to protect the surface from soiling from dirt and other 
impurities or to reduce absorption of water into the fabric's fibers. 
``Fabric protectant'' does not include silicone-based products whose 
function is to provide water repellency, or products designed for use 
solely on fabrics that are labeled ``dry clean only.''
    Flea and tick insecticide means any insecticide product that is 
designed for use against fleas, ticks, and their larvae, or their eggs. 
``Flea and tick insecticide'' does not include products that are 
designed to be used exclusively on humans or animals or their bedding.

[[Page 301]]

    Flexible flooring material means asphalt, cork, linoleum, no-wax, 
rubber, seamless vinyl, and vinyl composite flooring.
    Floor polish or wax means a wax, polish, or any other product 
designed to polish, protect, or enhance floor surfaces by leaving a 
protective coating that is designed to be periodically replenished. 
``Floor polish or wax'' does not include ``spray buff products,'' 
products designed solely for the purpose of cleaning floors, floor 
finish strippers, products designed for unfinished wood floors, and 
coatings subject to 40 CFR part 59, subpart D--National Volatile Organic 
Compound Emission Standards for Architectural Coatings.
    Floor seam sealer means any low viscosity specialty adhesive used in 
small quantities for the sole purpose of bonding adjoining rolls of 
installed flexible sheet flooring or to fill any minute gaps between and 
adjoining rolls.
    Flying bug insecticide means any insecticide product that is 
designed for use against flying insects including, but not limited to, 
flies, mosquitoes, and gnats. ``Flying bug insecticide'' does not 
include ``wasp and hornet insecticide'' or products that are designed to 
be used exclusively on humans or animals or their bedding.
    Fragrance means a substance or mixture of aroma chemicals, natural 
essential oils, and other functional components that is added to a 
consumer product to impart an order or scent, or to counteract a 
malodor.
    Furniture maintenance product means a wax, polish, conditioner, or 
any other product designed for the product designed for the purpose of 
polishing, protecting, or enhancing finished wood surfaces other than 
floors. Furniture maintenance product'' does not include dusting aids, 
products designed solely for the purpose of cleaning, and products 
designed to leave a permanent finish such as stains, sanding sealers, 
and lacquers.
    Gel means a colloid in which the dispersed phase has combined with 
the continuous phase to produce a semisolid material, such as jelly.
    General purpose adhesive means any nonaerosol household adhesive 
designed for use on a variety of substrates. General purpose adhesives 
do not include contact adhesives or construction and panel adhesives.
    General purpose cleaner means a product designed for general all-
purpose cleaning, in contrast to cleaning products designed to clean 
specific substrates in certain situations. ``General purpose cleaner'' 
includes products designed for general floor cleaning, kitchen or 
countertop cleaning, and cleaners designed to be used on a variety of 
hard surfaces.
    Glass cleaner means a cleaning product designed primarily for 
cleaning surfaces made of glass. Glass cleaner does not include products 
designed solely for the purpose of cleaning optical materials used in 
eyeglasses, photographic equipment, scientific equipment, and 
photocopying machines.
    Hair mousse means a hairstyling foam designed to facilitate styling 
of a coiffure and provide limited holding power.
    Hair styling gel means a high-viscosity, often gelatinous product 
that contains a resin and is designed for the application to hair to aid 
in styling and sculpting of the hair coiffure.
    Hairspray means a consumer product designed primarily for the 
purpose of dispensing droplets of a resin on and into a hair coiffure to 
impart sufficient rigidity to the coiffure to establish or retain the 
style for a period of time.
    High-volatility organic compound or HVOC means any organic compound 
that exerts a vapor pressure greater than 80 millimeters of mercury when 
measured at 20 degrees Celsius.
    Household adhesive means any household product that is used to bond 
one surface to another by attachment. ``Household adhesive'' does not 
include products used on humans or animals, adhesive tape, contact 
paper, wallpaper shelf liners, or any other product with an adhesive 
incorporated onto or in an inert substrate.
    Household product means any consumer product that is primarily 
designed to be used inside or outside of living quarters or residences, 
including the immediate surroundings, that are occupied or intended for 
occupation by individuals.
    Household use means use of a product in a home or its immediate 
environment.

[[Page 302]]

    Importer means any person who brings a consumer product that was 
manufactured, filled, or packaged at a location outside of the United 
States into the United States for sale or distribution in the United 
States.
    Industrial use means use for, or in, a manufacturing, mining, or 
chemical process or use in the operation of factories, processing 
plants, and similar sites.
    Insecticide means a pesticide product that is designed for use 
against insects or other arthropods, excluding any product that is:
    (1) For agricultural use; or
    (2) A restricted use pesticide.
    Insecticide fogger means any insecticide product designed to release 
all or most of its content as a fog or mist into indoor areas during a 
single application. Foggers may target a variety of pests including (but 
not limited to) fleas and ticks, crawling insects, lawn and garden 
pests, and flying insects. Foggers are not subject to the specific VOC 
limitations or other categories of insecticides list in table 1 of this 
subpart.
    Institutional product means a consumer product that is designed for 
use in the maintenance or operation of an establishment that 
manufactures, transports, or sells goods or commodities, or provides 
services for profit; or is engaged in the nonprofit promotion of a 
particular public, educational, or charitable cause. ``Establishments'' 
include, but are not limited to, government agencies, factories, 
schools, hospitals, sanitariums, prisons, restaurants, hotels, stores, 
automobile service and parts centers, health clubs, theaters, or 
transportation companies. ``Institutional product'' does not include 
household products and products that are incorporated into or used 
exclusively in the manufacture or construction of the goods or 
commodities that are produced by the establishment.
    Institutional use means use within the confines of or on property 
necessary for the operation of buildings' including, but not limited to, 
government agencies, factories, sanitariums, prisons, restaurants, 
hotels, stores, automobile service and parts centers, health clubs, 
theaters, transportation companies, hospitals, schools, libraries, 
auditoriums, and office complexes.
    Label means any written, printed, or graphic matter affixed to, 
applied to, attached to, blown into, formed, molded into, embossed on, 
or appearing upon any consumer product package for purposes of branding, 
identifying, or giving information with respect to the product or to the 
contents of the package.
    Laundry prewash means a product that is designed for application to 
a fabric prior to laundering and that supplements and contributes to the 
effectiveness of laundry detergents and/or provides specialized 
performance.
    Laundry starch product means a product that is designed for 
application to a fabric, either during or after laundering, to impart 
and prolong a crisp look and may also facilitate ironing of the fabric. 
``Laundry starch product'' includes, but it not limited to, fabric 
finish, sizing, and starch.
    Lawn and garden insecticide means an insecticide product designed 
primarily to be used in household lawn and garden areas to protect 
plants from insects or other arthropods.
    Liquid means a substance or mixture of substances that flows 
readily, but, unlike a gas, does not expand indefinitely (i.e., a 
substance with constant volume but not constant shape). ``Liquid'' does 
not include powders or other materials that are composed entirely of 
solid particles.
    Manufacturer means any person who manufacturers or processes a 
consumer product. Manufacturers include:
    (1) Processors who blend and mix consumer products,
    (2) Contract fillers who develop formulas and package these formulas 
under a distributor's label;
    (3) Contract fillers who manufacture products using formulas 
provided by a distributor; and
    (4) Distributors who specify formulas to be used by a contract 
filler or processor.
    Nail polish remover means a product designed to remove nail polish 
or coatings from fingernails or toenails.
    Nonagricultural pesticide means and includes any substance or 
mixture of

