<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="billres.xsl"?>
<!DOCTYPE bill PUBLIC "-//US Congress//DTDs/bill.dtd//EN" "bill.dtd">
<bill bill-stage="Reported-in-House" bill-type="olc" dms-id="H3918EBB724F24018BD524E9E2A2E0AE1" key="H" public-private="public"><metadata xmlns:dc="http://purl.org/dc/elements/1.1/">
<dublinCore>
<dc:title>116 HR 5758 RH: Ceiling Fan Improvement Act of 2020</dc:title>
<dc:publisher>U.S. House of Representatives</dc:publisher>
<dc:date>2020-12-08</dc:date>
<dc:format>text/xml</dc:format>
<dc:language>EN</dc:language>
<dc:rights>Pursuant to Title 17 Section 105 of the United States Code, this file is not subject to copyright protection and is in the public domain.</dc:rights>
</dublinCore>
</metadata>
<form>
<distribution-code display="yes">IB</distribution-code><calendar display="yes">Union Calendar No. 511</calendar><congress display="yes">116th CONGRESS</congress><session display="yes">2d Session</session><legis-num display="yes">H. R. 5758</legis-num><associated-doc role="report" display="yes">[Report No. 116–626]</associated-doc><current-chamber>IN THE HOUSE OF REPRESENTATIVES</current-chamber><action display="yes"><action-date date="20200205">February 5, 2020</action-date><action-desc><sponsor name-id="G000558">Mr. Guthrie</sponsor> (for himself and <cosponsor name-id="S001145">Ms. Schakowsky</cosponsor>) introduced the following bill; which was referred to the <committee-name committee-id="HIF00">Committee on Energy and Commerce</committee-name></action-desc></action><action display="yes"><action-date date="20201208">December 8, 2020</action-date><action-desc>Reported from the <committee-name committee-id="HIF00">Committee on Energy and Commerce</committee-name>; committed to the Committee of the Whole House on the State of the Union and ordered to be printed</action-desc></action><action><action-desc><pagebreak></pagebreak></action-desc></action><legis-type>A BILL</legis-type><official-title display="yes">To amend the Energy Policy and Conservation Act to make technical corrections to the energy conservation standard for ceiling fans, and for other purposes.<pagebreak></pagebreak></official-title></form><legis-body id="HC23E15CAD9FC4A52A6716F235D3D94F2" style="OLC"><section id="H40FEB7F83F174B05BB3B5F82F7653A85" section-type="section-one"><enum>1.</enum><header>Short title</header><text display-inline="no-display-inline">This Act may be cited as the <quote><short-title>Ceiling Fan Improvement Act of 2020</short-title></quote>.</text></section><section id="HC936D253D4BB4421977A38E2C43F9AEE"><enum>2.</enum><header>Modifications to the ceiling fan energy conservation standard</header><subsection id="H76D2EEC1409942C1876C1820DED5ED05"><enum>(a)</enum><header>In general</header><text>Section 325(ff)(6) of the Energy Policy and Conservation Act (<external-xref legal-doc="usc" parsable-cite="usc/42/6295">42 U.S.C. 6295(ff)(6)</external-xref>) is amended by adding at the end the following:</text><quoted-block id="HBF70F46F7D064DA7A674633BAC56389F" style="OLC"><subparagraph id="HF1B24186E6934F9BAB54FB4B1630F54A" indent="up2"><enum>(C)</enum><clause commented="no" display-inline="yes-display-inline" id="H81C0007A049549C7807EF23785BFBE5F"><enum>(i)</enum><text>Large-diameter ceiling fans manufactured on or after January 21, 2020, shall—</text><subclause id="H7EF7E694522E41DDB8B8252E15F4BB52" indent="up1"><enum>(I)</enum><text>not be required to meet minimum ceiling fan efficiency in terms of ratio of the total airflow to the total power consumption as described in the final rule titled <quote>Energy Conservation Program: Energy Conservation Standards for Ceiling Fans</quote> (82 Fed. Reg. 6826 (January 19, 2017)); and</text></subclause><subclause id="HFE5DC520F5664D08A5B91EA9837C44C4" indent="up1"><enum>(II)</enum><text>have a CFEI greater than or equal to—</text><item id="H99873C732D074AD7B336F4469B6F0A39"><enum>(aa)</enum><text>1.00 at high speed; and</text></item><item id="HC47828D2EC834F02805D3A29AA87522F"><enum>(bb)</enum><text>1.31 at 40 percent speed or the nearest speed that is not less than 40 percent speed.</text></item></subclause></clause><clause id="H25E2609969B547A9A0493CE50D083FC7" indent="up1"><enum>(ii)</enum><text>For purposes of this subparagraph, the term <term>CFEI</term> means the Fan Energy Index for large-diameter ceiling fans, calculated in accordance with ANSI/AMCA Standard 208–18 titled <quote>Calculation of the Fan Energy Index</quote>, with the following modifications:</text><subclause id="H5EDD8268444C4F91A34F6DED56AE78AF"><enum>(I)</enum><text>Using an Airflow Constant (Q<subscript>0</subscript>) of 26,500 cubic feet per minute.</text></subclause><subclause id="HC07079FB58874D0299F8CBD1B7170B3C"><enum>(II)</enum><text>Using a Pressure Constant (P<subscript>0</subscript>) of 0.0027 inches water gauge.</text></subclause><subclause id="H5ABA833253304D07A17370D7FF4F9817"><enum>(III)</enum><text>Using a Fan Efficiency Constant (η<subscript>0</subscript>) of 42 percent.</text></subclause></clause></subparagraph><after-quoted-block>.</after-quoted-block></quoted-block></subsection><subsection id="H8BB694CE2FAC49CC9FC3B80FEB718597"><enum>(b)</enum><header>Revision</header><text>For purposes of section 325(m) of the Energy Policy and Conservation Act (<external-xref legal-doc="usc" parsable-cite="usc/42/6295">42 U.S.C. 6295(m)</external-xref>), the standard established in section 325(ff)(6)(C) of such Act (as added by subsection (a) of this section) shall be treated as if such standard was issued on January 19, 2017.</text></subsection></section></legis-body><endorsement display="yes"><action-date>December 8, 2020</action-date><action-desc>Committed to the Committee of the Whole House on the State of the Union and ordered to be printed</action-desc></endorsement></bill> 