[[Page 303]]

substances that is a pesticide as defined in section 2(u) of the Federal 
Insecticide, Fungicide, and Rodenticide Act (7 U.S.C. 136-136y).
    Nonresilient flooring means floor of a mineral content that is not 
flexible. ``Nonresilient flooring'' includes, but is not limited to, 
terrazzo, marble, slate, granite, brick, stone, ceramic tile, and 
concrete.
    Oven cleaner means any cleaning product designed to clean and to 
remove dried food deposits from oven interiors.
    Person means an individual corporation, partnership, association, 
State, any agency, department, or instrumentality of the United States, 
and any officer, agent, or employee thereof.
    Principal display panel(s) means that part, or those parts, of a 
label that are so designed as to most likely be displayed, presented, 
shown, or examined under normal and customary conditions of display or 
purchase. Whenever a principal display panel appears more than once, all 
requirements pertaining to the ``principal display panel'' shall pertain 
to all such ``principal display panels.''
    Product category means that applicable category which best describes 
the product as listed in tables 1 or 2 of this subpart and which appears 
on the product's principal display panel.
    Product form means the form that most accurately describes the 
product's dispensing from including aerosols, gels, liquids, pump 
sprays, and solids.
    Pump spray means a packaging system in which the product ingredients 
are expelled only while a pumping action is applied to a button, 
trigger, or other actuator. Pump spray product ingredients are not under 
pressure.
    Representative consumer product means a consumer product that is 
subject to the same VOC limit in Sec. 59.203 as the innovative product.
    Restricted use pesticide means a pesticide that has been classified 
for restricted use under the provisions of section 3(d) of the Federal 
Insecticide, Fungicide, and Rodenticide Act (7 U.S.C. 136-136y).
    Shaving cream means an aerosol product that dispenses a foam lather 
intended to be used with a blade or cartridge razor, or other wet-
shaving system in the removal of facial or other body hair.
    Single-phase aerosol air freshener means an aerosol air freshener 
with liquid contents in a single homogeneous phase that does not require 
that the product container be shaken before use.
    Solid means a substance or mixture of substances that does not flow 
or expand readily (i.e., a substance with constant volume such as the 
particles constituting a powder). ``Solid'' does not include liquids or 
gels.
    Spray buff product means a product designed to restore a worn floor 
finish in conjunction with a floor buffing machine and special pad.
    Structural waterproof adhesive means an adhesive whose bond lines 
are resistant to conditions of continuous immersion in fresh or salt 
water, and that conforms with Federal Specification MMM-A-181 (Type 1, 
Grade A), and MIL-A-4605 (Type A, Grade A and Grade C).
    Underarm antiperspirant means any aerosol product that is intended 
by the manufacturer to be used to reduce perspiration in the human 
axilla by at least 20 percent in at least 50 percent of a target 
population.
    Underarm deodorant means any aerosol product that is intended by the 
manufacturer to be used minimize odor in the human axilla by retarding 
the growth of bacteria that cause the decomposition of perspiration.
    United States means the United States of America, including the 
District of Columbia, the Commonwealth of Puerto Rico, the Virgin 
Islands, Guam, American Samoa, and the Commonwealth of the Northern 
Mariana Islands.
    Usage directions means the text or graphics on the consumer 
product's label or accompanying literature that describes to the end 
user how and in what quantity the product is to be used.
    Volatile organic compound or VOC means any compound that meets the 
definition of a VOC, as defined under 40 CFR part 51, subpart F, and in 
subsequent amendments.
    Wasp and hornet insecticide means any insecticide product that is 
designed for

[[Page 304]]

use against wasps, hornets, yellow jackets, or bees by allowing the user 
to spray a high-volume directed stream or burst from a safe distance at 
the intended pest or its hiding place.
    Wax means an organic mixture or compound with low melting point and 
high molecular weight, which is solid at room temperature. Waxes are 
generally similar in composition to fats and oils except that they 
contain no glycerides. ``Wax'' includes, but is not limited to, 
substances such as carnauba wax, lanolin, and beeswax derived from the 
secretions of plants and animals; substances of a mineral origin such as 
ozocerite, montan, and paraffin; and synthetic substances such as 
chlorinated naphthalenes and ethylenic polymers.
    Wood floor wax means wax-based products for use solely on wood 
floors.

[63 FR 48815, Sept. 11, 1998; 63 FR 52319, Sept. 30, 1998]



Sec. 59.203  Standards for consumer products.

    (a) The manufacturer or importer of any consumer product subject to 
this subpart small ensure that the VOC content levels in table 1 of this 
subpart and HVOC content levels in table 2 of this subpart are not 
exceeded for any consumer product manufactured or imported on or after 
December 10, 1998, except as provided in paragraphs (b) and (c) of this 
section, or in Secs. 59.204 or 59.206.
    (b) For consumer products for which the label, packaging, or 
accompanying literature specifically states that the product should be 
diluted prior to use, the VOC content limits specified in paragraph (a) 
of this section shall apply to the product only after the minimum 
recommended dilution has taken place. For purposes of this paragraph, 
``minimum recommended dilution'' shall not include recommendations for 
incidental use of a concentrated product to deal with limited special 
applications such as hard-to-remove soils or stains.
    (c) For those consumer products that are registered under the 
Federal Insecticide, Fungicide, and Rodenticide Act (7 U.S.C. section 
136-136y) (FIFRA), the compliance date of the VOC standards specified in 
paragraph (a) of this section is December 10, 1999.
    (d) The provisions specified in paragraphs (d)(1) through (d)(4) of 
this section apply to charcoal lighter materials.
    (1) No person shall manufacture or import any charcoal lighter 
material after December 10, 1998 that emits, on average, greater than 9 
grams of VOC per start, as determined by the procedures specified in 
Sec. 59.208.
    (2) The regulated entity for a charcoal lighter material shall label 
the product with usage directions that specify the quantity of charcoal 
lighter material per pound of charcoal that was used in the testing 
protocol specified in Sec. 59.208 for that product unless the provisions 
in either paragraph (e)(2)(i) or (e)(2)(ii) of this section apply.
    (i) The charcoal lighter material is intended to be used in fixed 
amounts independent of the amount of charcoal used, such as paraffin 
cubes; or
    (ii) The charcoal lighter material is already incorporated into the 
charcoal, such as certain ``bag light,'' ``instant light,'' or ``match 
light'' products.
    (3) Records of emission testing results for all charcoal lighter 
materials must be made available upon request to the Administrator for 
enforcement purposes within 30 days of receipt of such requests.
    (4) If a manufacturer or importer has submitted records of emission 
testing of a charcoal lighter material to a State or local regulatory 
agency, such existing records may be submitted under paragraph (d)(3) of 
this section in lieu of new test data, provided the product formulation 
is unchanged from that which was previously tested. Such previous 
testing must have been conducted in accordance with the test protocol 
described in Sec. 59.208 or a test protocol that is approved by the 
Administrator as an alternate.
    (e) Fragrances incorporated into a consumer product up to a combined 
level of 2 weight-percent shall not be included in the weight-percent 
VOC calculation.
    (f) The VOC content limits in table 1 of this subpart shall not 
include any VOC that:

[[Page 305]]

    (1) Has a vapor pressure of less than 0.1 millimeters of mercury at 
20 degrees Celsius; or
    (2) Consists of more than 12 carbon atoms, if the vapor pressure is 
unknown; or
    (3) Has a melting point higher than 20 degrees Celsius and does not 
sublime (i.e., does not change directly from a solid into a gas without 
melting), if the vapor pressure is unknown.
    (g) The requirements of paragraph (a) of this Section shall not 
apply to those VOC in antiperspirants or deodorants that contain more 
than 10 carbon atoms per molecule and for which the vapor pressure is 
unknown, or that have a vapor pressure of 2 millimeters of mercury or 
less at 20 degrees Celsius.
    (h) a manufacturer or importer may use the vapor pressure 
information provided by the raw material supplier as long as the 
supplier uses a method to determine vapor pressure that is generally 
accepted by the scientific community.
    (i) For hydrocarbon solvents that are complex mixtures of many 
different compounds and that are supplied on a specification basis for 
use in a consumer product, the vapor pressure of the hydrocarbon blend 
may be used to demonstrate compliance with the VOC content limits of 
this section. Identification of the concentration and vapor pressure for 
each such component in the blend is not required for compliance with 
this subpart.



Sec. 59.204   Innovative product provisions.

    (a) Upon notification to the Administrator, a consumer product that 
is subject to this subpart may exceed the applicable limit in table 1 or 
2 of this subpart if the regulated entity demonstrates that, due to some 
characteristic of the product formulation, design, delivery systems, or 
other factors, the use of the product will result in equal or less VOC 
emissions that specified in paragraph (a)(1) or (a)(2) of this section.
    (1) The VOC emissions from a representative consumer product, as 
described in Sec. 59.202, that complies with the VOC standards specified 
in Sec. 59.203(a); or
    (2) The calculated VOC emissions from a noncomplying representative 
product, if the product had been reformulated to comply with the VOC 
standards specified in Sec. 59.203(a). The VOC emissions shall be 
calculated by using Equation 1.
[GRAPHIC] [TIFF OMITTED] TR11SE98.002

Where
ER=The VOC emissions from the noncomplying representative 
product, had it been reformulated.
ENC=The VOC emissions from the noncomplying representative 
product in its current formulation.
VOCSTD=The VOC standard specified in Sec. 59.203(a).
VOCNC=The VOC content of the noncomplying product in its 
current formulation.

    (b) If a regulated entity demonstrates to the satisfaction of the 
Administrator that the equation in paragraph (a)(2) of the this section 
yields inaccurate results due to some characteristic of the product 
formulation or other factors, an alternate method that accurately 
calculates emissions may be used upon approval of the Administrator.
    (c) A regulated entity shall notify the Administrator in writing of 
its intent to enter into the market an innovative product meeting the 
requirements of paragraph (a) of this section. The Administrator must 
receive the written notification by the time the innovative product is 
available for sale or distribution to consumers. Notification shall 
include the information specified in paragraph (c)(1) and (c)(2) of this 
section.
    (1) Supporting documentation that demonstrates the emissions from 
the innovate product, including the actual physical test methods used to 
generate the data and, if necessary, the consumer testing undertaken to 
document product usage;
    (2) Any information necessary to enable the Administrator to 
establish enforceable conditions for the innovative product, including 
the VOC content of the innovative product expressed as a weight-
percentage, and test methods for determining the VOC content.
    (d) At the option of the regulated entity, the regulated entity may 
submit

[[Page 306]]

a written request for the Administrator's written concurrence that the 
innovative product fulfills the requirements of paragraph (a) of this 
section. If such a request is made, the Administrator will respond as 
specified in paragraphs (d)(1) through (d)(3) of this section.
    (1) The Administrator will determine within 30 days of receipt 
whether the documentation submitted in accordance with paragraph (d) of 
this section is complete.
    (2) The Administrator will determine whether the innovative product 
shall be exempt from the requirements of Sec. 59.203(a) within 90 days 
after an application has been deemed complete. The applicant and the 
Administrator may mutually agree to a longer time period for reaching a 
decision, and additional supporting documentation may be submitted by 
the applicant before a decision has been reached. The Administrator will 
notify the applicant of the decision in writing and specify such terms 
and conditions that are necessary to insure that emissions from the 
product will meet the emissions reductions specified in paragraph (a) of 
this section, and that such emissions reductions can be enforced.
    (3) If an applicant has been granted an exemption to a State or 
local regulation for an innovative product by a State or local agency 
whose criteria for exemption meet or exceed those provided for in this 
section, the applicant may submit the factual basis for such an 
exemption as part of the documentation required under paragraph (d) of 
this section. In such case, the Administrator will make the 
determination required under this paragraph within 45 days after the 
applications is considered complete.
    (e) In granting an exemption for a product, the Administrator will 
establish conditions that are enforceable. These conditions may include 
the VOC content of the innovative product, dispensing rates, application 
rates, and any other parameters determined by the Administrator to be 
necessary. The Administrator will also specify the test methods for 
determining conformance to the conditions established, including 
criteria for reproducibility, accuracy, and sampling and laboratory 
procedures.
    (f) For any product for which an exemption has been granted pursuant 
to this section, the regulated entity to whom the exemption was granted 
shall notify the Administrator in writing within 30 days after any 
change in the product formulation or recommended product usage 
directions, and shall also notify the Administrator within 30 days after 
the regulated entity learns of any information that would alter the 
emissions estimates submitted to the Administrator in support of the 
exemption application.
    (g) If lower VOC content limits are promulgated for a product 
category through any subsequent rulemaking, all exemptions granted under 
this section for products in the product category shall no longer apply 
unless the innovative product has been demonstrated to have VOC 
emissions less than the applicable revised VOC content limits.
    (h) If the Administrator determines that a consumer product for 
which an exemption has been granted no longer meets the VOC emissions 
criteria specified in paragraph (a) of this section for an innovative 
product, the Administrator may modify or revoke the exemption as 
necessary to assure that the product will meet these criteria. The 
Administrator will not modify or revoke an exemption without first 
affording the applicant an opportunity for a public hearing to determine 
if the exemption should be modified or revoked.

[63 FR 48815, Sept. 11, 1998; 63 FR 52319, Sept. 30, 1998]



Sec. 59.205  Labeling.

    (a) The container or package of each consumer product that is 
subject to this subpart shall clearly display the day, month, and year 
on which the product was manufactured, or a code indicating such date. 
The requirements of this provision shall not apply to products that are 
offered to consumers free of charge for the purposes of sampling the 
product.
    (b) In addition, the container or package for each charcoal lighter 
material that is subject to this subpart

[[Page 307]]

shall be labeled according to the provisions of Sec. 59.203(d)(2).



Sec. 59.206   Variances.

    (a) Any regulated entity who cannot comply with the requirements of 
this subpart because of extraordinary circumstances beyond reasonable 
control may apply in writing to the Administrator for a variance. The 
variance application shall include the information specified in 
paragraph (a)(1) through (a)(3) of this section.
    (1) The specific grounds up on which the variance is sought,
    (2) The proposed date(s) by which compliance with the provisions of 
this subpart will be achieved. Such date(s) shall be no later than 5 
years after the issuance of a variance; and
    (3) A compliance plan detailing the method(s) by which compliance 
will be achieved.
    (b) Upon receipt of a variance application containing the 
information required in paragraph (a) of this section, the Administrator 
will publish a notice of such application in the Federal Register and, 
if requested by any party, will hold a public hearing to determine 
whether, under what conditions, and to what extent, a variance from the 
requirements of this subpart is necessary and will be granted. If 
requested, a hearing will be held no later than 75 days after receipt of 
a variance application. Notice of the time and place of the hearing will 
be sent to the applicant by certified mail not less than 30 days prior 
to the hearing. At least 30 days prior to the hearing, the variance 
application will be made available to the public for inspection. 
Information submitted to the Administrator by a variance applicant may 
be claimed as confidential. The Administrator may consider such 
confidential information in reaching a decision on a variance 
application. Interested members of the public will be allowed a 
reasonable opportunity to testify at the hearing.
    (c) The Administrator will grant a variance if the criteria 
specified in paragraphs (c)(1) and (c)(2) of this section are met.
    (1) If there are circumstances beyond the reasonable control of the 
applicant so that complying with the provisions of this subpart by the 
compliance date would not be technologically or economically feasible, 
and
    (2) The compliance plan proposed by the applicant can be implemented 
and will achieve compliance as expeditiously as possible.
    (d) Any variance order will specify a final compliance date by which 
the requirements of this subpart will be achieved and increments of 
progress necessary to assure timely compliance.
    (e) A variance shall cease to be effective upon failure of the 
regulated entity to comply with any term or condition of the variance.
    (f) Upon the application of any party, the Administrator may review, 
and for good cause, modify or revoke a variance after holding a public 
hearing in accordance with the procedures described in paragraph (b) of 
this section.



Sec. 59.207  Test methods.

    Each manufacturer or importer subject to the provisions of 
Sec. 59.203(a) shall demonstrate compliance with the requirements of 
this subpart through calculation of the VOC content using records of the 
amounts of constituents used to manufacture the product.



Sec. 59.208  Charcoal lighter material testing protocol.

    (a) Each manufacturer or importer of charcoal lighter material 
subject to this subpart shall demonstrate compliance with the applicable 
requirements of Sec. 59.203(d) using the procedures specified in this 
section. Any lighter material that has received certification from 
California South Coast Air Quality Management District (SCAQMD) under 
their Rule 1174, Ignition Method Compliance Certification Testing 
Protocol, will be considered as having demonstrated compliance with the 
applicable requirements of this subpart using the procedures in this 
section.
    (b) The manufacturer or importer shall obtain from the testing 
laboratory conducting the testing, a report of findings, including all 
raw data sheets/charts and laboratory analytical data. The testing must 
demonstrate that VOC emissions resulting from the ignition of the 
barbecue charcoal are, on average, less than or equal to 9 grams

[[Page 308]]

per start. The manufacturer or importer shall maintain the report of 
findings.
    (c) When a charcoal lighter material does not fall within the 
testing guidelines of this protocol, the protocol may be modified 
following a determination by the Administrator that the modified 
protocol is an acceptable alternative to the method described in this 
section and written approval of the Administrator.
    (d) Meteorological and environmental criteria. (1) Testing shall be 
conducted under the following conditions:
    (i) Inlet combustion air temperature is 16 to 27 degrees Celsius (60 
to 80 degrees Fahrenheit) with a relative humidity of 20 to 80 percent;
    (ii) The charcoal and lighter material are stored 72 hours before 
testing in a location with a relative humidity between 45 and 65 
percent, and a temperature between 18 and 24 degrees Celsuis (65 to 75 
degrees Fahrenheit); and
    (iii) The outside wind speed, including gusts, may be no more than 
16 kilometers per hour (10 miles per hour) if the test stack is 
exhausted outdoors, or, if the test stack is exhausted indoors, indoor 
air must be stagnant.
    (2) Temperature and relative humidity of the combustion air shall be 
continuously monitored during the test. Temperature and relative 
humidity of the place where the charcoal and lighter material are stored 
prior to the test shall be monitored and recorded during the 72 hours 
immediately prior to the test. If the stack is exhausted outdoors, the 
continuous outdoor wind speed monitor shall be observed or recorded 
continuously during testing. If the wind speed monitor is manually 
observed rather than electronically recorded, the maximum wind speed 
observed during the test shall be recorded.
    (e) Definitions. For the purposes of this test protocol, the 
following definitions shall apply:
    (1) Baseline VOC emissions (Eb) means the 3.6 grams 
(0.008 pounds) per start of subject VOC mass emissions (calculated as 
CH2) resulting from the ignition of charcoal by electric 
probe.
    (2) Emission limit for VOC means 9 grams per start of resultant VOC 
emissions (Er), (expressed as CH2).
    (3) Equivalent means equipment that has been demonstrated to meet or 
exceed the performance, design, and operation specifications of the 
prescribed equipment. A demonstration that equipment or a test method is 
a suitable alternative requires written approval from the Administrator 
prior to compliance testing, based on an evaluation of comparative 
performance specifications and/or actual performance test data.
    (4) Ignition means the ready-to-cook condition of the charcoal 
determined by the temperature above the charcoal, the organic vapor 
concentration measured by the continuous organic emission monitor, and 
percent ash.
    (5) Ignition VOC emissions (eI)--means the grams (pounds) 
per start of total subject VOC mass emissions (expressed as 
CH2) resulting from the ignition of charcoal by the lighter 
material undergoing evaluation, including both charcoal and lighter 
material emissions.
    (6) labeled directions means those directions affixed to the 
charcoal lighter material which specify:
    (1) The amount of lighter material to use per kilogram (or pound) of 
charcoal, unless the lighter material is already impregnated or treated 
in the charcoal;
    (2) How to use or apply the lighter material; and
    (3) How and when to light the lighter material.
    (7) Percent ash means a qualitative observation of the ratio of 
visible charcoal surface area ignited (grayish/white ash) to total 
charcoal surface area times 100.
    (8) Reference VOC emissions (Eep)--means the grams 
(pounds) per start of subject VOC mass emissions (calculated as 
CH2) resulting from the ignition of charcoal by the reference 
electric probe during the testing.
    (9) Resultant VOC emissions (Er)--means the ignition VOC 
emission (EI) less the reference VOC emissions 
(Eep) plus baseline emissions (Eb).
    (10 Start means a 25-minute period commencing from the instant that 
emissions may be released from the lighter material, either by 
evaporation or combustion, and further characterized such that by the 
end of said 25-minute period, ignition is achieved.

[[Page 309]]

    (f) Test structure, equipment specifications, and reference 
materials. (1) The test structure is to be located in a building or 
fabricated total enclosure (i.e., with enclosed sides and top). The 
enclosure shall be such that there are no constant or intermittent air 
flows within it that cause fluctuations in the stack velocity and/or 
disruptions of air flow patterns within the test chamber containing the 
reference grill . (WARNING: If the stack is vented into the building 
enclosure, caution must be taken to avoid carbon monoxide poisoning and 
the reduction of oxygen.)
    (2) Test structure components. The following test structure 
components, as shown in figures 1 and 2 of Appendix A of this subpart, 
shall be used:
    (i) Test chamber--Standard large, prefabricated fireplace 
manufactured by Marco[Delta],\1\ Model No. C41CF, with flue 
damper removed; or a fabricated structure with the same dimensions. 
Spacers are required at the rear of the test chamber to ensure a 
constant 5-centimeter (2-inch) distance between the reference grill and 
the rear wall of the test chamber.
---------------------------------------------------------------------------

    \1\Note: Mention of trade names or specific products does not 
constitute endorsement by the EPA.
---------------------------------------------------------------------------

    (ii) Test stack--25-centimeter (10-inch) diameter galvanized steel 
ducting with velocity traverse port holes located approximately 8 
diameters downstream from the stack outlet of the fireplace chamber and 
sampling ports located approximately 2\1/2\ diameters downstream of the 
velocity traverse ports.
    (iii) Fan--25-centimeter (10-inch) diameter axial fan (duct fan) 
capable of maintaining an air velocity of 140  9 meters per 
minute (450  30 feet per minute) and located in the stack 
approximately 3 diameters downstream of the sampling ports.
    (iv) Test stack insulation--The stack shall be insulated with 
fiberglass blanket insulation (or equivalent) with a minimum R-value of 
6.4, that totally surrounds the stack from the top of the fireplace to 
the level of the blower which minimizes temperature gradients in the 
stack and prevents hydrocarbons from condensing on the stack wall.
    (v) Stack mounts--Supports for fixing in position the stack velocity 
measurement device for measuring reference point velocity readings and 
the continuous organic emission monitor probe/meter.
    (vi) Blower speed control--A rheostat for controlling voltage to the 
fan.
    (3) Test equipment and materials. The following test equipment and 
materials shall be used:
    (i) Continuous recording device--A YEW[Delta] model 4088 
dot matrix, roster scanning chart recorder, Omega strip recorder with a 
Strawberry Tree Data Acquisition System, or equivalent, shall be used to 
continuously (6-second cycle) record temperatures, velocity, and 
continuous organic emission monitor output signals. The recording may be 
done manually, recording temperature using a digital potentiometer (20-
second intervals), reference point velocity with a Pitot tube (20-second 
intervals), and continuous organic emission monitor readings with the 
analyzer's meter (10-second intervals).
    (ii) Grill temperature probe--A type ``K'' thermocouple silver 
soldered to a 7.6 centimeter (3-inch) square brass plate 0.083-
centimeter (0.033 inches) thick painted flat black using high 
temperature ( 370 degrees Celsius [ 700 degrees 
Fahrenheit]) paint; set on an adjustable stand to maintain 11 
centimeters (4.5 inches) above the maximum height of the briquette pile 
and made such that it can be removed and replaced within the chamber.
    (iii) Stack temperature probe--The Kurz[Delta] digital air velocity 
meter or a type ``K'' thermocouple shall be used.
    (iv) Stack velocity measurement device--The velocity in meters 
(feet) per minute for the reference point using a Kurz[Delta] digital 
air velocity meter, Davis[Delta] DTA 4000 vane anemometer, or equivalent 
to method 1A of 40 CFR part 60, appendix A.
    (v) Continuous organic emissions monitor--Century[Delta] Model 128 
Organic Vapor Analyzer, Ratfisch[Delta] RS55 total hydrocarbon analyzer, 
or equivalent, with response in parts per million (ranges 0 to 10 parts 
per million, 0 to 100 parts per million, 0 to 1,000 parts per million).

[[Page 310]]

    (vi) Temperature and humidity monitor--A chart recorder type with 
humidity accuracy of  3 percent from 15 to 85 percent.
    (vii) Wind speed and direction monitor--A wind speed and direction 
device meeting a tolerance of  10 percent.
    (viii) Analytical balance--An electronic scale with a resolution of 
a  2 grams.
    (ix) Charcoal stacking ring--Rigid metal cylinder 21.6 centimeters 
(8.5 inches) in diameter with indicators to determine that the pile of 
briquettes does not exceed 12.7 centimeters (5 inches) in height.
    (x) Camera--To document ignition condition of charcoal at the end of 
each start.
    (xi) Particulate filter--Nupro[Delta] inline filter, Catalog Number 
SS-4FW-2 with 0.64 centimeter (\1/4\-inch) Swagelok inlet and outlet or 
equivalent.
    (xii) Barbecue Grill--The charcoal shall be ignited in a 
Weber[Delta] ``Go Anywhere'' barbecue grill (Model Number 
121001), 39.4 centimeters x 24 centimeters x 12.7 centimeters 
(15.5 inch x 9.5 inch x 5.0 inch) with the grate 4.4 centimeters (1.75 
inches) above the bottom of the grill, or another grill that meets these 
specifications. The grill shall be set on its bottom when placed in the 
test chamber and all grill air vents shall be in full open position.
    (xiii) Electric probe--A 600-watt electric probe shall be used for 
electric probe ignition tests.
    (xiv) Untreated charcoal--The laboratory conducting the testing 
shall purchase ``off the shelf'' untreated charcoal from a retail 
outlet. Charcoal shall not be provided by the manufacturer of the 
charcoal lighter material to be tested or by the charcoal manufacturer. 
The charcoal to be used is Kingsford[Delta] ``Original Charcoal 
Briquets.'' All untreated charcoal used in the certification testing of 
a single ignition source is to come from the same lot as indicated by 
the number printed on the bag.
    (xv) Treated or impregnated charcoal--If the charcoal lighter 
material to be tested is a substance used to treat or impregnate 
charcoal, the regulated entity shall provide to the laboratory 
conducting the tests a sample of impregnated charcoal. The sample shall 
be impregnated or treated barbecue charcoal that is ignited either 
outside of package or ignited by the package. If commercially available, 
the independent testing laboratory conducting the test shall purchase 
``off the shelf'' from a retail outlet.
    (g) Sampling and analytical methods. (1) Gas volumetric flow rate. 
Conduct a full velocity traverse using the stack velocity measurement 
device as shown in figure 3 of this Appendix A to this Subpart, or use 
Method 1A of 40 CFR part 60, appendix A. Continuously record a velocity 
reference point reading during each test run using a chart recorder or 
once every 20 seconds if using Method 1A. Calculate the volumetric flow 
rate using the gas velocity, moisture content, and the stack cross-
sectional area. For the purposes of this protocol, the static pressure 
shall be assumed to be atmospheric, the molar density correction factor 
in the stack to be 1.0, and the moisture content to be 2 percent.
    (2) Integrated VOC sample. Collect integrated VOC gas samples at the 
sampling port in the exhaust stack using a 40 CFR part 60, appendix A, 
Method 25 Total Combustion Analysis (TCA) sampling apparatus consisting 
of two evacuated 9-liter tanks, each equipped with flow controllers, 
vacuum gauges, and probes, as shown in figure 4 of Appendix A of this 
Subpart. Use 40 CFR part 60, appendix A, Method 25, SCAQMD Method 25.1 
(incorporated by reference--Sec. 59.213 of this subpart), or equivalent, 
for analysis. Carbon monoxide, carbon dioxide, methane, and non-methane 
organic carbon are analyzed by the TCA and TCA/Flame Ionization Detector 
(FID) methods. Oxygen content is determined by gas chromatography using 
a thermal conductivity detector. Clean particulate filters between use 
by heating to 760 degrees Celsius (1400 degrees Fahrenheit) while using 
compressed air as a carrier for cleaning and purging.
    (3) Continuous organic emissions monitor. A continuous organic 
emissions monitor which uses a continuous FID shall be used for each 
test run to measure the real time organic concentration of the exhaust 
as methane. Record the emission monitor response

[[Page 311]]

in parts per million continuously during the sampling period using a 
chart recorder or at least once every 10 seconds. The VOC analyzer shall 
be operated as prescribed in the manufacturer's directions unless 
otherwise noted in this protocol.
    (h) Pretest procedure. (1) Charcoal lighter material--charcoal. 
Before each test run, remove charcoal from a sealed bag that has been 
stored for at least 72 hours in a humidity and temperature controlled 
room which satisfies the requirements of paragraph (d)(1) of this 
section and weight out 0.9 kilograms (2 pounds) of charcoal briquettes, 
to the nearest whole briquette over 0.9 kilograms (2 pounds), of uniform 
shape with no broken pieces using an analytical balance. Reseal the bag. 
Charcoal must be ignited within 10 minutes after removal from bag. A 
sealed or resealed bag of charcoal cannot be stored at the test site for 
greater than 45 minutes. It must be returned to a humidity and 
temperature controlled room from 72 hours. The lighter material must be 
purchased, stored, weighed, and handled the same as the barbecue 
charcoal.
    (i) For the reference VOC emission tests using an electric probe, 
place a single layer of charcoal, slightly larger than the area/circle 
of the electric probe heating element, onto the grate. Place the heating 
element on top of this first layer and cover the heating element with 
the remaining charcoal briquettes.
    (ii) For the ignition VOC emissions tests, arrange the briquettes on 
the barbecue grate in the manner specified by the ignition 
manufacturer's directions. If these manufacturer's directions do not 
specify a stacking arrangement for the briquettes, randomly stack the 
briquettes in a pile using the stacking ring described in paragraph 
(f)(3)(ix) of this section.
    (2) Charcoal lighter material--or impregnated charcoal. Store, 
handle, weigh, and stack barbecue charcoal that is designed to be lit 
without the packaging, the same as in paragraph (h)(1) of this section. 
For those products which require both the package and charcoal be lit, 
weigh the whole package--do not remove charcoal. Weigh an empty package 
(not the same one to be used during the test). Subtract the package 
weight from the overall weight of the package and charcoal. The full 
package and empty package must be stored, handled, and weighed the same 
as in paragraph (h)(1) of this section. If the difference (the charcoal 
weight) is between 0.7 to 1.4 kilograms (1.5 to 3.0 pounds), the test 
may proceed. The emissions measured (E) in Equation 5 of paragraph 
(k)(7) of this section must be adjusted to a 0.9 kilogram (2-pound) 
charge. Place packaged barbecue charcoal on the grate in the manner 
specified by the manufacturer's directions.
    (3) Initial meteorological and environmental criteria in paragraph 
(d) shall be complied with.
    (4) The stack velocity must be set before each day of testing at 140 
 9 meters per minute (450  30 feet per minute) 
by performing a velocity traverse as specified in paragraph (g)(1) of 
this section. The velocity will be attained by adjusting the axial fan 
speed using a rheostat.
    (5) The fireplace shall be conditioned at the start of each day 
before sampling tests by using a grill ignited by the electric probe. If 
a time period of over 60 minutes between sampling test runs occur, the 
condition step must be repeated.
    (6) Before each test run, leak check the continuous organic 
emissions monitor by blocking the flow to the probe. Allow the 
instrument to warm up for the duration specified by the manufacturer's 
directions. Select the 0 to 100 parts per million range. Check the 
battery level and hydrogen pressure. Zero with hydrocarbon-free air 
(<0.1 parts per million hydrocarbons as methane) span with 90 parts per 
million methane in ultra pure air. Zero and span another instrument 
selection range if needed for test purposes.
    (7) Before the testing program begins, establish a point of average 
concentration of organics in the stack by using a continuous organic 
emissions monitor and a grill with charcoal ignited by the electric 
probe 40 minutes after initial release of emissions. Record the 
continuous organic emissions monitor traverse data.
    (8) Prepare the integrated VOC sampling equipment and perform the 
required leak checks. Fit the probes with

[[Page 312]]

nozzles housing two micron particulate filters. Insert the probes and 
nozzles into the sampling port to draw a sample of the exhaust gas from 
the point of average organic concentration as determined from the 
continuous organic emissions monitor sample traverse described in 
paragraph (h)(4) of this section. Also, position the nozzles such that 
they point downstream in the stack. Obtain the samples concurrently and 
continuously over the test run.
    (9) Insert the continuous organic emissions monitor probe into the 
sampling port to draw a sample of the exhaust gas from the point of 
average organic concentration as determined from the continuous organic 
emissions monitor sample traverse described in paragraph (h)(7) of this 
section.
    (i) Test procedure. The labeled directions, as defined in paragraph 
(e) of this section, shall be followed throughout the course of the 
testing. In cases where the directions are incompatible with this 
protocol, circumvent the intent of this protocol, or are unclear 
(subject to different interpretations) and inadequate, the Administrator 
must be informed in writing of the nature of the conflict, as well as 
the proposed resolution, prior to commencing testing. When the labeled 
directions for a charcoal lighter material do not fall within the 
testing guidelines of this protocol, the protocol may only be modified 
upon written approval of the Administrator.
    (1) Place the bottom of the barbecue grill on the floor of the 
fireplace, 5 centimeters (2 inches) from the rear wall. Ignite charcoal 
as specified by manufacturer's labeled directions.
    (2) For electric probe ignition, carefully remove probe without 
disturbing charcoal after 10 minutes of operation.
    (3) For fluid ignition, simultaneously match light fluid on charcoal 
and fluid that has fallen to the bottom of the grill.
    (4) Place the grill temperature probe 11 centimeters (4.5 inches) 
above the top of the charcoal immediately after the charcoal lighter 
material flame goes out, or before, if the lighter material does not 
flame.
    (5) Conduct at least six test runs for both the electric probe 
ignition and for the lighter material being evaluated. Alternate these 
lighter material for all 12 runs. All runs must be conducted over 3 
consecutive days or less. Alternatively, baseline emissions testing 
(using the electric probe) may be applied to other test runs provided 
the test runs occur within 4 months of the baseline testing. Integrated 
VOC sampling and continuous organic emissions monitoring begin for each 
test run when the charcoal lighter material and/or materials start to 
generate/release organics (this will be the time of pouring for lighter 
fluids and the time of ignition for most other ignition sources). 
Option: Because the manufacturer of treated or impregnated charcoal 
supplies both the lighter material and barbecue charcoal, they may apply 
the 9 grams VOC per start emission limit as an absolute value without an 
adjustment for the VOC emissions from an electric probe.
    (6) Sampling ends for each test run when all the following 
conditions are met:
    (i) The temperature 11 centimeters (4.5 inches) above the maximum 
height of the briquette pile, using the grill temperature probe 
described in paragraph (d)(3)(ii) of this section, is at least 93 
degrees Celsius (200 degrees Fahrenheit);
    (ii) The continuous organic emissions monitor is reading below 30 
parts per million for at least 2 minutes;
    (iii) The test sampling has continued for 25 minutes (but not more) 
and
    (iv) The charcoal surface is 70 percent covered with ash (to be 
documented with photograph on top and 60 degrees above the horizon).
    (7) During the sampling test runs, temperatures (excluding ambient) 
and continuous organic emission monitor readings shall be recorded and 
shall comply with the requirements in paragraph (b) of this section. 
Humidity, wind speed, and ambient temperature readings shall be 
monitored and shall comply with the requirements in paragraph (b) of 
this section.
    (8) Collect one blank sample for VOC and one ambient air sample 
during one run of each day per paragraph (k) of this section.

[[Page 313]]

    (j) Post-run procedure. (1) Record temperatures (including ambient), 
humidity, wind speed, and continuous organic emissions monitor reading.
    (2) Record the drift using zero and span gases. Leak check and span 
the continuous organic emissions monitor as described in paragraph 
(h)(6) of this section for the next run.
    (3) Leak check and disassemble the integrated VOC sampling equipment 
as described in Method 25 of 40 CFR part 60, appendix A or SCAQMD Method 
25.1 (incorporated by reference--see Sec. 59.213 of this subpart), or 
equivalent.
    (4) Thoroughly clean grill surfaces of all residue before conducting 
next ignition run.
    (k) Calculations. Calculations shall be carried out to at least one 
significant digit beyond that of the acquired data, and then rounded off 
after final calculation to two significant digits for each run. All 
rounding off of numbers should be in accordance with the American 
Society for Testing and Materials (ASTM) E 380-93, Standard Practice for 
Use of the SI International System of Units, procedures (incorporated by 
reference--see Sec. 59.213 of this subpart).
    (1) Calculate the average stack reference point temperature during 
sampling (tsr).
    (2) Calculate the average measured velocities (in meters per minute 
[feet per minute]): Traverse (ut), traverse reference point 
(utr), and reference point during sampling (usr).
    (3) Calculate the corrected average sampling velocity 
(us) by applying Equation 2:
[GRAPHIC] [TIFF OMITTED] TR11SE98.003

    (4) Calculate the average flow rate (Qs) in cubic meters 
per minute (cubic feet per minute) by applying Equation 3:
[GRAPHIC] [TIFF OMITTED] TR11SE98.004

Where

A=Duct cross-sectional area, (square meters [square feet]
(5) Correct the flow rate to dry standard conditions (Qds) by 
applying Equation 4. Assume the static pressure to be atmospheric and 
the molar density correction factor to be 1.0
[GRAPHIC] [TIFF OMITTED] TR11SE98.005

Where

Ts=289 K (520 R)
TS=273 K (460 R)
H=Percent moisture-100
=0.02

    (6) Calculate the average total gaseous non-methane organic carbon 
for each duplicate sample run analyzed.
    (7) Calculate the grams (pounds) of VOC as CH2 emitted 
per start (normalized to 0.9 kilograms [2 pounds] of charcoal) for each 
run using Equation 5:
[GRAPHIC] [TIFF OMITTED] TR11SE98.006

Where

E=Emissions of VOC per start for each test run (grams VOC/start [pounds 
VOC/start])
A=Hydrocarbon molecular weight
=14.0268 grams per gram-mole (14.0268 pounds per pound-mole)
B=Carbon number
  =1
C=Average concentration for each duplicate run of total gaseous 
nonmethane organic compounds as CO2 (parts per million, from 
lab analysis sheet)
D=Sampling duration
  =25 minutes
d=Molar density of gas at standard conditions
  =42.33 gram-mole per cubic meter (0.0026353 pound-mole per cubic foot)
N=Normalized mass (0.9 kilograms [2 pounds])
M=Mass of charge (kilograms [pounds])

    (8) Calculate the average VOC emissions for each lighter material 
tested. Identify and discard statistical outliers. Note a minimum of 
five valid results are required for a determination. This procedure for 
eliminating an outlier may only be performed once for each lighter 
material tested.
    (9) Using Equation 6, calculate the resultant VOC emissions per 
start (Er) and determine if it is less than or equal

[[Page 314]]

to the 9 grams VOC per start emission limit.
[GRAPHIC] [TIFF OMITTED] TR11SE98.007

Where

ei=Average emissions of VOC per start from the charcoal 
lighter material being evaluated (grams VOC/start [pounds VOC/start] 
expressed as CH2)
eep=Average reference VOC emissions per start from the 
ignition by electric probe (grams VOC/start [pounds VOC/start] expressed 
as CH2)
  =0 grams VOC/start (0 pounds VOC/start) for treated or impregnated 
charcoal
Eb=Standard baseline VOC emissions per start from the 
ignition by electric probe (expressed as CH2)
  =0 grams VOC/start (0 pounds VOC/start) for treated or impregnated 
charcoal
  =3.6 grams VOC/start (0.008 pounds VOC/start) for all other charcoal 
lighter material

    (l) Recordkeeping. A record of the following charcoal lighter 
material compliance test information shall be kept for at least 5 years:
    (1) Real time temperature and continuous organic emissions monitor 
readings from continuous chart recorder and/or manual reading of 
temperatures and the continuous organic emissions monitor output.
    (2) A description of quality assurance/quality control (QA/QC) 
procedures followed for all measuring equipment and calibration test 
data.
    (3) A description of QA/QC procedures followed for all sampling and 
analysis equipment and calibration test data.
    (4) Time and quantity of blanks and ambient air samples.
    (5) Chain of custody for samples.
    (6) Labeled directions.
    (7) Field notes and data sheets.
    (8) Calculation/averaging sheets/printouts.
    (9) Sample (in its normal package from the same lot) of barbecue 
charcoal and lighter material used for testing.
    (10) Formulation of lighter material tested (indicate if the 
information is to be handled confidentially).
    (11) Photographs documenting charcoal surface ash coverage.
    (m) Quality Assurance/Quality Control (QA/QC) Requirements. The QA/
QC guidelines in the EPA's Quality Assistance Handbook (EPA 600.4-77-
027b) shall be followed. In addition, the following procedures shall be 
used:
    (1) A blank sample for VOC shall be performed once each day, during 
the start period of one of the lighter materials, using the integrated 
VOC sampling apparatus.
    (2) An ambient air sample for VOC shall be taken once each day, 
during the start period of one of the lighter materials, using the 
integrated VOC sampling apparatus with Nupro[Delta] 2 micron filters.
    (3) Traceability certificates shall be provided for all calibration 
gases used for the continuous organic emissions monitor and integrated 
VOC analysis.
    (4) Grill temperature probe shall be calibrated using the procedures 
in ASTM Method E220-86 (incorporated by reference as specified in United 
States Sec. 59.213).
    (5) Supply documentation for place of purchase ( or origin if 
experimental) and chain of custody for lighter material tested. 
Documentation to be included for both treated and impregnated charcoal.
    (6) Supply documentation for place of purchase and chain of custody 
for untreated charcoal.

[63 FR 48815, Sept. 11, 1998; 63 FR 52319, Sept. 30, 1998]



Sec. 59.209  Recordkeeping and reporting requirements.

    (a) The distributor that is named on the product label shall 
maintain the records specified in paragraphs (a)(1) and (a)(2) of this 
section, unless the manufacturer or importer has submitted to the 
Administrator a written certification that the manufacturer or importer 
will maintain the records for the distributor in accordance with 
paragraph (a)(3) of this section. If no distributor is named on the 
label, the manufacturer or importer must maintain the specified records. 
The records must be retained for at least 3 years and must be in a form 
suitable and readily available for inspection and review.

[[Page 315]]

    (1) Records or formulations being manufactured or imported on or 
after December 10, 1998 for all consumer products subject to 
Sec. 59.213(a), or December 10, 1999 for all consumer products subject 
to Sec. 59.203(c) and
    (2) Accurate records for each batch of production, starting on 
December 10, 1998 for all consumer products subject to Sec. 59.203(a) or 
December 10, 1999 for all consumer products subject to Sec. 59.203(c), 
of the weight-percent and chemical composition of the individual product 
constituents.
    (3) By providing this written certification to the Administrator, 
the certifying manufacturer accepts responsibility for compliance with 
the recordkeeping requirements in paragraphs (a)(1) and (a)(2) of this 
section with respect to any products covered by the written 
certification. Failure to maintain the required records may result in 
enforcement action by the EPA against the certifying manufacturer in 
accordance with the enforcement provisions applicable to violations of 
these provisions by regulated entities. The certifying manufacturer may 
revoke the written certification by sending a written statement to the 
Administrator and the regulated entity giving at least 90 days notice 
that the certifying manufacturer is rescinding acceptance of 
responsibility for compliance with the recordkeeping requirements listed 
in this paragraph. Upon expiration of the notice period, the regulated 
entity must assume responsibility for maintaining the records specified 
in this paragraph. Written certifications and revocation statements, to 
the Administrator from the certifying manufacturer shall be signed by 
the responsible official of the certifying manufacturer, provide the 
name and address of the certifying manufacturer, and be sent to the 
appropriate EPA Regional Office at the addresses listed in Sec. 59.210 
of this subpart. Such written certifications are not transferable by the 
manufacturer.
    (b) If requested by the Administrator, product VOC content must be 
demonstrated to the Administrator's satisfaction to comply with the VOC 
content limits presented in Sec. 59.203(a).
    (c) Each manufacturer or importer subject to the provisions of 
Sec. 59.203(d) shall maintain records specified in either paragraph 
(c)(1) or (c)(2) of this section for each charcoal lighter material.
    (1) Test report from each certification test performed as specified 
in Sec. 59.208(b) and all information and data specified in 
Sec. 59.208(l); or
    (2) Records of emission testing, which was performed by a method 
determined by the Administrator to be an acceptable alternative to that 
described in Sec. 59.208, previously submitted to a State or local 
regulatory agency.
    (d) The distributor that is named on the product label, or if no 
distributor is named on the label, the manufacturer or importer, shall 
submit by the applicable compliance date, or within 30 days after 
becoming a regulated entity, a one-time Initial Notification Report 
including the information specified in paragraphs (d)(1) through (d)(5) 
of this section.
    (1) Company name;
    (2) Name, title, phone number, address, and signature or certifying 
company official;
    (3) A list of product categories and subcategories subject to 
Sec. 59.203 for which the company is currently the regulated entity;
    (4) A description of date coding systems, clearly explaining how the 
date of manufacture is marked on each sales unit of subject consumer 
products; and
    (5) The name and location of the designated recordkeeping agent, if 
the records specified in paragraphs (a)(1) and (a)(2) are to be 
maintained by the manufacturer.
    (e) If a regulated entity changes the date coding system reported 
according to paragraph (d)(4) of this section, the regulated entity 
shall notify the Administrator of such changes within 30 days following 
the change.
    (f) If requested by the Administrator, the following information 
shall be made available within 30 days after receiving the request:
    (1) Location of facility(ies) manufacturing, importing, or 
distributing subject consumer products;
    (2) A list of product categories and subcategories, as found in 
tables 1 and 2 of this subpart, that are manufactured, imported, or 
distributed at each facility; and

[[Page 316]]

    (3) Location where VOC content records are kept for each subject 
consumer product.
    (g) Each manufacturer or importer subject to the innovative product 
provisions in Sec. 49.204 shall submit notifications as indicated in 
Sec. 59.204(d) and (e).



Sec. 59.210  Addresses of EPA Regional Offices.

    All requests, reports, submittals, and other communications to the 
Administrator pursuant to this regulation shall be submitted to the 
Regional Office of the EPA which serves the State or territory in which 
the corporate headquarters of the regulated entity resides. These areas 
are indicated in the following list of EPA Regional Offices:

    EPA Region I (Connecticut, Maine, Massachusetts, New Hampshire, 
Rhode Island, Vermont), Director, Office of Ecosystem Protection, J.F.K. 
Federal Building, Boston, MA 02203-2211.
    EPA Region II (New Jersey, New York, Puerto Rico, Virgin Islands), 
Director, Division of Environmental Planning and Protection, 290 
Broadway, New York, NY 10007.
    EPA Region III (Delaware, District of Columbia, Maryland, 
Pennsylvania, Virginia, West Virginia), Director, Air, Radiation, and 
Toxics Division, 841 Chestnut Building, Philadelphia, PA 19107.
    EPA Region IV (Alabama, Florida, Georgia, Kentucky, Mississippi, 
North Carolina, South Carolina, Tennessee), Director, Air, Pesticides, 
and Toxics Management Division, 61 Forsyth Street, Atlanta, GA 30303.
    EPA Region V (Illinois, Indiana, Michigan, Minnesota, Ohio, 
Wisconsin), Director, Air and Radiation Division, 77 West Jackson Blvd., 
Chicago, IL 60604-3507.
    EPA Region VI (Arkansas, Louisiana, New Mexico, Oklahoma, Texas), 
Director, Multimedia Planning and Permitting Division, 1445 Ross Avenue, 
Dallas, TX 75202-2733.
    EPA Region VII (Iowa, Kansas, Missouri, Nebraska), Director, Air, 
RCRA, and Toxics Division, 726 Minnesota Avenue, Kansas City, KS 66101.
    EPA Region VIII (Colorado, Montana, North Dakota, South Dakota, 
Utah, Wyoming), Director, Office of Pollution Prevention, State, and 
Tribal Assistance, 999 18th Street, Suite 500, Denver, Colorado 80202-
2466.
    EPA Region IX (American Samoa, Arizona, California, Guam, Hawaii, 
Nevada) Director, Air Divisions, 75 Hawthorne Street, San Francisco, CA 
94105.
    EPA Region X (Alaska, Oregon, Idaho, Washington), Director, Office 
of Air Quality, 1200 Sixth Avenue, Seattle, WA 98101.



Sec. 59.211  State authority.

    (a) The provisions in this regulation shall not be construed in any 
manner to preclude any State or political subdivision thereof from:
    (1) Adopting and enforcing any emission standard or limitation 
applicable to a regulated entity.
    (2) Requiring the regulated entity to obtain permits, licenses, or 
approvals prior to initiating construction, modification, or operation 
of a facility for manufacturing a consumer product.
    (b) [Reserved]



Sec. 59.212  Circumvention.

    No regulated entity subject to these standards shall alter, destroy, 
or falsify any record or report to conceal what would otherwise be 
noncompliance with these standards. Such concealment includes, but is 
not limited to refusing to provide the Administrator access to all 
required records and date-coding information, altering the percent VOC 
content of a product batch, or altering the results of any required 
performance tests.



Sec. 59.213  Incorporations by reference.

    (a) The materials listed in this section are incorporated by 
reference in the paragraphs noted in Sec. 59.207. These incorporations 
by reference were approved by the Director of the Federal Register in 
accordance with 5 U.S.C. 552(a) and 1 CFR part 51. These materials are 
incorporated as they exist on the date of the approval, and notice of 
any changes in these materials will be published in the Federal 
Register. The materials are available for purchase at the corresponding 
addresses noted below, and all are available for inspection at the 
Office of the Federal Register, 800 North Capitol Street, NW., Suite 
700, Washington, DC 20408, at the Air and Radiation Docket and 
Information Center, U.S. EPA, 401 M St., SW., Washington, DC 20460, and 
at the EPA Library (MD-35), U.S. EPA, Research Triangle Park, NC 27711.
    (b) The materials listed below are available for purchase from at 
least one of the following addresses: American Society for Testing and 
Materials (ASTM), 1916 Race Street, Philadelphia, PA, 19103; SCAQMD 
Subscription Services, P.O. Box 4932; 21865 Copley

[[Page 317]]

Drive, Diamond Bar, CA 91765-0932; or University Microfilms 
International, 300 North Zeeb Road, Ann Arbor MI, 48106.
    (1) ASTM Method E220-86 Standard Method for Calibration of 
Thermocouples by Comparisons Techniques, incorporation by reference 
(IBR) approved for Sec. 59,208(m)(4).
    (2) ASTM Method E380-82 Metric Practice, IBR approved for 
Sec. 59.208(k).
    (3) SCAQMD Method 25.1, March 1989 Determination of Total Gaseous 
Non-Methane Organic Emissions as Carbon (amended February 26, 1991) IBR 
approved for Sec. 59.208(g)(2).



Sec. 59.214  Availability of information and confidentiality

    (a) Availability of information. Specific reports or records 
required by this subpart are not available to the public. The 
Administrator will, upon request, provide information as to the 
compliance status of a product or regulated entity.
    (b) Confidentiality. All confidential business information entitled 
to protection under section 114(c) of the CAA that must be submitted or 
maintained by a regulated entity pursuant to this section shall be 
treated in accordance with 40 CFR part 2, Subpart B.

      Table 1 to Subpart C.--VOC Content Limits by Product Category
------------------------------------------------------------------------
                                                            VOC content
                    Product category                      limit (weight-
                                                           percent VOC)
------------------------------------------------------------------------
Air fresheners:
    Single-phase........................................              70
    Double-phase........................................              30
    Liquids/pump sprays.................................              18
    Solids/gels.........................................               3
Automotive windshield washer fluid......................              35
Bathroom and tile cleaners:
    Aerosols............................................               7
    All other forms.....................................               5
Carburetor and choke cleaners...........................              75
    Cooking sprays--aerosol.............................              18
Dusting aids:
    Aerosols............................................              35
    All other forms.....................................               7
Engine degreasers.......................................              75
Fabric protectants......................................              75
Floor polishes/waxes:
    Products for flexible flooring materials............               7
    Products for nonresilient flooring..................              10
    Wood floor wax......................................              90
Furniture maintenance products-aerosol..................              25
General purpose cleaners................................              10
Glass cleaners:
    Aerosols............................................              12
    All other forms.....................................               8
Hairsprays..............................................              80
Hair mousses............................................              16
Hair Styling gels.......................................               6
Household adhesives:
    Aerosols............................................              75
    Contact.............................................              80
    Construction and panel..............................              40
    General purpose.....................................              10
    Structural waterproof...............................              15
Insecticides:
    Crawling bug........................................              40
    Flea and tick.......................................              25
    Flying bug..........................................              35
    Foggers.............................................              45
    Lawn and Garden.....................................              20
Laundry prewash:
    Aerosols/solids.....................................              22
    All other forms.....................................               5
Laundry starch products.................................               5
Nail polish removers....................................              85
Oven cleaners:
    Aerosols/pump.......................................               8
    Liquids.............................................               5
Shaving creams..........................................               5
------------------------------------------------------------------------


[[Page 318]]


 Table 2 to Subpart C.--HVOC \1\ Content Limits for Underarm Deodorants
                      and Underarm Antiperspirants
------------------------------------------------------------------------
                                                           Percent HVOC
                                                           content limit
                    Product category                         (weight-
                                                           percent HVOC)
------------------------------------------------------------------------
Underarm antiperspirants--aerosol.......................              60
Underarm deodorants--aerosol............................              20
------------------------------------------------------------------------
\1\ High-volatility organic compound (HVOC) are VOC with vapor pressure
  greater than 80 millimeters of mercury at 20 degrees Celsius.


[[Page 319]]

               Appendix A to Subpart C of Part 59--Figures
      [GRAPHIC] [TIFF OMITTED] TR11SE98.008
      

[[Page 320]]


[GRAPHIC] [TIFF OMITTED] TR11SE98.009


[[Page 321]]


[GRAPHIC] [TIFF OMITTED] TR11SE98.010


[[Page 322]]


[GRAPHIC] [TIFF OMITTED] TR11SE98.011


[[Page 323]]